MX-FXX2  SIMULATIONS, FAX SOFTWARE SWITCH  5 – 10
Check item
The number in < > indicates the line.
 
66-4
Purpose
Operation test/Check
Function (Purpose) Used to send the selected signals to the
line and the main unit speaker. (Send level:
max.) 
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-04, the screen on the
right is displayed. (Default, left upper selected.)
* Use [
↑] [↓] buttons to switch the send mode select page.
When the selected item is the top (last)item, [
↑] [↓] buttons
gray out. (The highlighted section of the set value is
switched and displayed on the set setting area.)
When [
↑] [↓] buttons gray out, they are disabled.
2)
When a button of a signal to be sent is selected, it is high-
lighted and the previously set button is shifted to the normal
display.
* Only one signal to be sent can be selected.
3)
When [EXECUTE] button is pressed, it is highlighted and sig-
nals are sent.
4)
To end signal send:
When [EXECUTE] button is pressed, it is highlighted and sig-
nal send is interrupted.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
<Signal send table>
Page1
Page2
 
66-5
Purpose
Operation test/Check
Function (Purpose) Used to send the selected signal to the line
and the main unit speaker. (Send level: Soft
SW setting) (For the kinds of send signals,
refer to PART1 and PART2 of SIM66-04.)
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-05, the following
screen is displayed. (Default, left upper selected)
* Use  [
↑] [↓] buttons to switch the send mode select page.
When the selected item is the top (last)item, [
↑] [↓] buttons
gray out. (The highlighted section of the set value is
switched and displayed on the set setting area.)
When [
↑] [↓] buttons gray out, they are disabled.
2)
When a button of a signal to be sent is selected, it is high-
lighted and the previously set button is shifted to the normal
display.
* Only one signal to be sent can be selected.
3)
When [EXECUTE] button is pressed, it is highlighted and sig-
nals are sent.
4)
To end signal send:
* When [EXECUTE] button is pressed, it is highlighted and
signal send is interrupted.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display
returns to the sub number entry screen.
Check memory item
Remark
1
All Memory Device Check (once)
All the items are checked 
once. 
2
MFP SRAM (once)
Check only once
3
MFP SRAM (repeat)
Repeat check
4
MFP FLASH + OP.FLASH (once)
Check only once
5
MFP FLASH + OP.FLASH (repeat)
Repeat check
6
MODEM EEPROM <1> (once)
Check only once in LINE1
7
MODEM EEPROM <1> (repeat)
Repeat check in LINE1
8
MODEM SDRAM <1> (once)
Check only once in LINE1
9
MODEM SDRAM<1>(repeat)
Repeat check in LINE1
NOSIGNAL
33.6 V34
31.2 V34
28.8 V34
26.4 V34
24.0 V34
21.6 V34
19.2 V34
16.8 V34
14.4 V34
12.0 V34
9.6 V34
7.2 V34
4.8 V34
2.4 V34
14.4 V33
12.0 V33
14.4 V17
12.0 V17
9.6 V17
7.2 V17
9.6 V29
7.2 V29
4.8 V27t
2.4 V27t
0.3 FLG
CED 2100
CNG 1100
0.3 V21
ANSam
RINGER
No RBT
SIMULATION NO.66-03
CLOSE
TEST
FAX PWB MEMORY CHECK
0
ALL Memory Device Check(once)
MFP SRAM(once)
MFP SRAM(repeat)
MFP FLASH+OP.FLASH(once)
MFP FLASH+OP.FLASH(repeat)
MODEM EEPROM<1>(once)
MODEM EEPROM<1>(repeat)
MODEM SDRAM<1>(once)
MODEM SDRAM<1>(repeat)
1/1
DP MAKE
DP BRK
NO MSG
SIMULATION NO.66-04
CLOSE
TEST
SIGNAL OUTPUT CHECK.(LEVEL MAX)
0
EXECUTE
1/2
NOSIGNAL
33.6V34
28.8V34
31.2V34
26.4V34
24.0V34
19.2V34
21.6V34
16.8V34
14.4V34
9.6V34
12.0V34
7.2V34
4.8V34
14.4V33
2.4V34
12.0V33
14.4V17
9.6V17
12.0V17
7.2V17
9.6V29
4.8V27t
7.2V29
2.4V27t
0.3FLG
CNG1100
CED2100
0.3V21
AVSam
No RBT
RINGER
SIMULATION NO.66-05
CLOSE
TEST
SIGNAL OUTPUT CHECK.(SOFT SW.)
0
EXECUTE
1/2
NOSIGNAL
33.6V34
28.8V34
31.2V34
26.4V34
24.0V34
19.2V34
21.6V34
16.8V34
14.4V34
9.6V34
12.0V34
7.2V34
4.8V34
14.4V33
2.4V34
12.0V33
14.4V17
9.6V17
12.0V17
7.2V17
9.6V29
4.8V27t
7.2V29
2.4V27t
0.3FLG
CNG1100
CED2100
0.3V21
AVSam
No RBT
RINGER
MX-FXX2  SIMULATIONS, FAX SOFTWARE SWITCH  5 – 11
 
