DOWNLOAD Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) Service Manual ↓ Size: 29.56 MB | Pages: 127 in PDF or view online for FREE

Model
MX-C250 MX-C250E MX-C250F MX-C250FE MX-C250FR MX-C300F MX-C300W MX-C300WE MX-C300A MX-C300WR (serv.man6)
Pages
127
Size
29.56 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual (Revised May 2016).
File
mx-c250-mx-c250e-mx-c250f-mx-c250fe-mx-c250fr-mx-c.pdf
Date

Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) Service Manual ▷ View online

MX-C250  SIMULATION  6 – 39
44-21
Purpose
:
Adjustment/Setup
Function (Purpose)
Used to set the half tone process control
target.
Section
Process
Operation/Procedure
1) When pressed [OK]/[START] key, the adjustment is executed
and the results are displayed.
In case of abnormal end, “ERROR” and the following error
codes are displayed.
44-22
Purpose
:
Operation data display
Function (Purpose)
Used to display the toner patch density
level in the half tone process control opera-
tion.
Section
Process
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
The the toner patch density level which is created at the half
tone process control operation is displayed.  
44-24
Purpose
:
Operation data display
Function (Purpose)
Used to display the correction target and
the correction level in the half tone process
control operation.
Section
Process
Operation/Procedure
1) Select the display category with 10 keys.
2) Select a target adjustment color with [OK]/[START] key.
44-25
Purpose
:
Setting
Function (Purpose)
Used to set the calculating conditions of the
correction value for the half tone process
control.
Section
Process
Operation/Procedure
1) Select the display category with 10 keys.
2) Select a target adjustment color with [OK]/[START] key.
3) Enter the set value with 10 keys.
4) Press [OK]/[START] key. 
NOTE:
Set the items to the default values unless a change is spe-
cially required.
44-26
Purpose
:
Adjustment/Setup
Function (Purpose)
Used to execute the half tone process con-
trol compulsorily.
Section
Process
Operation/Procedure
Press [OK]/[START] key.
The half tone process control is performed and the operation data
are displayed.
44-27
Purpose
:
Data clear
Function (Purpose)
Used to clear the correction data of the half
tone process control.
Section
Process
Operation/Procedure
1) Press [OK]/[START] key.
The correction data of the half tone process control are cleared.
Item/Display
Content
Range
K/C/M/Y
#1 - #17
Half-tone correction val-
ues in each color
0 - 255
Error code
Content
CL_SEN_ADJ_ERR
Color image density sensor sensi-
tivity adjustment error *
BK_SEN_ADJ_ERR
Black image density sensor 
sensitivity adjustment error *
[YMCK]
High density process control error 
[YMCK]
OTHER
Other errors
Item/Display
Content
K/C/M/Y _n
Patch data display(n=1 - 13)
K/C/M/Y _B1
Belt substrate data (START)
K/C/M/Y _B2
Belt substrate data (LAST)
No.
Item/Display
Content
1
DITHER RAW VALUE
Half tone process control reference dither 
value (Previous adjustment)
2
SENSOR_TARGET
Half tone process control reference value
3
S_VALUE
Half tone process control correction value
4
BEFORE S_VALUE
Previous half tone process control correction 
value
5
CALIB VALUE
Automatic calibration reference value
6
CALIB VALUE PRC
Automatic calibration reference value (half 
tone process control)
No.
Item
Content
Min
Max
Default 
value
1
HIGHT-
LIGHT 
LIMIT K
Correction limit value of 
the highlight correction 
amount
0
128
20
2
MAX LIMIT 
K
Correction limit value of 
the highest density value
0
128
20
3
HIGHT-
LIGHT 
LIMIT C
Correction limit value of 
the highlight correction 
amount
0
128
20
4
MAX LIMIT 
C
Correction limit value of 
the highest density value
0
128
20
5
HIGHT-
LIGHT 
LIMIT M
Correction limit value of 
the highlight correction 
amount
0
128
20
6
MAX LIMIT 
M
Correction limit value of 
the highest density value
0
128
20
7
HIGHT-
LIGHT 
LIMIT Y
Correction limit value of 
the highlight correction 
amount
0
128
20
8
MAX LIMIT 
Y
Correction limit value of 
the highest density value
0
128
20
ITEMS
DISPLAY ITEMS
CONTENT
RANGE
K/C/M/Y
#1 - #17
Half-tone correction val-
ues in each color
0 - 255
Display
Contents
CL_SEN_ADJ_ERR
Color sensor adjustment error
BK_SEN_ADJ_ERR
Black sensor adjustment error
[YMCK]
High density process control [YMCK] error
OTHER
Other error
MX-C250  SIMULATION  6 – 40
44-28
Purpose
:
Adjustment/Setup
Function (Purpose)
Used to set the process control execution
conditions.
Section
Process
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
NOTE: Set the items to the default values unless a change is spe-
cially required.
