Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) Service Manual ▷ View online
MX-C250 SIMULATION 6 – 23
27-7
Purpose
:
Setting
Function (Purpose)
Used to set of the enable, alert callout.
(FSS function)
(FSS function)
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
27-14
Purpose
:
Setting
Function (Purpose)
Used to set the FSS function connection
test mode.
test mode.
Section
Operation/Procedure
1) Enter the set value with 10 keys.
1) Press [OK]/[START] key.
The set value in step 1) is saved.
27-15
Purpose
:
Setting
Function (Purpose)
Used to display the FSS connection condi-
tion.
tion.
Section
Operation/Procedure
1) Enter the set value with 10 keys.
27-16
Purpose
:
Setting
Function (Purpose)
Used to FSS alert setting.
Section
Operation/Procedure
1) Enter the set value with 1 keys.
2) Press [OK]/[START] key.
The set value in step 1) is saved.
30
30-1
Purpose
:
Operation test/check
Function (Purpose)
Used to check the operations of the sen-
sors and the detectors in other than the
paper feed section and the control circuits.
sors and the detectors in other than the
paper feed section and the control circuits.
Section
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played.
The sensors and the detectors which are turned ON are high-
lighted.
The operating conditions of the sensors and detectors are dis-
played.
The sensors and the detectors which are turned ON are high-
lighted.
12
TONER DELIVERY
INTERVAL
INTERVAL
The threshold setting of toner comprehensive transport
1 - 15
3
Item/Display
Content
Setting
range
Default value
Remarks
Item/Display
Content
Range
Default
value
1
FUNCTION
0
FSS function enable
0 - 10
1(No)
1
FSS function disable
(*1) (Default)
(*1) (Default)
2
ALERT
0
Alert call enable (*2)
(Default)
(Default)
0(Yes)
1
Alert call disable
3
CONNEC-
TION
TION
0
By FAX
0(FAX)
1
Invalid
2
By HTTP
Item
Display
Contents
Range
Default
value
1
CONNECT
EST
ODE(1:ON
:OFF)
EST
ODE(1:ON
:OFF)
1
Enable FSS function
connection test mode.
connection test mode.
0 - 1
0 (OFF)
0
Disable FSS function
connection test mode.
connection test mode.
Item
Display
Contents
Range
Default
value
1
FSS
ONNEC-
TION
ONNEC-
TION
Display the FSS
connection.
connection.
0
Unused
0
1
Used
Item/Display
Contents
Setting
range
range
1
MAINTE-
NANCE ALERT
NANCE ALERT
0
Maintenance alert trans-
mission permission setting
mission permission setting
0 - 1
1
2
TONER
ORDER ALERT
ORDER ALERT
0
Toner order alert trans-
mission permission setting
mission permission setting
0 - 1
1
3
TONER CTRG
ALERT
ALERT
0
Toner cartridge alert
transmission permission
setting
transmission permission
setting
0 - 1
1
4
TROUBLE
ALERT
ALERT
0
Trouble alert transmis-
sion permission setting
sion permission setting
0 - 1
1
1
PPD2
Resist detection
2
POD1
Detects the paper exit from fusing.
3
TFD2
Paper exit tray full detection
4
DSW_R
Right door open/close detection
5
DSW_F
Front cover open/close detection
6
DHPD_K
OPC drum phase detection (K)
7
DHPD_CL
OPC drum phase detection (Color)
8
TNFD
Waste toner full detection
9
CPED1
1CS paper detection
14
MPED
Drum detection
16
C2LUD
2CS paper upper limit detection
17
C2PPD
2CS paper transport detection
18
DSW_C2
2CS transport cover open/close detection
19
CSS2
2CS tray detection
20
1TUD_K
Primary transfer belt separation detection (K)
21
1TUD_CL
Primary transfer belt separation detection (Color)
MX-C250 SIMULATION 6 – 24
43
43-1
Purpose
:
Setting
Function (Purpose)
Used to set the fusing reference tempera-
ture of each operation mode.
ture of each operation mode.
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
NOTE:
The set value is the reference value, and it may differ from
the actual fusing temperature depending on the operating
conditions.
the actual fusing temperature depending on the operating
conditions.