66-6
Purpose
Data output/Check
Function (Purpose) Used to print the confidential registration
check table (BOX NO., BOX name, pass-
code. (If there is no confidential registra-
tion, no print is made.)
Section
FAX
Item
Data (Confidential passcode)
Operation/Procedure
1)
When [EXECUTE] button is pressed, it is highlighted and the
confidential checkable is printed.
* If there is no confidential registration, no print is made even
though [EXECUTE] key is pressed.
2)
After completion of printing, [EXECUTE] button returns to the
normal display.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
* When [C], [CA], [SYSTEM SETTINGS], or [EXECUTE] key is
pressed during printing, the operation is interrupted.
 
66-7
Purpose
Data output/Check
Function (Purpose) Used to output all image data saved in the
image memory. (Confidential data are also
outputted.)
Section
FAX
Item
Data (Image data)
Operation/Procedure
1)
When [EXECUTE] button is pressed, it is highlighted and all
image data saved in the image memory are outputted.
* The confidential data are also outputted.
After completion of printing, the image data are not cleared.
* If there is no image memory, no print is made though [EXE-
CUTE] button is pressed.
2)
After completion of printing, [EXECUTE] button returns to the
normal display.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
* When [C], [CA], [SYSTEM SETTINGS], or [EXECUTE] key is
pressed during printing, the operation is interrupted.
 
66-8
Purpose
Operation test/Check
Function (Purpose) Used to send the selected sound mes-
sages to the line and the speaker. (Send
level: Max.)
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-08, the following
screen is displayed. (Default, left upper selected)
2)
When the sound message button to be sent is selected, it is
highlighted and the previously set button returns to the normal
display.
* Only one sound message to be sent can be selected.
* When [EXECUTE] button is pressed, it is highlighted and a
sound message is sent.
* When [EXECUTE] button is pressed, it is returns to the nor-
mal display and sending a sound message is interrupted.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
<Sound message table>
 
66-9
Purpose
Operation test/Check
Function (Purpose) Used to send the selected sound message
to the line and the speaker. (Send level:
max.) 
* For details of sound messages, refer to
the sound message table of SIM66-08.
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-09, the following
screen is displayed. (Default, left upper setting)
2)
When a button of a sound message to be sent is selected, it is
highlighted and the previously set button returns to the normal
display.
* Only one sound message to be sent can be selected.
3)
When [EXECUTE] button is pressed, it is highlighted and a
sound message is sent.
4)
To end signal send:
When [EXECUTE] button is pressed, it is highlighted and sig-
nal send is interrupted.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
SIMULATION NO.66-06
CLOSE
TEST
PASS CODE PRINT OUT.
0
EXECUTE
SIMULATION NO.66-07
CLOSE
TEST
IMAGE MEMORY PRINTOUT.
0
EXECUTE
NONE (Mute)
PAUSE (Pause 
melody)
MESSAGE1 
(Message 1)
MESSAGE2 
(Message 2)
MESSAGE3 
(Message 3)
MESSAGE4 
(Message 4)
MESSAGE5 
(Massage 5)
MESSAGE6 
(Message 6)
ALARM (Alarm)
RINGER 
(Ringing sound 
(Speaker))
EXT.TEL.RING
ER (External 
telephone call)
SIMULATION NO.66-08
CLOSE
TEST
SMASSAGE OUTPUT CHECK.(LEVEL MAX)
0
EXECUTE
NONE
PAUSE
MESSAGE2
MESSAGE1
MESSAGE3
MESSAGE4
MESSAGE6
MESSAGE5
ALARM
RINGER
EXT.TEL.RINGER
MX-FXX2  SIMULATIONS, FAX SOFTWARE SWITCH  5 – 12
 
