Sharp MX-B201D (serv.man9) Service Manual ▷ View online
MX-B201/B201D SIMULATION, TROUBLE CODES 10 - 34
53
08
RSPF scan position
automatic adjustment
automatic adjustment
[Function]
Place a A4 paper (white chart) so that it covers the RSPF scan glass and the OC glass
together, and close the RSPF.
Place a A4 paper (white chart) so that it covers the RSPF scan glass and the OC glass
together, and close the RSPF.
When this simulation is executed, the current adjustment value is displayed as the initial display.
* Default is 1. Adjustment range is 1 – 99. Adjustment unit 1 = about 0.127mm
* If the values are kept as the default values, RSPF scan is not performed properly. The front
area of the proper scan position may be scanned.
In case of AUTO, press [START] key, and the mirror unit scans from the home position to the
SPF/RSPF scan position with the adjustment value displayed. The RSPF glass cover edge
position is calculated from the difference between the RSPF glass cover edge and the OC side
document glass CCD output level. If the adjustment is normal, the adjusted value is displayed. If
abnormal, the error LED lights up with the current set value displayed.
SPF/RSPF scan position with the adjustment value displayed. The RSPF glass cover edge
position is calculated from the difference between the RSPF glass cover edge and the OC side
document glass CCD output level. If the adjustment is normal, the adjusted value is displayed. If
abnormal, the error LED lights up with the current set value displayed.
During the error LED is lighted, when [START] key is pressed again, execution is performed
again.
again.
[Operation]
The operation is similar to simulation 46-01. (In MANUAL)
The operation is similar to simulation 46-01. (In MANUAL)
OK/ERR display in AUTO
61
03
Polygon motor check
(HSYNC output check)
(HSYNC output check)
[Function]
When [ENTER]/[START] key is pressed, HSYNC is performed and the polygon motor is rotated
for 30sec.
When [ENTER]/[START] key is pressed, HSYNC is performed and the polygon motor is rotated
for 30sec.
At that time the COPY mode lamp is lighted for 100msec every time when HSYNC is detected.
[Operation]
63
01
Shading check
[Function]
Used to display the detection level of white plate for shading.
Used to display the detection level of white plate for shading.
When [ENTER]/[START] key is pressed, the mirror base unit moves to the white plate for shad-
ing and the copy lamp is lighted.
ing and the copy lamp is lighted.
When the light quantity is stabilized, revision is made for every second, and the level of one
pixel at the center of CCD which is not corrected is detected and the value is displayed in deci-
mal values on the LCD/display. (3 digits)
pixel at the center of CCD which is not corrected is detected and the value is displayed in deci-
mal values on the LCD/display. (3 digits)
[Operation]
Main
code
code
Sub
code
Contents
Details of function/operation
Mode
Display item
LED
Default
RSPF scan position auto adjustment
AUTO
COPY mode lamp
1
RSPF scan position manual adjustment
MANU
PRINT mode lamp
1
<When OK>
<When ERR>
53-08 SPF AUTO
AUTO 100% ** OK
53-08 SPF AUTO
AUTO 100% ** ERR
1) Initial display
61-03 LSU CHK
EXECUTING...
1) Initial display
63-01 SHADING CHK
EXECUTING... 000
MX-B201/B201D SIMULATION, TROUBLE CODES 10 - 35
63
02
Black level automatic
correction
correction
[Function]
Used to acquire the black level target value used for the black level adjustment of white balance.
Used to acquire the black level target value used for the black level adjustment of white balance.
When this simulation is executed, the current correction value is displayed in 3 digits of 12bit
hexadecimal number.
hexadecimal number.
Place the gray gradation chart (UKOG-0162FCZZ) used as the correction document so that the
density 10 (black side) comes on the left side and that the chart is upside down at the center of
the plate left center.
density 10 (black side) comes on the left side and that the chart is upside down at the center of
the plate left center.
When [ENTER]/[START] key is pressed, the mirror base unit scans the chart and calculates the
correction value.
correction value.
After completion of correction, the corrected value is displayed on the LCD/display.
* Default: 0
* If the value is set to the default, operation is made with 0x60.
* When error is occur JAM lamp is ON.
[Operation]
12
Light quantity stabilization
wait time setting
wait time setting
[Function]
Used to set the wait time before entering the light quantity level stable evaluation process in the
light quantity stable process of white balance. (Note: The light quantity stable level in the previ-
ous light quantity stable state is used as the target. When the light quantity level reaches the
target during the wait time, the set time of this simulation is ignored and the operation enters the
stable evaluation process.)
Used to set the wait time before entering the light quantity level stable evaluation process in the
light quantity stable process of white balance. (Note: The light quantity stable level in the previ-
ous light quantity stable state is used as the target. When the light quantity level reaches the
target during the wait time, the set time of this simulation is ignored and the operation enters the
stable evaluation process.)
When this simulation is executed, the currently set value is displayed.
Enter the adjustment value with [Numeric] key and press [START] key. The entered value is
stored and the machine goes into the sub code entry standby mode.
Setting range: 0 – 99 (Complying with the light quantity stable wait time of 0 – 99sec.)
Enter the adjustment value with [Numeric] key and press [START] key. The entered value is
stored and the machine goes into the sub code entry standby mode.
Setting range: 0 – 99 (Complying with the light quantity stable wait time of 0 – 99sec.)
Default: 15 (15sec)
[Operation]
The operation is similar to simulation 9-04.
The operation is similar to simulation 9-04.
