MX-C250  SIMULATION  6 – 31
44
44-1
Purpose
:
Setting
Function (Purpose)
Used to set each correction operation func-
tion in the image forming (process) section.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
NOTE: Set the items to the default values unless a change is spe-
cially required.
44-2
Purpose
:
Adjustment/Setup
Function (Purpose)
To execute the light quantity adjustment for
process control sensor and registrations
sensors (2pcs are done at same time), and
reading the surface of belt.
Section
Process
Operation/Procedure
When [OK]/[START] key is pressed, the adjustment is executed
automatically.
After completion of the adjustment, the adjustment result is dis-
played.
If the adjustment is not executed normally, "ERROR" is displayed.
Item/Display
Content
Setting 
range
Default 
value
1
HV
Normal operation high 
density process control 
Enable/Disable setting
Normal 
(Disable : 
1 : NO)
Reverse
(Enable : 
0 : YES)
0
2
HT
Normal operation half tone 
process control Enable/
Disable setting
0
3
TC
Transfer output correction 
Enable/Disable setting
0
4
MD  VG
Membrane decrease grid 
voltage correction Enable/
Disable setting
0
5
MD  LD
Membrane laser power 
voltage correction  Enable/
Disable setting
0
6
MD  EV
Membrane decrease envi-
ronment grid voltage cor-
rection Enable/Disable 
setting
0
7
MD DL
Membrane decrease dis-
charge light quantity cor-
rection 
Enable/Disable setting
0
8
MD DL EV
Membrane decrease envi-
ronment discharge light 
quantity correction 
Enable/Disable setting
1
9
MD  LD  EV
Membrane decrease envi-
ronment discharge light 
quantity correction Enable 
/ Disable setting
0
10
LD PROCON
Membrane laser power 
voltage correction by pro-
cess control Enable / Dis-
able setting
0
11
TN PIX SUP
Toner supply control by 
yield count Enable / Dis-
able setting 
0
12
TN FB
FEEDBACK toner density 
correction enable / disen-
able setting
0
13
TN INT
Interval toner supply con-
trol enable / disenable set-
ting
0
14
TN RECV
Developer recovery enable 
/ disenable setting
0
15
TN ADJ
Sensor output adjustment  
enable / disenable setting
0
16
TN EMP
Control the detection of 
toner drop amount enable/
disenable setting
0
17
TN EMP INT
Control the detection of 
toner drop amount when 
job intermission enable / 
disenable setting
0
18
TN EMP 
NEW
Control the detection of 
toner drop amount when 
installed new cartridge 
enable / disenable setting
0
19
TN PIX TBL
Execution the calculation 
of yield count correction 
table enable / disenable 
setting
Normal 
(Disable : 
1 : NO)
Reverse 
(Enable : 
0 : YES)
0
20
AR AUTO
Auto registration adjust-
ment Enable / Disable set-
ting
0
21
AR ERROR
Auto registration adjust-
ment execution error 
check Enable / Disable 
setting
0
22
DM PHASE
Drum phase fitting Enable/
Disable setting
0
23
PRT_HT
Half tone process control 
printer correction feed-
back Enable/Disable set-
ting
0
Item/Display
Content
1
P_F_CL_ka
F side color sensor correction factor
2
P_F LED ADJ
F sensor light emitting quantity adjustment 
value
3
P_R LED ADJ
R sensor light emitting quantity adjustment 
value
4
P_F_CL_DARK
Dark voltage of color (F side)
5
P_F DARK
Dark voltage of sensor (F side)
6
P_R DARK
Dark voltage of sensor (R side)
7
P_F GRND
Belt substrate when the item D adjustment 
is completed.
8
P_F BELT MAX
Belt substrate input max. value
9
P_F BELT MIN
Belt substrate input min. value
10
P_R GRND
Belt substrate when the item F adjustment 
is completed.