66-10
Purpose
Data clear
Function (Purpose) Used to clear all image data saved in the
FAX image memory. (The confidential data
are also cleared.)
Section
FAX
Item
Clear (Image data)
Operation/Procedure
1)
Press [EXECUTE] button.
[EXECUTE] button is highlighted and [YES] and [NO] buttons
become active.
2)
Press [YES] button.
The image memory is cleared. [YES] button is highlighted.
* When [NO] button is pressed, [EXECUTE] button returns to
the normal display and [YES] and [NO] buttons gray out.
* During clearing the image memory, [EXECUTE] and [YES]
buttons are highlighted.
The image memory can be cleared even if there is no image
data.
3)
After completion of clearing, press [CA] key to reboot the
machine.
 
66-11
Purpose
Operation test/Check
Function (Purpose) Used to send the selected signal at 300bps
to the line and the speaker. (Send level:
Max.)
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-11, the following
screen is displayed. (Default, left upper setting)
2)
When a button of a sound message to be sent is selected, it is
highlighted and the previously set button returns to the normal
display.
* Only one sound message to be sent can be selected.
3)
When [EXECUTE] button is pressed, it is highlighted and a
sound message is sent.
4)
To end signal send:
When [EXECUTE] button is pressed, it is highlighted and sig-
nal send is interrupted.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
<300bps send signal table>
 
66-12
Purpose
Operation test/Check
Function (Purpose) Used to send the selected signal at 300bps
to the line and the speaker. (Send level:
Soft SW setting) 
* For the kings of send signals at 300bps,
refer to SIM66-11, 300bps send signal
table.
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-12, the following
screen is displayed. (Default, left upper setting)
2)
When a button of a sound message to be sent is selected, it is
highlighted and the previously set button returns to the normal
display.
* Only one sound message to be sent can be selected.
3)
When [EXECUTE] button is pressed, it is highlighted and a
sound message is sent.
4)
To end signal send:
When [EXECUTE] button is pressed, it is highlighted and sig-
nal send is interrupted.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
 
66-13
Purpose
Setting
Function (Purpose) Used to register dial numbers for SIM66-
14/15/16, Dial test. (Up to 20 digits can be
registered.)
Section
FAX
Item
Data (Registration)
Operation/Procedure
1)
When the machine enters Simulation 66-13, the following
screen is displayed.
* The number saved in the memory is displayed in the column
of [PRESENT:]. (If there is no data, [-------] is displayed.)
SIMULATION NO.66-09
CLOSE
TEST
MASSAGE OUTPUT CHECK.(SOFT SW.)
0
EXECUTE
NONE
PAUSE
MESSAGE2
MESSAGE1
MESSAGE3
MESSAGE4
MESSAGE6
MESSAGE5
ALARM
RINGER
EXT.TEL.RINGER
SIMULATION NO.66-10
CLOSE
TEST
IMAGE MEMORY CLEAR.
0
EXECUTE
ARE YOU SURE?
YES
NO
NO SIGNAL
11111
11110
00000
010101
00001
SIMULATION" NO.66-11
CLOSE
TEST
300bps SIGNAL OUTPUT.(LEVEL MAX)
0
EXECUTE
NO SIGNAL
11111
00000
1110
010101
0001
SIMULATION NO.66-12
CLOSE
TEST
300bps SIGNAL OUTPUT (SOFT SW.)
0
EXECUTE
NO SIGNAL
11111
00000
1110
010101
0001
MX-FXX2  SIMULATIONS, FAX SOFTWARE SWITCH  5 – 13
2)
Enter a number with 10-key.
The entered number is displayed in the column of [NEW:].
After entering 20 digits, 10-key is disabled (no response). Only
[C] key is enabled. (10-key [0] to [9], [*], [#], [C] key (back by
one digit))
3)
When [SET] key is pressed after completion of entry, the
entered number is displayed (registered) in the column of
[PRESENT:]. The column of [NEW:] becomes blank.
* If the "NEW:" column is blank, SET is inactive. When a value
is entered to the "NEW:" column, it becomes active.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
 