<Code descriptions>
Item/Display
Content
Setting
range
Group
A
Group
B
Group
C
1
HL_UM READY
Ready standby TH_UM set value
70 - 230
145
155
155
2
HL_UM PLAIN PAPER BW
Black-White plain paper TH_UM set value
70 - 230
155
165
165
3
HL_UM PLAIN PAPER CL
Color plain paper TH_UM set value
70 - 230
160
170
170
4
WARM UP END TIME
Warm-up complete time
1 - 255
13
13
13
5
HL_UM PRE-JOB
Resetting from preheating TH_UM set value
30 - 200
150
160
160
6
HL_UM WARMUP_120L
Warm-up TH_UM set value (when the fusing temperature is under 120 degrees C)
70 - 230
150
160
160
7
HL_UM WARMUP_120H
Warm-up TH_UM set value (when the fusing temperature is 120 degrees C or
above)
above)
70 - 230
150
160
160
8
HI_WU_FM_ON_TMP
Fusing roller rotation start TH_E (when the fusing temperature in warm-up is alpha
degrees C or above)
degrees C or above)
30 - 200
105
105
105
9
HI_WU_END_TIME
Warm-up complete time (sec) (when the fusing temperature in warm-up is alpha
degrees C or above)
degrees C or above)
0 - 255
13
13
13
10
HI_WU_JOB_SET_TMP
Job Ready TH_UM temperature (when the fusing temperature in warm-up is alpha
degrees C or above)
degrees C or above)
70 - 230
152
162
162
11
LO_WU_JOB_SET_TMP
Job Ready TH_UM temperature (CL) (When the fusing temperature in warming up
is under alpha degrees C.)
is under alpha degrees C.)
70 - 230
152
162
162
12
HL_UM_JOB_SET_TMP_BW
Job Ready TH_UM temperature (BW) (When the fusing temperature in warming up
is under alpha degrees C.)
is under alpha degrees C.)
70 - 230
152
162
162
1
HL_UM READY
Ready standby TH_UM set value
70 - 230
155
160
160
2
HL_UM PLAIN PAPER BW
Black-White plain paper TH_UM set value
70 - 230
165
170
170
3
HL_UM PLAIN PAPER CL
Color plain paper TH_UM set value
70 - 230
170
175
175
4
WARM UP END TIME
Warm-up complete time
1 - 255
13
13
13
5
HL_UM PRE-JOB
Resetting from preheating TH_UM set value
30 - 200
160
165
165
6
HL_UM WARMUP_120L
Warm-up TH_UM set value (when the fusing temperature is under 120 degrees C)
70 - 230
150
160
160
7
HL_UM WARMUP_120H
Warm-up TH_UM set value (when the fusing temperature is 120 degrees C or
above)
above)
70 - 230
160
165
165
8
HI_WU_FM_ON_TMP
Fusing roller rotation start TH_E (when the fusing temperature in warm-up is alpha
degrees C or above)
degrees C or above)
30 - 200
105
105
105
9
HI_WU_END_TIME
Warm-up complete time (sec) (when the fusing temperature in warm-up is alpha
degrees C or above)
degrees C or above)
0 - 255
13
13
13
10
HI_WU_JOB_SET_TMP
Job Ready TH_UM temperature (when the fusing temperature in warm-up is alpha
degrees C or above)
degrees C or above)
70 - 230
162
167
167
11
LO_WU_JOB_SET_TMP
Job Ready TH_UM temperature (CL) (when the fusing temperature in warm-up is
under alpha degrees C)
under alpha degrees C)
70 - 230
162
167
167
12
HL_UM_JOB_SET_TMP_BW
Job Ready TH_UM temperature (BW) (when the fusing temperature in warm-up is
under alpha degrees C)
under alpha degrees C)
70 - 230
162
167
167
1
WARMUP FUMON TMP
Fusing motor pre-rotation start TH_US set value (under alpha degrees C)
30 - 200
80
80
80
2
WARMUP FUMOFF
Preheating TH_E set value
0 - 255
30
30
30
3
HL_UM HEAVY PAPER
Resetting from preheating TH_UM set value (Job Ready temperature)
70 - 230
170
170
170
4
HL_UM OHP PAPER
Preheating TH_LM set value
70 - 230
150
150
150
5
HL_UM ENV PAPER
Warm-up TH_UM set value (when the fusing temperature is 120 degrees C or less)
70 - 230
180
180
180
6
HL_UM GLOSS PAPER
Warm-up TH_LM set value (when the fusing temperature is 120 degrees C or less)
70 - 230
160
160
160
7
HL_UM E-STAR
Warm-up TH_E set value (when the fusing temperature is 120 degrees C or less)
30 - 200
140
150
150
8
HL_UM HEAVY2 PAPER
Heavy paper 2 TH_UM set value
70 - 230
175
175
175
9
LO_WARMUP_TIME
The applying time in WUP TH_UM of 120 degrees C or less (Timer from completion
of warm-up)
of warm-up)
0 - 255
0
0
0
10
HI_WARMUP_TIME
The applying time in WUP TH_UM of 120 degrees C or above (Timer from comple-
tion of warm-up)
tion of warm-up)
70 - 230
0
0
0
11
HI_WARMUP_BORDER
The threshold value alpha degrees C or above in warm-up.