Mode
Item/Display
Content
Setting range
Default 
value
1
Process control 
Enable/Disable 
setting
INITIAL
YES
When warm-up after clearing the 
counter of the OPC drum and the 
developer unit
Enable
0 - 1
0
0
NO
Disable
1
2
SW  ON
When supplying the power (when 
clearing shut-off.)
Color process con-
trol Enable
0 - 3
0
3
Process control Dis-
able
1
BK process control 
Enable
2
Pixel count judg-
ment (Judgement is 
based on the setting 
value of item K, L.)
3
3
TIME
After passing the specified time from 
leaving READY continuously (Time 
can be changed by INTERVAL TIME)
Color process con-
trol Enable
0 - 3
0
3
Process control Dis-
able
1
BK process control 
Enable
2
Pixel count judg-
ment
(Judgement is 
based on the setting 
value of item K, L.)
3
4
HUM_LIMIT
HUM judgment is made when turning 
ON the power and after passing 
TIME.
Color process con-
trol Enable
0 - 2
0
0
Process control Dis-
able
1
BK process control 
Enable
2
5
Process control 
Enable/Disable 
setting
HUM
The temperature and humidity in side 
the machine are monitored only dur-
ing a job for every 2hours (set by item 
N). When the changes in the temper-
ature and the humidity are greater 
than the specified level (the set value 
of item O) in comparison with the pre-
vious process control.
Color process con-
trol Enable
0 - 2
0
0
Process control Dis-
able
1
BK process control 
Enable
2
6
REV1
YES
The accumulated traveling distance 
of BK or M position OPC unit  
reaches the specified level after turn-
ing the power.
Enable
0 - 1
0
0
NO
Inhibit
1
7
REV2_BK
YES
The accumulated traveling distance 
of BK position OPC drum unit 
reaches the specified level from exe-
cution of the previous density correc-
tion.
Enable
0 - 1
0
0
NO
Inhibit
1
8
REV2_CL
YES
The accumulated traveling distance 
of M position OPC drum unit reaches 
the specified level from execution of 
the previous density correction.
Enable
0 - 1
0
0
NO
Inhibit
1
9
REFRESH 
MODE(*1)
YES
Select of YES/NO of the manual pro-
cess control key with key operation
Key operation dis-
play
0 - 1
0
1
NO
Key operation NO 
display
1
MX-C250  SIMULATION  6 – 41
10
Process control 
conditions set-
ting
DAY
When the next warm-up if there is no 
color job after a color job after pass-
ing the specified days from execution 
of the previous color process control
Disable of the speci-
fied days judgment
0 - 999
0
1
1 - 999 days passing
999
11
HI-COV
Setting of the execution judgment of the process control in 
continuous printing of high print ratio images
0 - 2
0
12
LO-COV
Setting of the execution judgment of the process control in 
continuous printing of low print ratio images
0 - 1
0
13
REV1_SH
When the accumulated traveling distance of K or M OPC 
drum unit reaches the specified level after turning ON the 
power.
0 - 1
1
14
REV2_BK_SH
When the accumulated traveling distance of K OPC drum 
unit reaches the specified level from execution of the previ-
ous density correction.
0 - 1
1
15
REV2_CL_SH
When the accumulated traveling distance of M OPC drum 
unit reaches the specified level from execution of the previ-
ous density correction.
0 - 1
1
16
AVERAGE-PAGE
Setting of the number of pages of item HI-COV set value 2
1 - 10
3
17
LIMIT PAGE
Setting of the number of connected jobs of the process con-
trol and of the limit number of the process control
1 - 10
10
18
PIX_RATIO_BK
Variable magnification ratio setting (%) of the BK toner count 
specified value 
The set value of 100 corresponds to K print of A4 at the print 
ratio of 5%.
1 - 999
10
19
PIX_RATIO_CL
Variable magnification ratio setting (%) of the color (CMY) 
toner count specified value
The set value of 100 corresponds to K print of A4 at the print 
ratio of 5%.
1 - 999
10
20
INTERVAL TIME
Setting of the leaving time when turning ON the power 
(including the sleep recovery time) (h: hour)
1 - 255
3
21
HUM HOUR
Interval setting of the temperature and humidity monitoring 
time of "HUM" (unit: 10 minutes)
1 - 24
2
22
HUM_DIF
The specified value of the area difference in humidity 
between the level at execution of the previous control and the 
current humidity (Applied to item HUM)
1 - 9
2
23
BK_RATIO
Magnification ratio setting (%) of the specified value of the 
BK OPC drum traveling distance of "REV2_BK"
1-999 
(Entry of 20 corresponds 
to 100,000mm.)
15
24
M_RATIO
Magnification ratio setting (%) of the M OPC drum traveling 
distance of "REV2_CL"
1-999 
(Entry of 20 corresponds 
to 100,000mm.)