11
P_R BELT MAX
Belt substrate input max. value
12
P_R BELT MIN
Belt substrate input min. value
13
REG_F BELT MAX
Belt substrate input max. value (F side)
14
REG_F BELT MIN
Belt substrate input min. value (F side)
15
REG_R BELT MAX
Belt substrate input max. value (R side)
16
REG_R BELT MIN
Belt substrate input min. value (R side)
17
REG_F PATCH(K)
Patch light receiving potential F(K)
18
REG_F PATCH(C)
Patch light receiving potential F(C)
19
REG_F PATCH(M)
Patch light receiving potential F(M)
20
REG_F PATCH(Y)
Patch light receiving potential F(Y)
21
REG_R PATCH(K)
Patch light receiving potential R(K)
22
REG_R PATCH(C)
Patch light receiving potential R(C)
23
REG_R PATCH(M)
Patch light receiving potential R(M)
24
REG_R PATCH(Y)
Patch light receiving potential R(Y)
Error name
Error content
CL_SEN_ADJ_ERR
Color sensor adjustment abnormality
BK_SEN_ADJ_ERR
Black sensor adjustment abnormality
P_F_CL_ka
F Color sensor adjustment abnormality
P_F_GRND
F sensor basis material reading abnor-
mality
P_R_GRND
F sensor basis material reading abnor-
mality
REG_F_LED_ADJ
Registration sensor F adjustment abnor-
mality
Item/Display
Content
Setting 
range
Default 
value
MX-C250  SIMULATION  6 – 32
44-4
Purpose
:
Setting
Function (Purpose)
Used to set the conditions of the high den-
sity process control operation.
Section
Process
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
NOTE:
Set the items to the default values unless a change is spe-
cially required.
<*1 Reference value tables>
44-6
Purpose
:
Adjustment
Function (Purpose)
Used to execute the high density process
control forcibly.
Section
Process
Operation/Procedure
When [OK]/[START] key is pressed, the adjustment is exe-
cuted automatically.
After completion of the adjustment, the adjustment result is
displayed. (Refer to the table below.)
If the adjustment is not executed normally, "ERROR" is dis-
played.
REG_R_LED_ADJ
Registration sensor R adjustment abnor-
mality
REG_F_GRND
F registration basis material reading 
abnormality
REG_R_GRND
R registration basis material reading 
abnormality
Item/Display
Content
Setting 
range
Default 
value
1
PCS TARGET
Sensor target set value
1 - 255
204
2
PCS  ADJ  LIM
Sensor adjustment target limit 
value
1 - 255
8
3
BELT  G  DIF
Effective difference between the 
belt circuit substrate upper and 
lower limit values
1 - 255
1
4
B_BK STD DIF
Bias (for black) Target calcula-
tion difference
0 - 255
0
5
B PAT INT
Patch bias output interval
1 - 255
60
6
Y  TAR  ID
Patch density standard value 
(yellow)
1 - 255
*1
7
M TAR ID
Patch density standard value 
(magenta)
1 - 255
*1
8
C TAR ID
Patch density standard value 
(cyan)
1 - 255
*1
9
K  TAR  ID
Patch density standard value 
(black)
1 - 255
*1
10
HV BK_GR LIM
Patch position substrate light 
receiving effective range value
1 - 255
60
11
LED ADJ 
ROUGH
LED radiation quantity adjust-
ment rough 1step
1 - 255
5
12
LED ADJ 
ROUGH 
UPPER
LED radiation quantity adjust-
ment rough 1step execution  
threshold level  upper
1 - 255
240
13
LED ADJ 
ROUGH 
LOWER
LED radiation quantity adjust-
ment rough 1step execution  
threshold level  lower
1 - 255
140
14
K_PAT TARGET 
UPPER 1
Simplified process control solid-
patch transition judgment to high 
density process control upper 
limitation 1 (K-patch) 
1 - 255
10
15
K_PAT TARGET 
LOWER 1
Simplified process control solid-
patch transition judgment to high 
density process control lower 
limitation 1 (K-patch)
1 - 255
10
16
K_PAT TARGET 
UPPER 2
Simplified process control solid-
patch transition judgment to high 
density process control upper 
limitation 2 (K-patch) 
1 - 255
15
17
K_PAT TARGET 
LOWER 2