1 - 119
100
100
100
12
JOBEND_FUMON_TIME
Fusing motor after rotation time after completion of a job (Excluding heavy paper,
OPH, and envelopes)
OPH, and envelopes)
0 - 255
10
10
10
TH_UM
Fusing upper thermister (main)
HL_UM
Heater lamp upper
TH_LM
Fusing lower thermister (main)
HL_LM
Heater lamp lower
TH_E
Fusing thermister (external heat roller)
HL_E
Heater lamp (external heat roller)
Group
Destination
Group A
Japan
-
-
-
-
-
Group B
U.S.A.
Canada
Inch
-
-
-
Group C
Europe
U.K.
AUS
AB_A
China
AB_B
4
‘14/Apr
4
4
MX-C250 SIMULATION 6 – 25
43-4
Purpose
:
Setting
Function (Purpose)
Used to set the fusing Target temperature
of each operation mode (continuation of
SIM 43-01)
of each operation mode (continuation of
SIM 43-01)
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
<Code descriptions>
Item
Display
Content
Setting
range
Default value
Acc. Desti-
nation set-
ting(O/X)
Group
A
Group
B
Group
C
1
PLAIN
SwA
SwA
HL_UM PLAIN BW DUP
Black-White plain paper duplex TH_UM set value
70 - 230
155
165
165
O
2
PLAIN BW DUP APP CNT
Black-White plain paper duplex fusing temperature
application start image screen number
application start image screen number
0 - 60
0
0
0
O
3
HL_UM PLAIN CL DUP
Color plain paper duplex TH_UM set value
70 - 230
160
170
170
O
4
PLAIN CL DUP APP CNT
Color plain paper duplex fusing temperature appli-
cation start image screen number
cation start image screen number
0 - 60
0
0
0
O
1
PLAIN
SwB
SwB
HL_UM PLAIN BW DUP
Black-White plain paper duplex TH_UM set value
70 - 230
165
170
170
O
2
PLAIN BW DUP APP CNT
Black-White plain paper duplex fusing temperature
application start image screen number
application start image screen number
0 - 60
0
0
0
O
3
HL_UM PLAIN CL DUP
Color plain paper duplex TH_UM set value
70 - 230
170
175
175
O
4
PLAIN CL DUP APP CNT
Color plain paper duplex fusing temperature appli-
cation start image screen number
cation start image screen number
0 - 60
0
0
0
O
1
Other
HL_UM HEAVY BW DUP
Black-White heavy paper duplex TH_UM set value
70 - 230
170
170
170
X
2
HEAVY BW DUP APP CNT
Black-White heavy paper duplex fusing tempera-
ture application start image screen number
ture application start image screen number
0 - 60
0
0
0
X
3
HL_UM HEAVY CL DUP
Color heavy paper duplex TH_UM set value
70 - 230
170
170
170
X
4
HEAVY CL DUP APP CNT
Color heavy paper duplex fusing temperature
application start image screen number
application start image screen number
0 - 60
0
0
0
X
TH_UM
Fusing upper thermister (main)
HL_UM
Heater lamp upper
TH_LM
Fusing lower thermister (main)
HL_LM
Heater lamp lower
TH_E
Fusing thermister (external heat roller)
HL_E
Heater lamp (external heat roller)
Group
Destination
Group A
Japan
-
-
-
-
-
Group B
U.S.A.
Canada
Inch
-
-
-
Group C
Europe
U.K.
AUS
AB_A
China
AB_B
4
‘14/Apr
4
4
MX-C250 SIMULATION 6 – 26
43-20
Purpose
:
Adjustment/Setup
Function (Purpose)
Used to set the environmental correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-1) in each paper mode.
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-1) in each paper mode.
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
Correction value: -49 - +49, 1 Count = 1 degrees C Change
*WARMUP END TIME LL: 1count = 1sec / other correction value: 1 count = 1 degrees C
*The item D or F: When B5 paper, above value on item D or F is corrected “-5”
*The item G or I: When B5 paper, above value on item G or I is corrected “-5“
*The item D or F: When B5 paper, above value on item D or F is corrected “-5”
*The item G or I: When B5 paper, above value on item G or I is corrected “-5“
<Code descriptions>
Correction value
-49
-25
-5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Set-
ting
ting
range
Group
A
Group
B
Group
C
Acc.
