Sharp MX-B201D (serv.man9) Service Manual ▷ View online
MX-B201/B201D SIMULATION, TROUBLE CODES 10 - 14
26
07
Machine conditions check
[Function]
When this simulation is executed, the current machine setting is displayed.
When this simulation is executed, the current machine setting is displayed.
[Operation]
20
Rear edge void setup
[Function]
When this simulation is executed, the current set rear edge void is displayed. Enter the code
number corresponding to the desired rear edge void and press [ENTER]/[START] key to save
the setting.
When this simulation is executed, the current set rear edge void is displayed. Enter the code
number corresponding to the desired rear edge void and press [ENTER]/[START] key to save
the setting.
[Operation]
The operation is similar to simulation 26-02.
The operation is similar to simulation 26-02.
30
CE mark support control
ON/OFF
ON/OFF
[Function]
When this simulation is executed, the current set CE mark support control is displayed. Enter
the code number corresponding to the desired CE mark support control and press [ENTER]/
[START] key to save the setting.
When this simulation is executed, the current set CE mark support control is displayed. Enter
the code number corresponding to the desired CE mark support control and press [ENTER]/
[START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
The operation is similar to simulation 26-02.
37
Cancel of stop at developer
life over
life over
[Function]
When this simulation is executed, the current setting is displayed. When the code number is
entered and [START] key is pressed, the setting is changed.
When this simulation is executed, the current setting is displayed. When the code number is
entered and [START] key is pressed, the setting is changed.
39
Memory capacity check
[Function]
When the simulation is executed, the currently installed SDRAM of the main unit is displayed.
When the simulation is executed, the currently installed SDRAM of the main unit is displayed.
[Operation]
40
Polygon motor OFF time
setup (Time required for
turning OFF after completion
of printing)
setup (Time required for
turning OFF after completion
of printing)
[Function]
When this simulation is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [ENTER]/[START] key to save the setting.
When this simulation is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [ENTER]/[START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
The operation is similar to simulation 26-02.
Main
code
code
Sub
code
Contents
Details of function/operation
CPM
Copy quantity
Remark
20 CPM
20
1) The machine setting is displayed.
26-07 CPM
20 CPM
Code number
Setting
Display item
Remark
0
Rear edge void NO
OFF
1
Rear edge void YES
ON
Default
Code number
Setting
Display item
Remark
0
CE mark support control OFF
OFF
Default (100V series)
1
CE mark support control ON
ON
Code number
Setting
Remark
0
Stop at developer life over
1
Cancel of stop at developer life over
Default
Code number
Setting
Remark
32
32 MBYTE
64
64 MBYTE
1
1) Memory capacity display
26-39 MEM.CHK
32 MBYTE
Code number
Setting
Display item
Remark
0
0sec
0 SEC.
1
30sec
30 SEC.
Default
2
60sec
60 SEC.
3
90sec
90 SEC.
:'11/Oct/17
1
MX-B201/B201D SIMULATION, TROUBLE CODES 10 - 15
26
42
Transfer ON timing control
setup
setup
[Function]
[Operation]
Main
code
code
Sub
code
Contents
Details of function/operation
When this simulation is executed, the currently set code number is displayed.
Enter the code number and press the [START] key, and the setting will be changed. (For any
number different from the following ones, the default time is automatically set.)
number different from the following ones, the default time is automatically set.)
The adjustment can be made individually for each of the following modes.
<Paper lead edge adjustment table>
Note 1:
The default code ‘11’ for the transfer ON timing indicates a lapse of 236ms from PS release.
The default code ‘11’ for the transfer ON timing indicates a lapse of 236ms from PS release.
Note 2:
If the code “0” is selected, the setting is the same as the default setting ‘11’.
If the code “0” is selected, the setting is the same as the default setting ‘11’.
Note 3:
The transfer ON timing can be adjusted in increments/decrements of 2ms within the range of
236ms±20ms.
The transfer ON timing can be adjusted in increments/decrements of 2ms within the range of
236ms±20ms.
<Front/back surface of paper rear edge adjustment table>
* The default "50" of the transfer OFF timing indicates "210msec passed from PPD1OFF."
* The transfer OFF timing can be adjusted to 210msec ± 2ms.
Mode
Display item
Default
Setting range
Front surface paper lead edge
F-REAR
11
0 - 21
Front surface paper rear edge
F-END
50
1 - 99
Back surface paper lead edge
B-REAR
11
0 - 21
Back surface paper rear edge
B-END
50
1 - 99
Code
Setting
Remark
0
0 msec
1
–20 msec
. . .
. . .
10
–2 msec
11
0 msec
Default
12
2 msec
. . .
. . .
21
20 msec
Code
Setting
Remark
1
–98 msec
. . .
. . .
49
–2 msec
50
0 msec
Default
51
+2 msec
. . .
. . .
99
+98 msec
1) Initial display
<Front surface lead edge setting>
2) [
] [
] key: Mode selection
3) [Numeric] key: Value entry
4) [ENTER]/[START] key:
Settles the entered value. The display is
shifted to the sub code input standby
menu.
shifted to the sub code input standby
menu.
26-42 TC ON TIMING
F-REAR 11( 0-21 )
26-42 TC ON TIMING
F-END 50( 1-99 )
26-42 TC ON TIMING
F-END 51( 1-99 )
MX-B201/B201D SIMULATION, TROUBLE CODES 10 - 16
26
43
Side void setup
[Function]
When this simulation is executed, the currently set code of the side void quantity is displayed
(initial display), and the set data are saved. (Setting range: 0 – 10, Default: 4 (= One side
2.0mm))
When this simulation is executed, the currently set code of the side void quantity is displayed
(initial display), and the set data are saved. (Setting range: 0 – 10, Default: 4 (= One side
2.0mm))
* When the adjustment value is increased by 1, the side void is changed as follows:
Side void adjustment: The side void is increased by 0.5mm. (The side void of "Set value x
0.5mm" is made.)