15
25
REV1_RATIO
Magnification ratio setting (%) of the specified value of the 
BK OPC drum traveling distance of "REV1"
1-999 20
26
REV1_RATIO_SH
Magnification ratio setting (%) of the M position OPC drum 
traveling distance of  "REV1_SH”
1-255
20
27
BK_RATIO_SH
Magnification ratio setting (%) of the specified value of the 
BK OPC drum traveling distance of "REV2_BK_SH"
1-999 15
28
M_RATIO_SH
Magnification ratio setting (%) of the M position OPC drum 
traveling distance of  "REV2_CL_SH”
1-999 15
29
COLOR BORDER
Magnification ratio setting (%) of the 
M position OPC drum traveling dis-
tance when executing the BK process 
control
BK process control 
is executed without 
judgment of ratio of 
the M OPC drum 
traveling distance. 
(Addition)
0 - 999
20
1 - 999(%)
30
BK ONLY
Disable/Enable setting and setting of 
the number of repetition of the BK 
process control when monochrome 
print is continued.
Enable 5 time
0 - 6
0
4
Disable 1-5 times
1 - 5
Inhibit
6
31
HT_DIF
Bias change difference value used for judgment of HT pro-
cess control
1 - 255
40
32
Registration 
adjustment set-
ting
RG_ON_SYNC
CL
Select of synchronous/asynchronous of the power ON pro-
cess control
0 - 2
0
0
ALL
1
CL/BK
2
33
RG_TEMP_TIMER
Execution timing setting after turning ON the power
0 - 240 (MINUTE)
0
34
RG_PERM_TIMER
Span setting from execution Disable to Enable
0 - 15 (HOUR)
0
35
RG_HOUR_TIMER
Span setting of timer execution
0-15 (Above)+(MINUTE)
6
36
RG_BW_SYNC
Setting of Enable/Disable of the registration adjustment after 
a monochrome job
0-1
1
Mode
Item/Display
Content
Setting range
Default 
value
MX-C250  SIMULATION  6 – 42
44-29
Purpose
:
Setting
Function (Purpose)
Used to set the operating conditions of the
process control during a job.
Section
Process
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
NOTE: Set the items to the default values unless a change is spe-
cially required.
44-31
Purpose
:
Adjustment/Setup
Function (Purpose)
Used to adjust the OPC drum phase. (Man-
ual adjustment)
Section
Process
Operation/Procedure
NOTE: For the OPC drum phase adjustment, do not use this simu-
lation, but use SIM50-22 (auto adjustment).
1) Select item A with Arrow key.
2) Enter the value corresponding to the adjustment pattern with 10
keys.
3) Press [OK]/[START] key. (The adjustment pattern is printed out.)
4) Select an adjustment pattern whose deflection is within two
scale lines on the adjustment pattern of C,M, Y colors.
5) Select item B with Arrow keys.
6) Enter the adjustment pattern sheet number selected in proce-
dure 4).
7) Press [OK]/[START] key.
8) The adjusted adjustment pattern is printed.
44-37
Purpose
:
Adjustment/Setup
Function (Purpose)
Used to set the development bias correc-
tion level in the continuous printing opera-
tion.
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
NOTE: When the print density is varied in the continuous printing
operation, this simulation is used.
44-43
Purpose
:
Data display
Function (Purpose)
Used to display the identification informa-
tion of the developing unit.
Section
Developing system
Operation/Procedure
The identification number and the identification signal level of the
developing unit are displayed.
Item/Display
Content
Setting range
Default 
value
1
COPY
During copy 
job
0 - 2
0
No execu-
tion
2
2
PRINTER
During print job
1
HV only
2
3
FAX
During FAX 
print job
2
HV  ->  HT
2
4
SELF 
PRINT
During self 
print
2
2
Item/Display
Content
Setting 
range
Default 
value
1
PRINT MODE
Print mode
1 : Deflection check pattern print for every  45 degrees (8-sheet print) 
1 - 3
3
(SET
VALUE)
2 : Deflection check pattern print for every 90 degrees (4-sheet print) 
3 : Deflection check pattern print at the set value (1-sheet print)
2
COLOR
Phase adjustment 
value BK -> CL
Angle step 0 degree (1)    45 degrees (2)   90 degrees (3)   135 degrees (4) 
180 degrees (5)   225 degrees (6)   270 degrees (7)   315 degrees (8)
1 - 8
1
3
PAPER
Tray selection
1 : Manual paper feed
1 -3
2
2 : 1 CS
3 : 2CS
Item/Display
Contents
Range
Default 
value
1
MUL_MC_ADJ
MC bias correction in the 
continuous printing is 
enabled / disabled. 
0-1
0
Item/Display
Content
Display 
range
1
DVCH KIND K
K color development unit identifica-
tion number
1 - 5
2
DVCH KIND C
C color development unit identifica-
tion number
1 - 5
3
DVCH KIND M
M color development unit identifica-
tion number
1 - 5
4
DVCH KIND Y
Y color development unit identifica-
tion number
1 - 5
5
DVCH_AD_K
K color developing unit identification 
number AD value
0 - 255
6
DVCH_AD_C
C color developing unit identification 
number AD value
0 - 255
7
DVCH_AD_M
M color developing unit identifica-
tion number AD value
0 - 255
8
DVCH_AD_Y
Y color developing unit identification 
number AD value
0 - 255
Page of 127