DOWNLOAD Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) Service Manual ↓ Size: 29.56 MB | Pages: 127 in PDF or view online for FREE

Model
MX-C250 MX-C250E MX-C250F MX-C250FE MX-C250FR MX-C300F MX-C300W MX-C300WE MX-C300A MX-C300WR (serv.man6)
Pages
127
Size
29.56 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual (Revised May 2016).
File
mx-c250-mx-c250e-mx-c250f-mx-c250fe-mx-c250fr-mx-c.pdf
Date

Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) Service Manual ▷ View online

MX-C250  SIMULATION  6 – 27
43-21
Purpose
:
Adjustment/Setup
Function (Purpose)
Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-1) in each paper mode.
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
Correction value: -49 - +49, 1 Count = 1 degrees C Change
*1: 1 Count = 1sec Change
<Code descriptions>
Correction 
value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Set-
ting 
range
Group 
A
Group 
B
Group 
C
Acc. 
Desti-
nation 
set-
ting(O
/X)
1
HL_UM READY HH
(HH-Correction) Ready standby TH_UM set value
1 - 99
50
50
50
X
2
HL_UM PLAIN BW HH
(HH-Correction) Black-White plain paper TH_UM set value
1 - 99
50
50
50
X
3
HL_UM PLAIN CL HH
(HH-Correction) Color plain paper TH_UM set value
1 - 99
50
50
50
X
4
WARMUP FUMON TMP HH
(HH-Correction) Fusing motor pre-rotation start TH_UM set value
1 - 99
50
50
50
O
5
WARMUP FUMOFF HH
(HH-Correction) Fusing motor pre-rotation end TH_LM set value
1 - 99
50
50
50
X
6
WARMUP END TIME HH
(HH-Correction) Warm-up complete time (warm-up time (sec))
1 - 99
50
50
50
X
7
HL_UM HEAVY HH
(HH-Correction) Heavy paper TH_UM set value
1 - 99
50
50
50
X
8
HL_UM OHP HH
(HH-Correction) OHP-TH_UM set value
1 - 99
50
50
50
X
9
HL_UM ENV HH
(HH-Correction) Envelope TH_UM set value
1 - 99
50
50
50
X
10
HL_UM GLOSS HH
(HH-Correction) Glossy paper TH_UM set value
1 - 99
50
50
50
X
11
HL_UM E-STAR HH
(HH-Correction) Preheating TH_UM set value
1 - 99
50
50
50
X
12
HL_UM PRE-JOB HH
(HH-Correction) Resetting from preheating TH_UM set value (Job Ready 
temperature)
1 - 99
50
50
50
X
13
HL_UM HEAVY2 CL HH
Correction value for heavy paper 2 TH_UM set value under LL environment
1 - 99
50
50
50
X
14
HL_UM WARMUP_120L 
HH
(HH-Correction) Warm-up TH_UM set value (when the fusing temperature 
is under 120 degrees C)
1 - 99
50
50
50
X
15
LO_WARMUP_TIME HH
(HH-Correction) Warm-up TH_UM applying time is under 120 degrees C 
(Timer from completion of warm-up)
1 - 99
50
50
50
X
16
HL_UM WARMUP_120H 
HH
(HH-Correction) Warm-up TH_UM applying time is 120 degrees C or above 
(Timer from completion of warm-up)
1 - 99
50
50
50
X
17
HI_WU_TIME HH
P applying time (timer from warm-up complete)
1 - 99
50
50
50
X
18
HI_WU_FM_ON_TMP HH
(HH-Correction) Fusing roller rotation start TH_E (when the fusing tempera-
ture in warm-up is alpha degrees C or above)
1 - 99
50
50
50
X
19
HI_WU_END_TIME HH
(HH-Correction) Warm-up complete time (sec) (when the fusing tempera-
ture in warm-up is alpha degrees C or above)
1 - 99
50
50
50
X
20
HI_WU_JOB_SET_TMP 
HH
(HH-Correction) Job Ready TH_UM temperature (when the fusing tempera-
ture in warm-up is alpha degrees C or above)
1 - 99
50
50
50
X
21
HI_WARMUP_BORDER 
HH
The threshold value alpha degree C or above in warm-up.