Destina-
tion set-
tion set-
ting(O/X)
1
HL_UM READY LL
(LL-Correction) Ready standby TH_UM set value
1 - 99
65
65
65
X
2
HL_UM PLAIN BW LL
(LL-Correction) Black-White plain paper TH_UM set value
1 - 99
60
60
60
X
3
HL_UM PLAIN CL LL
(LL-Correction) Color plain paper TH_UM set value
1 - 99
60
60
60
X
4
WARMUP FUMON TMP
LL
LL
(LL-Correction) Fusing motor pre-rotation start TH_UM set value
1 - 99
40
40
40
O
5
WARMUP FUMOFF LL
(LL-Correction) Fusing motor pre-rotation end TH_LM set value
1 - 99
50
50
50
X
6
WARMUP END TIME LL
(LL-Correction) Warm-up complete time (warm-up time (sec))
1 - 99
50
50
50
X
7
HL_UM HEAVY LL
(LL-Correction) Heavy paper TH_UM set value
1 - 99
55
55
55
X
8
HL_UM OHP LL
(LL-Correction) OHP-TH_UM set value
1 - 99
55
55
55
X
9
HL_UM ENV LL
(LL-Correction) Envelope TH_UM set value
1 - 99
55
55
55
X
10
HL_UM GLOSS LL
(LL-Correction) Glossy paper TH_UM set value
1 - 99
55
55
55
X
11
HL_UM E-STAR LL
(LL-Correction) Preheating TH_UM set value
1 - 99
55
55
55
X
12
HL_UM PRE-JOB LL
(LL-Correction) Resetting from preheating TH_UM set value (Job Ready
temperature)
temperature)
1 - 99
55
55
55
X
13
HL_UM HEAVY2 CL LL
Correction value for heavy paper 2 TH_UM set value under LL environ-
ment
ment
1 - 99
55
55
55
X
14
HL_UM WARMUP_120L
LL
LL
(LL-Correction) Warm-up TH_UM set value (when the fusing tempera-
ture is under 120 degrees C)
ture is under 120 degrees C)
1 - 99
55
55
55
X
15
LO_WARMUP_TIME LL
(LL-Correction) Warm-up TH_UM applying time is under 120 degrees C
(Timer from completion of warm-up)
(Timer from completion of warm-up)
1 - 99
50
50
50
X
16
HL_UM WARMUP_120H
LL
LL
(LL-Correction) Warm-up TH_UM applying time is 120 degrees C or
above (Timer from completion of warm-up)
above (Timer from completion of warm-up)
1 - 99
55
55
55
X
17
HI_WU_TIME LL
P applying time (timer from warm-up complete)
1 - 99
50
50
50
X
18
HI_WU_FM_ON_TMP LL
(LL-Correction) Fusing roller rotation start TH_E (when the fusing tem-
perature in warm-up is alpha degrees C or above)
perature in warm-up is alpha degrees C or above)
1 - 99
40
40
40
X
19
HI_WU_END_TIME LL
(LL-Correction) Warm-up complete time (sec) (when the fusing tempera-
ture in warm-up is alpha degrees C or above)
ture in warm-up is alpha degrees C or above)
1 - 99
50
50
50
X
20
HI_WU_JOB_SET_TMP
LL
LL
(LL-Correction) Job Ready TH_UM temperature (when the fusing tem-
perature in warm-up is alpha degrees C or above)
perature in warm-up is alpha degrees C or above)
1 - 99
60
60
60
X
21
HI_WARMUP_BORDER
LL
LL
The threshold value alpha degrees C or above in warm-up.
1 - 99
50
50
50
X
22
LO_WU_JOB_SET_TMP
LL
LL
The applying time in WUP TH_UM (CL) of 120 degrees C or above
(Timer from completion of warm-up)
(Timer from completion of warm-up)
1 - 99
60
60
60
X
23
JOBEND_FUMON_TIME
LL
LL
(LL-Correction) Fusing roller rotation time (sec) after completion of a job
1 - 99
50
50
50
X
24
HI_WU_JOB_SET_TMP_L
L_BW
L_BW
The applying time in WUP TH_UM (BW) of 120 degrees C or above
(Timer from completion of warm-up)
(Timer from completion of warm-up)
1 - 99
60
60
60
X
TH_UM
Fusing upper thermister (center)
HL_UM
Heater lamp upper
TH_LM
Fusing lower thermister
HL_LM
Heater lamp lower
TH_E
Fusing thermister (external heat roller)
HL_E
Heater lamp (external heat roller)
Group
Destination
Group A
Japan
-
-
-
-
-
Group B
U.S.A.
Canada
Inch
-
-
-
Group C
Europe
U.K.
AUS
AB_A
China
AB_B
4
‘14/Apr
4
4
Click on the first or last page to see other MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) service manuals if exist.