Simplified process control solid-
patch transition judgment to high 
density process control lower 
limitation 2 (K-patch)
1 - 255
15
18
K_HT TARGET 
UPPER 1
Simplified process control half-
tone-patch transition judgment 
to high density process control 
upper limitation 1 (K-patch) 
1 - 255
10
19
K_HT TARGET 
LOWER 1
Simplified process control half-
tone-patch transition judgment 
to high density process control 
lower limitation 1 (K-patch)
1 - 255
10
Error name
Error content
20
K_HT TARGET 
UPPER 2
Simplified process control half-
tone-patch transition judgment 
to high density process control 
upper limitation 2 (K-patch) 
1 - 255
15
21
K_HT TARGET 
LOWER 2
Simplified process control half-
tone-patch transition judgment 
to high density process control 
lower limitation 2 (K-patch)
1 - 255
15
22
CL_PAT TAR-
GET UPPER 1
Simplified process control solid-
patch transition judgment to high 
density process control upper 
limitation 1 (CL-patch) 
1 - 255
10
23
CL_PAT TAR-
GET LOWER 1
Simplified process control solid-
patch transition judgment to high 
density process control lower 
limitation 1 (CL-patch)
1 - 255
10
24
CL_PAT TAR-
GET UPPER 2
Simplified process control solid-
patch transition judgment to high 
density process control upper 
limitation 2 (CL-patch) 
1 - 255
15
25
CL_PAT TAR-
GET LOWER 2
Simplified process control solid-
patch transition judgment to high 
density process control lower 
limitation 2 (CL-patch)
1 - 255
15
26
CL_HT TAR-
GET UPPER 1
Simplified process control half-
tone-patch transition judgment 
to high density process control 
upper limitation 1 (CL-patch) 
1 - 255
10
27
CL_HT TAR-
GET LOWER 1
Simplified process control half-
tone-patch transition judgment 
to high density process control 
lower limitation 1 (CL-patch)
1 - 255
10
28
CL_HT TAR-
GET UPPER 2
Simplified process control half-
tone-patch transition judgment 
to high density process control 
upper limitation 2 (CL-patch) 
1 - 255
15
29
CL_HT TAR-
GET LOWER 2
Simplified process control half-
tone-patch transition judgment 
to high density process control 
lower limitation 2 (CL-patch)
1 - 255
15
30
SP_PAT COEF 
UPP DIF
Simplified process control den-
sity coefficient upper threshold 
level
1 - 255
10
31
SP_PAT COEF 
LOW DIF
Simplified process control den-
sity coefficient lower threshold 
level
1 - 255
10
No.
Item/Display
Default value for each Group
Group A
Group B
Group C
6
Y TAR ID
48
48
48
7 M 
TAR 
ID
50
50
50
8
C TAR ID
50
50
50
9
K TAR ID
48
50
48
Group
Destination
Group A
Japan
-
-
-
-
-
Group B
U.S.A.
Canada
Inch
-
-
-
Group C
Europe
U.K.
AUS
AB_A
China
AB_B
Result display
Content description
COMPLETE
Normal complete
Item/Display
Content
Setting 
range
Default
value
4
‘14/Apr
4
4
MX-C250  SIMULATION  6 – 33
44-9
Purpose
:
Operation data display
Function (Purpose)
: Used to display the results data of the high
density process control operation.
Section
:
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
ERROR
Abnormal end
INTERRUPTION
Forcible interruption
Details of error display
Content description
CL_SEN_ADJ_ERR
Color sensor adjustment abnormality
BK_SEN_ADJ_ERR
Black sensor adjustment abnormality
K_HV_ERR
K high density process control abnormality
C_HV_ERR
C high density process control abnormality
M_HV_ERR
M high density process control abnormality
Y_HV _ERR
Y high density process control abnormality
TIMEOUT_ERR
Time out
MODE
PAGE
ITEM
CONTETNT
DIS-
PLAY 
RANGE
DEFAU
LT
VALUE
PROCON
DATA
1/12
P DV K
High density pro-
cess control DV 
data
0 - 600
450
P DV C
 (KCMY)
P DV M
P DV Y
2/12
P GB K
High density pro-
cess control GB 
data
150 - 850
610
P GB C
 (KCMY)
P GB M