66-14
Purpose
Adjustment
Function (Purpose) Used to execute the dial pulse (10PPS)
send test and to adjust the make time.
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-14, the following
screen is displayed.
* Enter the make time (0 to 15) with 10-key and press [OK]
button, and the entered make time is temporality saved.
* Enter the make time (0 to 15) with 10-key and press [EXE-
CUTE] button instead of [OK] button, and [EXECUTE] but-
ton is highlighted and the dial pulse is sent from the line in
the set make time.
2)
When [EXECUTE] button is pressed, it is highlighted and the
dial pulse is sent from the line in the set make time.
* The dial pulse in this example is up to 20 digits registered
with SIM66-13.
3)
To end the dial test, press [EXCUTE] button again. The button
returns to the normal display and the test is terminated.
Also when dialing the number is completed, [EXECUTE] but-
ton returns to the normal display and the test is terminated.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
 
66-15
Purpose
Adjustment
Function (Purpose) Used to execute the dial pulse (20PPS)
send test and to adjust the make time.
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-15, the following
screen is displayed.
* Enter the make time (0 to 15) with 10-key and press [OK]
button, and the entered make time is temporality saved.
* Enter the make time (0 to 15) with 10-key and press [EXE-
CUTE] button instead of [OK] button, and [EXECUTE] but-
ton is highlighted and the dial pulse is sent from the line in
the set make time.
2)
When [EXECUTE] button is pressed, it is highlighted and the
dial pulse is sent from the line in the set make time.
* The dial pulse in this example is up to 20 digits registered
with SIM66-13.
3)
To end the dial test, press [EXCUTE] button again. The button
returns to the normal display and the test is terminated.
Also when dialing the number is completed, [EXECUTE] but-
ton returns to the normal display and the test is terminated.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
 
66-16
Purpose
Adjustment
Function (Purpose) Used to execute the DTFM signal send test
and to adjust the send level.
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-16, the following
screen is displayed.
* Item A (High group frequency) and item B (High-Low group
frequency) are selected with [
↑] [↓] buttons. When the
selected item is the top (last) item, [
↑] [↓] buttons gray out.
(The highlighted section of the set value is switched and dis-
played on the set setting area.)
When [
↑] [↓] buttons gray out, they are disabled.
* Enter the High group or High - Low group (0 to 15) with 10-
key and press [OK] button. The set sign send level is tempo-
rality saved.
* Enter the single send level (0 to 15) with 10-key and press
[EXECUTE] button instead of [OK] button, and [EXECUTE]
button is highlighted and the dial pulse is sent from the line
by the setting of high group or low group.
2)
When [EXECUTE] button is pressed, it is highlighted and the
dial pulse signal is sent from the line by the setting of high/low
group of the signal send level.
SIMULATION NO.66-13
CLOSE
TEST
DIAL TEST NUMBER SETTING.
0
PRESENT:
NEW:
0123456789#
*
SET
SIMULATION NO.66-14
CLOSE
TEST
DIAL TEST(10PPS).
0
4
A:
0
15
: MAKE TIME[+29ms]
A:
4
OK
EXECUTE
SIMULATION NO.66-15
CLOSE
TEST
DIAL TEST(20PPS).
0
4
A:
0
15
: MAKE TIME[+9ms]
A:
4
OK
EXECUTE
Page of 80
Display

Click on the first or last page to see other MX-FXX2 (serv.man2) service manuals if exist.