0.5mm" is made.)
[Operation]
The operation is similar to simulation 09-04.
The operation is similar to simulation 09-04.
54
γ life correction setting
[Function]
Used to set the
Used to set the
γ life correction.
When this simulation is executed, the current set code number is displayed.
Enter the desired code number and press [ENTER]/[START] key to save the setting.
(Setting range: 0 – 1, default: 1)
(Setting range: 0 – 1, default: 1)
[Operation]
The operation is similar to simulation 26-02.
The operation is similar to simulation 26-02.
62
Energy-save mode copy
lamp setup
lamp setup
[Function]
Used to set half-ON /OFF of the copy lamp in the pre-heat mode.
Used to set half-ON /OFF of the copy lamp in the pre-heat mode.
When this simulation is executed, the current set code number is displayed. Enter the desired
code number and press [ENTER]/[START] key to save the setting.
code number and press [ENTER]/[START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
The operation is similar to simulation 26-02.
69
Use to set the operation
conditions for toner near end
conditions for toner near end
[Function]
This simulation is used to set the operating conditions for toner near end.
This simulation is used to set the operating conditions for toner near end.
For except Japan, China performs operation of set value "3" regardless of the setting value.
Main
code
code
Sub
code
Contents
Details of function/operation
Code
Setting
Remark
0
0 mm
1
0.5 mm
2
1.0 mm
3
1.5 mm
4
2.0 mm
Default
5
2.5 mm
6
3.0 mm
7
3.5 mm
8
4.0 mm
9
4.5 mm
10
5.0 mm
Code number
Setting
Display item
Remark
0
OFF
OFF
1
ON
ON
Default
Code number
Setting
Display item
Remark
0
Copy lamp OFF
OFF
1
Copy lamp half-ON
ON
Default
<Toner near end display/No display>
<Setting of operations at toner end>
Code number
Setting contents
0
Toner near end is displayed
1
Toner near end is not displayed
Code number
Setting contents
1
Operation setting 1
2
Operation setting 2
3
Operation setting 3
MX-B201/B201D SIMULATION, TROUBLE CODES 10 - 17
30
01
Paper sensor status display
[Function]
The paper sensor status is displayed on the LCD.
The paper sensor status is displayed on the LCD.
[Operation]
41
06
OC cover float detection
level adjustment
(Only when RSPF installed)
level adjustment
(Only when RSPF installed)
[Function]
When this simulation is executed, the current set value is displayed. When [ENTER]/[START]
key is pressed, the mirror base unit moves to the RSPF scan position to acquire the OC cover
float detection level.
When this simulation is executed, the current set value is displayed. When [ENTER]/[START]
key is pressed, the mirror base unit moves to the RSPF scan position to acquire the OC cover
float detection level.
When the mirror base unit returns to the home position, the acquired value is displayed.
If the adjustment is NG, the following message is displayed.
The LCD indicates "ERR."
Note that, this simulation must be executed with the OC cover closed.
∗ If the value is 0, float detection is not performed in normal jobs.
∗ If the value is 0, float detection is not performed in normal jobs.
[Operation]
07
OC cover float detection
margin setting
(Only when RSPF installed)
margin setting
(Only when RSPF installed)
[Function]
For the number of pixels between black markers on the SPF/RSFP scanning position saved in
"41-06: (OC cover float detection level adjustment)", if the number of pixels between the mark-
ers when processing float detection is less than the number of pixels set with this simulation, it
is judged as the float error.
For the number of pixels between black markers on the SPF/RSFP scanning position saved in
"41-06: (OC cover float detection level adjustment)", if the number of pixels between the mark-
ers when processing float detection is less than the number of pixels set with this simulation, it
is judged as the float error.
When the set value of this simulation is "0," no float error occurs.
When this simulation is executed, the current set value is displayed.
Enter the adjustment value with [Numeric] key and press [START] key. The setting is saved and
the display is shifted to the sub code input standby menu.
Setting range: 0 – 99 (Copes with margin 0 – 99 pixels.)
the display is shifted to the sub code input standby menu.
Setting range: 0 – 99 (Copes with margin 0 – 99 pixels.)
Default: 30 (30 pixels)
[Operation]
The operation is similar to simulation 9-04.
The operation is similar to simulation 9-04.
Main
code
code
Sub
code
Contents
Details of function/operation
Sensor
Display item
Paper exit sensor
POD
Paper width detection for Tray 1
PD1
Paper width detection for Tray 2
PD2
Paper entry sensor
PPD1
Duplex sensor
PPD2
New drum cartridge sensor
DRST
1) Initial display
2) When sensor ON
30-01 P-SENSOR
30-01 POD PD1 PD2
PPD1 PPD2 DRST
1) Initial display
2) [ENTER]/[START] key
41-06 OC FLOAT LEVEL
0
41-06 OC FLOAT LEVEL
EXECUTING...
<Canceling - when [Clear]/[Clear All] key is pressed->
After canceling, the machine goes into the sub code entry
standby mode.
standby mode.
3) When the level is acquired:
3) When the level is not acquired:
THE JOB IS BEING
CANCELED.
41-06 OC FLOAT LEVEL
**** OK
41-06 OC FLOAT LEVEL
**** ERR
Click on the first or last page to see other MX-B201D (serv.man9) service manuals if exist.