1 - 99
50
50
50
X
22
LO_WU_JOB_SET_TMP 
HH
The applying time in WUP TH_UM (CL) of 120 degrees C or above (Timer 
from completion of warm-up)
1 - 99
50
50
50
X
23
JOBEND_FUMON_TIME 
HH
(HH-Correction) Fusing roller rotation time (sec) after completion of a job
1 - 99
50
50
50
X
24
HI_WU_JOB_SET_TMP_H
H_BW
The applying time in WUP TH_UM (BW) of 120 degrees C or above (Timer 
from completion of warm-up)
1 - 99
50
50
50
X
TH_UM
Fusing upper thermister (center)
HL_UM
Heater lamp upper
TH_LM
Fusing lower thermister
HL_LM
Heater lamp lower
TH_E
Fusing thermister (external heat roller)
HL_E
Heater lamp (external heat roller)
Group
Destination
Group A
Japan
-
-
-
-
-
Group B
U.S.A.
Canada
Inch
-
-
-
Group C
Europe
U.K.
AUS
AB_A
China
AB_B
4
‘14/Apr
4
4
MX-C250  SIMULATION  6 – 28
43-22
Purpose
:
Adjustment/Setup
Function (Purpose)
Used to set the environment correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-4) in each paper mode.
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
Correction value: -49 - +49, 1 Count = 1 degrees C Change
*PLAIN BW DUP APP CNT LL, PLAIN CL DUP APP CNT LL:
1count = 1 sec
Other values: 1count = 1 degrees C
<Code descriptions>
Correction 
value
-49
-25
-5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Set-
ting 
range
Group 
A
Group 
B
Group 
C
Acc. Des-
tination
set-
ting(O/X)
1
HL_UM PLAIN BW DUP LL
(LL CORRECTION) Black-White plain paper duplex TH_UM 
set value
1 - 99
60
60
60
O
2
PLAIN BW DUP APP CNT LL
(LL CORRECTION) Black-White plain paper duplex fusing 
temperature application start image screen number
1 - 99
50
50
50
O
3
HL_UM PLAIN CL DUP LL
(LL CORRECTION) Color plain paper duplex TH_UM set 
value
1 - 99
60
60
60
O
4
PLAIN CL DUP APP CNT LL
(LL CORRECTION) Color plain paper duplex fusing tempera-
ture application start image screen number
1 - 99
50
50
50
O
5
HL_UM HEAVY BW DUP LL
(LL CORRECTION) Black-White heavy paper duplex TH_UM 
set value
1 - 99
55
55
55
X
6
HEAVY BW DUP APP CNT LL
(LL CORRECTION) Black-White heavy paper duplex fusing 
temperature application start image screen number
1 - 99
50
50
50
X
7
HL_UM HEAVY CL DUP LL
(LL CORRECTION) Color heavy paper duplex TH_UM set 
value
1 - 99
55
55
55
X
8
HEAVY CL DUP APP CNT LL
(LL CORRECTION) Color heavy paper duplex fusing temper-
ature application start image screen number
1 - 99
50
50
50
X
TH_UM
Fusing upper thermister (center)
HL_UM
Heater lamp upper
TH_LM
Fusing lower thermister
HL_LM
Heater lamp lower
TH_E
Fusing thermister (external heat roller)
HL_E
Heater lamp (external heat roller)
Group
Destination
Group A
Japan
-
-
-
-
-
Group B
U.S.A.
Canada
Inch
-
-
-
Group C
Europe
U.K.
AUS
AB_A
China
AB_B
4
‘14/Apr
4
4
MX-C250  SIMULATION  6 – 29
43-23
Purpose
:
Adjustment/Setup
Function (Purpose)
Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-04) in each paper mode.
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
Correction value: -49 - +49, 1 Count = 1 C Change
*PLAIN BW DUP APP CNT HH, PLAIN CL DUP APP CNT HH: 1count = 1 sec
Other values: 1count = 1 degrees C
<Code descriptions>
Correction 
value
-49
-25
-5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Set-
ting
range
Group 
A
Group 
B
Group 
C
Acc. Desti-
nation set-
ting(O/X)
1
HL_UM PLAIN BW DUP HH
(HH CORRECTION) Black-White plain paper duplex TH_UM 
set value
1 - 99
50
50
50
O
2
PLAIN BW DUP APP CNT HH
(HH CORRECTION) Black-White plain paper duplex fusing 
temperature application start image screen number
1 - 99
50
50
50
O
3
HL_UM PLAIN CL DUP HH
(HH CORRECTION) Color plain paper duplex TH_UM set value
1 - 99
50
50
50
O
4
PLAIN CL DUP APP CNT HH
(HH CORRECTION) Color plain paper duplex fusing tempera-
ture application start image screen number
1 - 99
50
50
50
O
5
HL_UM HEAVY BW DUP HH
(HH CORRECTION) Black-White heavy paper duplex TH_UM 
set value
1 - 99
50
50
50
X
6
HEAVY BW DUP APP CNT HH
(HH CORRECTION) Black-White heavy paper duplex fusing 
temperature application start image screen number
1 - 99
50
50
50
X
7
HL_UM HEAVY CL DUP HH
(HH CORRECTION) Color heavy paper duplex TH_UM set 
value
1 - 99
50
50
50
X
8
HEAVY CL DUP APP CNT HH
(HH CORRECTION) Color heavy paper duplex fusing tempera-
ture application start image screen number
1 - 99
50
50
50
X
TH_UM
Fusing upper thermister (center)
HL_UM
Heater lamp upper
TH_LM
Fusing lower thermister
HL_LM
Heater lamp lower
TH_E
Fusing thermister (external heat roller)
HL_E
Heater lamp (external heat roller)
Group
Destination
Group A
Japan
-
-
-
-
-
Group B
U.S.A.
