MX-7000N  SIMULATION  7 – 117
25
1, 2
(*)
Volume setting of call sound 
(medium)
Volume level 3
0 0
0
Volume level 5
Related to BZ
Calling sound/ 
Communication end 
sound (Normal, 
Error)
Volume level 5
0 1
1
Volume level 7
1 0
Volume level 9
1 1
3, 4
(*)
Volume setting of call sound 
(small)
Volume level 0 
(no sound)
0 0
1
Volume level 2
Related to BZ
Calling sound/ 
Communication end 
sound (Normal, 
Error)
Volume level 1
0 1
0
Volume level 2
1 0
Volume level 3
1 1
5, 6
(*)
Volume setting of line 
monitor sound (large)
Volume level 9
0 0
1
Volume level 15
Line Monitor sound
When on-hook
Receiver off-hook 
warning sound
Volume level 11
0 1
1
Volume level 13
1 0
Volume level 15
1 1
7, 8
(*)
Volume setting of line 
monitor sound (medium)
Volume level 5
0 0
1
Volume level11
Line Monitor sound
When on-hook
Receiver off-hook 
warning sound
Volume level 7
0 1
1
Volume level 9
1 0
Volume level11
1 1
26
1, 2
(*)
Volume setting of line 
monitor sound (small)
Volume level 1
0 0
1
Volume level 5
Line Monitor sound
When on-hook
Receiver off-hook 
warning sound
Volume level 3
0 1
0
Volume level 5
1 0
Volume level 7
1 1
3
Not used
0
4
Remote changeover 
permitted
1: Changeover enable 
for call-out/call-in
0: Changeover enable 
only for call-in
0
Only for call-in
North America: This 
SW is ignored and 
changeover is 
enabled for call-out/
call-in.
5 - 7
Setting of call time (T0 timer 
setting) in automatic 
transmission
Setting range <Binary input>
(Rusia) 30 seconds to 35 seconds: 
5 seconds intervals
(China) 30 seconds to 45 seconds
(Other country) 30 seconds to 60 seconds: 
15 seconds intervals
"001": 35 seconds 
(Rusia)
"001": 45 seconds 
(Other country)
For outside the set 
range, the default 
value is used.
8
External telephone setting 
when no sound is set
1: No sound priority
0: Priority on external 
telephone send
0
Priority on 
external telephone 
send
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
27
1 - 8
External telephone off-hook 
detection time
Setting range
Binary input
0ms to 2550ms
10ms intervals
0
300ms
0
0
1
1
1
1
0
28
1 - 8
Not used
0
29
1 - 8
Not used
0
1
0
1
1
0
1
0
30
1 - 8
Not used
0
0
0
0
0
0
1
0
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
MX-7000N  SIMULATION  7 – 118
31
1 - 4
Not used
"1100": France/Germany
"0000": Other country
5
Document content print 
when sending (PC-Fax 
(Internet Fax) report table)
1: Print
0: Not print
0
Not print
6 - 8
Not used
1
0
1
32
1 - 4
T1 timer setting
Setting range
Binary input
30 to 105 seconds
5 seconds intervals
0
40 seconds
0
1
0
5 - 8
Not used
0
0
0
0
33
1, 2
T4 timer setting 
Timer during automatic 
operation
3 seconds
0 0
0
3 seconds
+1.5 seconds at 
times of manual 
operation
4 seconds
0 1
0
5 seconds
1 0
6 seconds
1 1
3
Not used
0
4
Selection of date and 
transmission source print 
language <Format>
1: North American 
format
0: Follows the date 
format setting.
0
Follows the date 
format setting.
5
EOL detection timer
1: 25 seconds
0: 13 seconds
0
13 seconds
6 - 8
Not used
"010": North America
"011": Taiwan
"100": Thailand/Rusia/South Africa
"001": Other country
34
1, 2
Not used
0
0
3 - 6
Modem transmission speed 
(Other than V.34) (DCS)
V.27ter
2400bps
0 0 0 0
1
V.17 14400bps
Setting in 
communication 
other than V.34
V.29
9600bps
0 0 0 1
0
V.27ter
4800bps
0 0 1 0
0
V.29
7200bps
0 0 1 1
0
V.33
14400bps
0 1 0 0
V.17
14400bps
0 1 0 1
V.33
12000bps
0 1 1 0
V.17
14400bps
0 1 1 1
V.17
14400bps
1 0 0 0
V.17
9600bps
1 0 0 1
V.17
12000bps
1 0 1 0
V.17
7200bps
1 0 1 1
V.17
14400bps
1 1 0 0
V.17
14400bps
1 1 0 1
V.17
14400bps
1 1 1 0
V.17
14400bps
1 1 1 1
7, 8
Fixing of modem speed 
during reception (Other than 
V.34) (DIS)
Not fixed
0 0
0
Not fixed
Setting in 
communication 
other than V.34
Max .speed in 
reception
V.29-9600bps
0 1
0
V.27ter-4800bps
1 0
V.17-14400bps
1 1
35
1, 2
Coding capacity during 
transmission and reception 
(V.34 communication) 
(reflected in DIS/DCS/DTC)
JBIG/MMR/MR/MH
0 0
0
JBIG/MMR/MR/
MH
MMR/MR/MH
0 1
0
MR/MH
1 0
MH
1 1
3, 4
Coding capacity during 
transmission and reception 
(other than V.34 
communication) (reflected 
in DIS/DCS/DTC)
JBIG/MMR/MR/MH
0 0
0
JBIG/MMR/MR/
MH
MMR/MR/MH
0 1
0
MR/MH
1 0
MH
1 1
5, 6
Not used
1
1
7, 8
Image capacity when 
polling (Reflected in DTC)
