MX-B201/B201D  ADJUSTMENTS  9 - 6
B. DV bias check
Procedures
1) Set the digital multi meter range to DC500V.
2) Set the positive side of the test rod to the connector CN-10-1
(DV BIAS) and set the negative side to the frame ground
(power frame).
3) Execute SIM 8-1 to output the developing bias for 30sec, and
check that the output is –400 ± 8V.
4. Duplex adjustment
A. Adjusting the paper reverse position in 
memory for duplex copying
This step adjusts the front surface printing (odd-number pages of a
document set) in the S-D mode copying and the leading edge posi-
tion of an image on even-number pages in the D-S mode.
That is, it covers the adjustment of the second surface printing
mode (image loss at the front edge of an image) in which image
data is once stored in memory.
The image data is read, starting from its front end in the document
delivery direction (Reference direction of document setting in the
OC mode)and stored in memory.
This stored image data is printed starting at the printing start posi-
tion, in the order of last-stored data to the first-stored data.
In other words, the front edge image loss of the image can be
adjusted by changing the document read end position.
(Adjustment procedure)
1) Preparing test chart (Draw a scale at the rear end of one side of
a sheet of A4 white paper or letter paper)
2) Set the test chart so that the scale is positioned as shown
below, in the S-D mode and the D-S mode.
3) Execute simulation 50-18.
Select the RSPF memory reverse output position, and press
[START] key to make a copy.
Adjust the setting so that the front edge image loss is less than
4.0 mm in the RSPF mode.
An increase of 1 in setting represents an increase of 0.1 mm in
image loss.
B. Adjusting trailing edge void in duplex copy 
mode
This is the adjustment of the first surface printing mode (rear end
void) in duplex copying.
In a duplex copying operation, the paper is delivered starting from
the rear end of the first printing surface. It is therefore necessary to
make a void area at the rear end on the first printing surface to pre-
vent paper jam at the fusing part.
There are two adjustment modes:
1) Paper trailing edge void quantity 50-19 (TEXT)
This adjustment is made when the cassette paper size is rec-
ognized. The trailing edge void quantity can be adjusted by
changing the trailing edge image laser OFF timing.
Note: • A digital multi meter with internal resistance of 1G
Ω must
be use for correct check.
• The adjustment volume is locked, and no adjustment can
be made.
VRDV
5 10
Mode
Display item Default
OC memory reverse output position 
OC
50
RSPF memory reverse output position
RSPF
50
Scale (S-D mode)
Scale (D-S mode)
5 10
The front edge of the
scale on test chart
 Front edge of paper
Void area
less than 4 mm
2nd printing surface where scale is printed (lower side)
MX-B201/B201D  ADJUSTMENTS  9 - 7
2) Print start position (Duplex back surface) (RSPF) 50-19
(PHOTO)
The size (length) of a document read from the RSPF is
detected, the image at the trailing edge of the first printing sur-
face is cut to make a void area. (The adjustment of void quantity
at the time when the cassette paper size is not recognized.)
The paper void quantity should be first adjusted before the image
cut trailing edge void quantity (RSPF) is adjusted.
(Adjustment procedure)
(1)
Paper trailing edge void quantity
1) Preparing test chart (Draw a scale at the rear end of one side
of a sheet of A/4 white paper or letter paper)
2) Set the test chart on the document glass as shown below.
3) Using the user simulation [18], set the paper size of the first
cassette.
• Letter paper: 4
• A4 paper: 3
4) Execute SIM 50-19 to turn on the PRINT mode lamp and make
the printing mode in OC-D mode.
Make a copy of the test chart to check the void area of the scale
on the image.
Adjust the setting so that the void area is 4 - 5 mm. An increase in
1 of setting represents 0.1 mm in void area.
(2)
Print start position (Duplex back surface)
1) Set the test chart so that the scale is positioned as shown
below.
2) Execute SIM 50-19 to turn on the SCAN mode lamp and make
the printing mode in the S-D mode.
3) Remove and reinsert the cassette.
Note: Make sure to carry out this step before making a copy dur-
ing this adjustment.
4) Make a copy and check the void area of the scale on the
image.
Adjust the setting so that the void area is 2 - 4 mm. An
increase of 1 in setting represents an increase of 0.1 mm in
void area.