Canada
Inch
-
-
-
Group C
Europe
U.K.
AUS
AB_A
China
AB_B
4
‘14/Apr
4
MX-C250  SIMULATION  6 – 30
43-24
Purpose
:
Adjustment/Setup
Function (Purpose)
Used to set the correction of the tempera-
ture adjustment value of SIM 43-1 and 43-
4.
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
Correction value: -49 - +49, 1 Count = 1 degrees C Change
*About the correction value
Each correction value for temperature: 1count = 1 degrees C
Each paper exit count: 1count = 1pcs paper
Each cool down time: 1count = 1sec
<Code descriptions>
Correction value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
Acc. Desti-
nation set-
ting(O/X)
1
NN_120_FUS_DUP_HL_UM
Correction amount for normal paper in duplex printing under 120 
degrees C in N/N-Warm Up
1 - 99
50
50
50
X
2
LL_120_FUS_DUP_HL_UM
Correction amount for normal paper in duplex printing under 120 
degrees C in L/L-Warm Up
1 - 99
50
50
50
X
3
HH_120_FUS_DUP_HL_UM
Correction amount for normal paper in duplex printing under 120 
degrees C in H/H-Warm Up
1 - 99
50
50
50
X
4
NN_120_FUS_DUP_CNT
Number of sheets of application of normal paper in duplex printing 
under 120 degrees C in N/N-Warm Up (Setting of the number of 
sheets at which application is started)
1 - 60
5
5
5
X
5
LL_120_FUS_DUP_CNT
Number of sheets of application of normal paper in duplex printing 
under 120 degrees C in L/L-Warm Up (Setting of the number of 
sheets at which application is started)
1 - 60
10
10
10
X
6
HH_120_FUS_DUP_CNT
Number of sheets of application of normal paper in duplex printing 
under 120 degrees C in H/H-Warm Up (Setting of the number of 
sheets at which application is started)
1 - 60
5
5
5
X
7
COOL_DOWN_HEAVY
Cool-down time heavy paper (Time (sec) required to return to the 
plain paper fusing temperature)
1 - 60
10
10
10
X
8
COOL_DOWN_OHP
Cool-down time OHP (Time (sec) required to return to the plain 
paper fusing temperature)
1 - 60
10
10
10
X
9
COOL_DOWN_ENVELOPE
Cool-down time envelope (Time (sec) required to return to the 
plain paper fusing temperature)
1 - 60
10
10
10
X
10
HL_UM THIN PAPER BW
Thin paper BW-TH_UM
70 - 230
145
145
145
O
11
HL_UM THIN PAPER CL
Thin paper COL-TH_UM
70 - 230
155
155
155
O
12
HL_UM THIN PAPER READY
Thin paper Ready-TH_UM
70 - 230
135
135
135
O
13
HL_UM REC PAPER BW
Recycled paper BW-TH_UM
70 - 230
160
170
170
O
14
HL_UM REC PAPER CL
Recycled paper COL-TH_UM
70 - 230
165
175
175
O
15
HL_UM REC PAPER READY
Recycled paper Ready-TH_UM
70 - 230
150
160
160
O
16
HPOWER_SET
Power voltage setting
1:100V 2:120V 3:230V
1 - 3
1
2
3
O
TH_UM
Fusing upper thermister (center)
HL_UM
Heater lamp upper
TH_LM
Fusing lower thermister
HL_LM
Heater lamp lower
TH_E
Fusing thermister (external heat roller)
HL_E
Heater lamp (external heat roller)
Group
Destination
Group A
Japan
-
-
-
-
-
Group B
U.S.A.
Canada
Inch
-
-
-
Group C
Europe
U.K.
AUS
AB_A
China
AB_B
4
‘14/Apr
4
4
Page of 127
Display

Click on the first or last page to see other MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) service manuals if exist.