Very fine
0 0
0
Very fine
Fine
0 1
0
Small letters
1 0
Ordinary lettering
1 1
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
MX-7000N  SIMULATION  7 – 119
36
1 - 7
Not used
0
0
0
0
0
1
0
8
Confirmation of DIS 
reception when sending
1: Twice
0: Once for NFS 
reception, twice for DIS 
reception
0
Once for NFS 
reception, twice 
for DIS reception
Enable for other 
than V.34
37
1 - 8
Not used
0
1
0
1
1
0
0
0
38
1, 2
Protocol monitor
No
0 0
0
No
Yes
1 0
0
Only at times of error
1 1
3
Line monitor display
1: Yes
0: No
0
No
4
EEPROM access prohibited
1: Access prohibited
0: Access permitted
0
Access permitted
5
Not used
0
6
SDT signal detection
1: Yes
0: No
0
No
7, 8
Timer setting (V.21-FSK) 
between flag-adrs
6 seconds
0 0
0
20 seconds
Enable for other 
than V.34
20 seconds
0 1
1
30 seconds
1 0
120 seconds
1 1
39
1
Echo countermeasure (CED 
tone sending interval) when 
receiving
1: 500ms
0: 75ms
0
75ms
2
Echo countermeasure 
(setting of hold time 
between DIS reception and 
sending of signal) when 
transmitting
1: 800ms
0: 500ms
0
500ms
Enable for other 
than V.34
3 - 6
Not used
0
0
0
1
7, 8
RTN sending line error rate
6line
0 0
1
60line
Number of error 
lines in the STD 
standard
12line
0 1
0
60line
1 0
120line
1 1
40
1
CSI sending
1: No
0: Yes
0
Yes
2, 3
CED signal sending time
3 seconds
0 0
0
3 seconds
Setting for the 
ANSam signal is 
performed using a 
separate SW 51-7, 
8 (V.8 mode 
ANSam signal 
sending time).
4 seconds
0 1
0
5 seconds
1 0
No
1 1
4
CED/ANSam detection time
1: 1000ms
0: 500ms
0
500ms
5, 6
Waiting time for start of 
CED/ANSam sending
2.25 seconds
0 0
0
2.25 seconds
3 seconds
0 1
0
4 seconds
1 0
7, 8
Not used
0
0
41
1, 2
Start of CNG sending
0.5 seconds
0 0
"11": 2.0 seconds 
(North America/
Taiwan/Middle East/
Other3/Rusia)
"00": 0.5 seconds 
(Other country)
1.0 second
0 1
1.5 seconds
1 0
2.0 seconds
1 1
3
Time between DCS-TCF
1: 150ms
0: 75ms
0
75ms
4 - 8
Not used
0
1
0
0
0
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
MX-7000N  SIMULATION  7 – 120
42
1, 2
RCP sending count
3 times
0 0
0
3 times
6 times
0 1
0
9 times
1 0
12 times
1 1
3
RTC EOL sending count
1: 12 times
0: 6 times
0
6 times
4
F.A.S.T function
1: Yes
0: No
0
No
Valid only in North 
America.
5 - 8
Not used
0
1
1
1
43
1
V.34 mode function 
(including polling when 
calling)
1: V.34 invalid
0: V.34 valid
0
V.34 valid
2
V.34 mode function (on call 
arrival)
1: V.34 invalid
0: V.34 valid
0
V.34 valid
3
V.34 mode function at times 
of manual communication
1: V.34 invalid
0: V.34 valid
0
V.34 valid
4
Primary channel return 
mode setting
1: PPh
0: Sh
1
PPh
5, 6
External telephone off-hook 
detection time when 
simulated voltage is applied
48ms
0 0
0
96ms
96ms
0 1
1
200ms
1 0
300ms
1 1
7
Reversion from the energy 
saving state (excluding 
preheat) when the external 
telephone is off-hook
1: Revert
0: Do not revert
1
Revert
8
Not used
0
44
1
Echo suppressor tone 
setting No. 1
1: Without V33
0: With V33
0
With V33
2
Echo suppressor tone 
setting No. 2
1: Without V17
0: With V17
0
With V17
3
Echo suppressor tone 
setting No. 3
1: Without V29
0: With V29
1
Without V29
4
Echo suppressor tone 
setting No. 4
1: Without V27
0: With V27
0
With V27
5 - 8
Not used
0
1
1
1
45
1
Error handling when 
transmission and receiving 
RTN
1: Do not recognize error
0: Recognize errors
0
Recognize errors
2
Reception gain changeover 
when receiving
1: EYE-Q check only
0: "0" Reception & EYE-
Q check
0
"0" Reception & 
EYE-Q
3, 4
Transmission cable 
amplitude equalizer
0dB
0 0
0
0dB
4dB
0 1
0
8dB
1 0
12dB
1 1
5 - 8
Not used
0
0
0
0
46
1 - 4
V.34 mode transmission 
speed
Transmission speed = 2400(bps) x N
Example: 2400(bps) x 12 = 28800(bps)
2400 (bps) when N=0
33600 (bps) when N=15
1
33600(bps)
When set to 2400 
bps, "Symbol Rate" 
for V.34 send must 
be set to Disable.
1
1
0
5 - 8
V.34 mode receiving speed
Receiving speed = 2400(bps) x N
Example: 2400(bps) x 12 = 28800(bps)
2400 (bps) when N=0
33600 (bps) when N=15
1
33600(bps)
When set to 2400 
bps, V.34 Symbol 
Rate Mask (when 
reception) must be 
also changed.
1
1
0
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
Page of 127
Display

Click on the first or last page to see other MX-5500N / MX-6200N / MX-7000N (serv.man46) service manuals if exist.