Void position to be checked
5. RSPF scan position automatic 
adjustment
Place a A4 paper (white chart) so that it covers the RSPF scan
glass and the OC glass together, and close the RSPF.
When simulation 53-08 is executed, the current adjustment value is
displayed as the initial display.
* Default is 1. Adjustment range is 1 – 99. Adjustment unit 1 =
about 0.127mm
* If the values are kept as the default values, RSPF scan is not per-
formed properly. The front area of the proper scan position may
be scanned.
In case of AUTO, press [START] key, and the mirror unit scans from
the home position to the RSPF scan position with the adjustment
value displayed. The SPF glass cover edge position is calculated
from the difference between the SPF glass cover edge and the OC
side document glass CCD output level. If the adjustment is normal,
the adjusted value is displayed. If abnormal, the error LED lights up
with the current set value displayed.
During the error LED is lighted, when [START] key is pressed again,
execution is performed again.
Operation
The operation is similar to simulation 46-01. (In MANUAL)
OK/ERR display in AUTO.
Document guide
The trailing edge has a scale
Table glass
The trailing edge void on the first printing surface
 is shown above.
Paper 
Void position to be checked
Scale (S-D mode)
Mode
Display 
item
Default
LED
RSPF scan 
position auto 
adjustment
AUTO
1
COPY mode lamp
RSPF scan 
position manual 
adjustment
MANU
1
PRINT mode lamp
<When OK>
<When ERR>
53-08 SPF AUTO
AUTO  100% **    OK
53-08 SPF AUTO
AUTO  100% **    ERR
6cm or more is required.
MX-B201/B201D  ADJUSTMENTS  9 - 8
6. RSPF mode sub scanning direction 
magnification ratio adjustment
Note : Before performing this adjustment, be sure to check that the
OC mode adjustment in copying has been completed.
1) Put a scale on the original table as shown below, and make a
normal copy (100%) on the front and the back surfaces to
make a test chart. 
Note : Since the printed copy is used as a test chart, put the scale
in paralled with the edge lines.
2) Set the test chart on the RSPF and make a duplex copy (D-D or
D-S) in the normal ratio (100%).
3) Compare the scale image and the actual image.
If necessary, perform the following adjustment procedures.
4) Execute SIM 48-05.
5) The current sub scanning direction magnification ratio correc-
tion value is displayed in two digits on the display section.
6) Enter the set value and press the [START] key.
When adjusting the RSPF, use [2-SIDED COPY] key to select
single/duplex after entering the one page print mode, perform-
ing 2-page single copy.
When there is no document in RSPF, copy is inhibited.
<Adjustment specification>
7. Automatic black level correction
a. Cases when the adjustment is required
1) When the main PWB is replaced.
2) When the EEPROM in the main PWB is replaced.
3) When "U2" trouble occurs.
4) When repairing or replacing the optical section.
b. Adjustment procedure
Used to acquire the black level target value used for the black level
adjustment of white balance.
When SIM 63-02 is executed, the current correction value is dis-
played in 3 digits of 12bit hexadecimal number.
Place the gray gradation chart (UKOG-0162FCZZ) used as the
correction document so that the density 10 (black side) comes on
the left side and that the chart is upside down at the center of the
plate left center.
When START key is pressed, the mirror base unit scans the chart
and calculates the correction value.
After completion of correction, the corrected value is displayed on
the display section.
Default: 0
If the value is set to the default, operation is made with 0x60.
c. Operation
1) Initial display
2) [ENTER]/[START] key: Correction start
<During canceling - When [Clear]/[Clear All] key is pressed->
After canceling, the machine goes into the sub code entry standby
mode. 
3) After execution
3) In case of an error
Mode
Display item Default
Sub scan magnification ratio adjustment on 
the surface of RSPF document
SIDE1
50
Sub scan magnification ratio adjustment on 
the surface of RSPF document
SIDE2
50
Adjustment mode
Spec value
SIM
Set value
Setting 
range
Sub scanning 
direction 
magnification ratio 
(RSPF mode)
At normal: 
±1.0%
48-5 Add 1: 
0.1% increase
Reduce 1: 
0.1% decrease
1 – 99
63-02 BLACK LEVEL
               0
63-02 BLACK LEVEL
EXECUTING...
THE JOB IS BEING
CANCELED.