13
Light quantity stabilization
band setting
band setting
[Function]
When the difference between the maximum and the minimum values of the light quantity level
sampled for 3.2sec in the cycle of 100msec in the white balance light quantity stable process is
within the range set with this simulation, it is judged as the light quantity is stable. (Note: The
magnification ratio of the AFE gain setting is automatically reflected on the stable width.)
When the difference between the maximum and the minimum values of the light quantity level
sampled for 3.2sec in the cycle of 100msec in the white balance light quantity stable process is
within the range set with this simulation, it is judged as the light quantity is stable. (Note: The
magnification ratio of the AFE gain setting is automatically reflected on the stable width.)
When this simulation is executed, the currently set value is displayed.
Enter the adjustment value with [Numeric] key and press [START] key. The entered value is
stored and the machine goes into the sub code entry standby mode.
Enter the adjustment value with [Numeric] key and press [START] key. The entered value is
stored and the machine goes into the sub code entry standby mode.
Setting range: 1 – 99 (Light quantity stable width: Complying with 1 – 99 in 4095 gradations.)
Default: 16
[Operation]
The operation is similar to simulation 9-04.
The operation is similar to simulation 9-04.
Main
code
code
Sub
code
Contents
Details of function/operation
Chart back surface
10
1) Initial display
2) [ENTER]/[START] key:
Correction start
63-02 BLACK LEVEL
000
63-02 BLACK LEVEL
EXECUTING...
<During canceling - When [Clear]/[Clear All] key is
pressed->
pressed->
After canceling, the machine goes into the sub
code entry standby mode.
code entry standby mode.
3) After execution
3) In case of an error
THE JOB IS BEING
CANCELED.
63-02 BLACK LEVEL
*** OK
63-02 BLACK LEVEL
*** ERR
MX-B201/B201D SIMULATION, TROUBLE CODES 10 - 36
64
01
Self print
[Function]
The status of the optical section is ignored and printing of one page is made. Also when the
print command is received from the host, printing is made.
The status of the optical section is ignored and printing of one page is made. Also when the
print command is received from the host, printing is made.
When this simulation is executed, warm-up is performed and the ready lamp is lighted. (Since,
however, the scanner is disabled, initializing is not made.)
however, the scanner is disabled, initializing is not made.)
Enter the code number and press [ENTER/[START] key to start paper feed from the selected
cassette and print in the selected pattern.
cassette and print in the selected pattern.
* For 4 – 99, flip.
[Operation]
The operation is similar to simulation 26-02.
The operation is similar to simulation 26-02.
66
01
FAX soft SW setting
(When MX-FX12 is installed)
(When MX-FX12 is installed)
[Function]
Use to check the FAX soft SW setting.
Every time when the key is pressed, the bit on the first line is switched 0 and 1.
Use to check the FAX soft SW setting.
Every time when the key is pressed, the bit on the first line is switched 0 and 1.
[Operation]
02
FAX soft SW initializing
(excluding the adjustment
values)
(When MX-FX12 is installed)
(excluding the adjustment
values)
(When MX-FX12 is installed)
[Function]
Use to initializing FAX soft SW.
Use to initializing FAX soft SW.
[Operation]
Main
code
code
Sub
code
Contents
Details of function/operation
Code number
Pattern
Display item
0
1by2
1 BY 2
1
Grid pattern
CHECK
2
White paper
WHITE
3
Black background
BLACK
1
1) Initial display
* [Clear] key: FAX control is terminated.
2) Enter a 3-digit value of soft SW No. (To
enter the fourth digit, shift to the left.),
and the press [OK] key.
and the press [OK] key.
"xxxxxxxx" is the set content.
* Select 2: Returns to the soft SW No. entry
display.
3) Select 1
4) Change with 1-8 of [Numeric] key and
the press [OK] key.
"xxxxxxxx" is the set content.
* Select 2: Returns to the soft SW No. entry
display.
5) Select 1
After 2sec, returns to "1) Initial display".
ENTER FAX SOFT SW. #
(3 DIGITS) SW.___
No.### xxxxxxxx
CHANGE? 1:YES 2:NO
No.### xxxxxxxx
USE # KEY 12345678
No.### xxxxxxxx
STORED? 1:YES 2:NO
STORED
1) Initial display
After 2sec, FAX control is terminated.
INITIALIZED
:'11/Oct/17
1
MX-B201/B201D SIMULATION, TROUBLE CODES 10 - 37
66
03
FAX PWB memory check
(When MX-FX12 is installed)
(When MX-FX12 is installed)
[Function]
Use to check the FAX PWB memory.
Use to check the FAX PWB memory.
[Operation]
Main
code
code
Sub
code
Contents
Details of function/operation
1
1) Initial display
2) [
] or [
] key or 2sec.
Every time when [
] key is pressed, the second line is changed in the sequence of No. 1
→ 2 → 1.
When [
When [
] key is pressed, the sequence is reversed.
* [Clear] key: SIM menu
3) [OK] key
4) After completion of check
In case of 1: MODEM
• When the result is OK
• When the result is NG
In case of 2: FLASH
• When the result is OK
• When the result is NG
No File system/Access Error/File system
Error
Error
I/O error
SELECT CHECK MEMORY
PRESS
←, →
SELECT MEMORY (1-2)
1:MODEM
SELECT MEMORY (1-2)
2:FLASH
CHECKING MEMORY
MEMORY CHECK RESULT
MODEM OK
MEMORY CHECK RESULT
MODEM NG
MEMORY CHECK RESULT
FLASH OK
MEMORY CHECK RESULT
FLASH SYSTEM NG
MEMORY CHECK RESULT
FLASH HARDWARE NG
:'11/Oct/17