P GB Y
3/12
P DV K 
BASE
High density pro-
cess control DV 
data
0 - 600
450
P DV C 
BASE
(KCMY) Target 
P DV M 
BASE
P DV Y 
BASE
4/12
P GB K 
BASE
High density pro-
cess control GB 
data
150 - 850
630
P GB C 
BASE
(KCMY) Target
P GB M 
BASE
P GB Y 
BASE
5/12
N(M)
DV K
High density pro-
cess control nor-
mal (medium speed 
) DV data
0 - 600
450
N(M)
DV C
(KCMY)
N(M)
DV M
N(M)
DV Y 
Result display
Content description
PROCON
DATA
6/12
N(M) 
GB K
High density pro-
cess control nor-
mal (medium speed 
) GB data
150 - 850
630
N(M) 
GB C
(KCMY)
N(M) 
GB M
N(M) 
GB Y
7/12
N(M) 
DV K 
BASE
High density pro-
cess control nor-
mal (medium speed 
) DV data
0 - 600
450
N(M) 
DV C 
BASE
(KCMY) Target
N(M) 
DV M 
BASE
N(M) 
DV Y 
BASE
8/12
N(M) 
GB K 
BASE
High density pro-
cess control nor-
mal (medium speed 
) GB data
150 - 850
630
N(M) 
GB C 
BASE
(KCMY) Target
N(M) 
GB M 
BASE
N(M) 
GB Y 
BASE
9/12
N(L) DV 
K
High density pro-
cess control nor-
mal(low speed ) DV 
data
0 - 600
450
N(L) DV 
C
(KCMY)
430
N(L) DV 
M
N(L) DV 
Y
10/12
N(L) GB 
K
High density pro-
cess control nor-
mal(low speed ) DV 
data
150 - 850
615
N(L) GB 
C
(KCMY) 
595
N(L) GB 
M
N(L) GB 
Y
11/12
N(L) DV 
K BASE
High density pro-
cess control nor-
mal(low speed ) DV 
data
0 - 600
450
N(L) DV 
C BASE
(KCMY) Target
430
N(L) DV 
M BASE
N(L) DV 
Y BASE
12/12
N(L) GB 
K BASE
High density pro-
cess control nor-
mal(low speed ) GB 
data
150- 850
615
N(L) GB 
C BASE
(KCMY) Target
595
N(L) GB 
M BASE
N(L) GB 
Y BASE
MODE
PAGE
ITEM
CONTETNT
DIS-
PLAY 
RANGE
DEFAU
LT
VALUE
MX-C250  SIMULATION  6 – 34
OTHER
1/21
TN HUD 
AREA
Toner control dis-
play humidity area
1 - 16
8
TN HUD 
DATA
Toner control dis-
play humidity AD 
value
0 - 1023
0
TC TMP 
AREA
Transfer display 
temperature area
1 - 9
4
TC TMP 
DATA
Transfer display 
temperature AD 
value
0 - 1023
0
2/21
TC HUD 
AREA
Transfer display 
humidity area
1 - 9
4
TC HUD 
DATA
Transfer display 
humidity AD value
0 - 1023
0
MD
HUD 
AREA
Membrane 
decrease display 
humidity area
1 - 9
4
MD
HUD 
DATA
Membrane 
decrease display 
humidity AD
0 - 1023
0
value
3/21
MD K 
DRUM 
CNT
Membrane 
decrease drum 
traveling
0 - 20
0
MD C 
DRUM 
CNT
distance area 
(KCMY)
MD M 
DRUM 
CNT
MD Y 
DRUM 
CNT
4/21
MD K 
REV
LIFE M
LIFE grid voltage 
correction display 
(KCMY)
0 - 255
0
MD K 
REV
LIFE L
Medium speed / 
Low speed
MD C 
REV
LIFE M
MD C 
REV
LIFE L
5/21
MD M 
REV
LIFE M
MD M 
REV
LIFE L
MD Y 
REV
LIFE M
MD Y 
REV
LIFE L
6/21
MD K 
REV EV 
M
Environmental grid 
voltage correction 
display (KCMY) 
Medium speed / 
Low speed
-255 - 
255
-1
MD K 
REV EV 
L
0
MD C 
REV EV 
M
-1
MD C 
REV EV 
L
0
MODE
PAGE
ITEM
CONTETNT
DIS-
PLAY 
RANGE
DEFAU
LT
VALUE
OTHER
7/21
MD M 
REV EV 
M
Environmental grid 
voltage correction 
display (KCMY) 
Medium speed / 
Low speed
-255 - 
255
-1
MD M 
REV EV 
L
0
MD Y 
REV EV 
M
-1
MD Y 
REV EV 
L
0
8/21
MD K 
REV 
ALL M
Grid voltage correc-
tion ALL display 
(KCMY) medium 
speed / low speed
-255 - 
255
-1
MD K 
REV 
ALL L
0
MD C 
REV 
ALL M
-1
MD C 
REV 
ALL L
0
9/21
MD M 
REV 
ALL M
-1
MD M 
REV 
ALL L
0
MD Y 
REV 
ALL M
-1
MD Y 
REV 
ALL L
0
10/21
MD K 
REV LD 
M
Drum membrane 
decrease laser 
power voltage cor-
rection (KCMY) 
medium speed / 
low speed
0 - 255
100
MD K 
REV LD 
L
MD C 
REV LD 
M
MD C 
REV LD 
L
11/21
MD M 
REV LD 
M
MD M 
REV LD 
L
MD Y 
REV LD 
M
MD Y 
REV LD 
L
12/21
MD K 
REV LD 
EV M
Environmental 
changes and Drum 
membrane 
decrease laser 
power voltage cor-
rection (KCMY) 
medium speed / 
low speed
-255 - 
255
100
MD K 
REV LD 
EV L
MD C 
REV LD 
EV M
MD C 
REV LD 
EV L
MODE
PAGE
ITEM
CONTETNT
DIS-
PLAY 
RANGE
DEFAU
LT
VALUE
Page of 127