63-02 BLACK LEVEL
             *** OK 
63-02 BLACK LEVEL
             *** ERR
Chart back surface
 
10
MX-B201/B201D  SIMULATION, TROUBLE CODES  10 - 1
:'11/Oct/17
1
[10] SIMULATION, TROUBLE CODES
1. Entering the simulation mode
To enter the serviceman simulation mode, press the keys as fol-
lows:
[#] key 
 [
] key 
 [Clear] key 
 [
] key
To cancel the simulation mode, press the [Clear All] key.
2. Key rule
3. List of simulations
[Numeric] key:
Entry of MAIN CODE/SUB CODE
Selection of an item
Setup of an adjustment value in case of 
simulations for adjustment
[
]  [
]  key:
Selection of MAIN CODE/SUB CODE
Selection of an item
[ENTER]/[START] key:Settlement
<In case of simulations for print>
[ENTER] key: Settlement (Without print)
[START] key: Settlement / Print
[Clear] key:
(Interrupting operation check) Returns to the 
upper hierarchy.
In case of simulation of operation check, 
terminates the operations.
[Clear All] key: 
Exits from the simulation mode.
For a simulation of adjustment, the display 
returns to the initial display (00-00).
 Sim 
No.
Sub 
code
Operation
01
01
Mirror scan operation
02
Mirror home position sensor (MHPS) status display
06
Aging of mirror scanning
02
01
RSPF aging operation
02
RSPF sensor status display 
03
RSPF Motor ON
08
RSPF paper feed solenoid operation check 
09
RSPF reverse solenoid operation check 
03
03
Shifter operation check
05
01
Operation panel display check
02
Fusing lamp, cooling fan operation check
03
Copy lamp ON
06
01
Paper feed solenoid ON
02
Resist solenoid ON
07
01
Warm-up display and aging with jam
06
Intermittent aging
08
Shift to copy with the warm-up display
08
01
Developing bias
02
Main charger (Grid high)
03
Grid voltage (Low)
06
Transfer charger
09
01
Duplex motor normal rotation operation check 
(MX-B201D only) 
02
Duplex motor reverse operation check 
(MX-B201D only) 
04
Duplex motor rotation speed adjustment
(MX-B201D only)
10
Toner motor aging
14
Cancel of troubles other than U2
16
Cancel of U2 trouble
20
01
Maintenance counter clear
21
01
Maintenance cycle setting
1
1
1
22
01
Maintenance counter display
02
Maintenance preset display
04
JAM total counter display
05
Total counter display
06
Developer counter display
08
RSPF counter display
11
FAX-related counter display
12
Drum counter display
13
CRUM type display
14
ROM version display
16
Duplex counter display (MX-B201D only)
17
Copy counter display
18
Printer counter display
19
Scanner mode counter display
20
Password display
21
Scanner counter display
22
RSPF JAM counter display
24
01
JAM total counter clear
04
RSPF counter clear
05
Duplex counter clear (MX-B201D only)
06
Developer counter clear
07
Drum counter clear
08
Copy counter clear
09
Printer counter clear
10
FAX counter clear (When MX-FX12 is installed)
13
Scanner counter clear
14
RSPF JAM total counter clear 
15
Scanner mode counter clear
25
01
Main motor operation check 
(Cooling fan motor rotation check)
10
Polygon motor ON
26
02
RSPF setup
03
2ND TRAY setup
04
Machine duplex setup (DPLX)
06
Destination setup
07
Machine conditions check
20
Rear edge void setup
30
CE mark support control ON/OFF
37
Cancel of stop at developer life over
39
Memory capacity check
40
Polygon motor OFF time setup (Time required for 
turning OFF after completion of printing)
42
Transfer ON timing control setup
43
Side void setup
54
γ
 life correction setting
62
Energy-save mode copy lamp setup
69
Use to set the operation conditions for toner near 
end
30
01
Paper sensor status display
41
06
OC cover float detection level adjustment 
(Only when RSPF installed)
07
OC cover float detection margin setting 
(Only when RSPF installed)
43
01
Fusing temperature setting (Normal copy)
04
Fusing temperature setting in multi copy
05
Fusing temperature setup in duplex copy 
(MX-B201D only)
14
Fusing start temperature setting
 Sim 
No.
Sub 
code
Operation
1
1
1
1
1
1
Page of 127