Sharp MX-5500N / MX-6200N / MX-7000N (serv.man25) Peripheral ▷ View online
33
Removing and replacing Fiery X3eTY2 components
T
O
REPLACE
THE
EXHAUST
FAN
1.
Position the fan against the side of the pan.
When correctly positioned, the airflow arrow on the side of the fan should point
toward the vent holes in the side of the pan, and the fan cable should reach its connector
on the motherboard.
toward the vent holes in the side of the pan, and the fan cable should reach its connector
on the motherboard.
2.
Align the four holes on the fan with the four holes in the side of the pan, and secure the
fan with the four rivets that you removed earlier (see Figure Q on page 32).
fan with the four rivets that you removed earlier (see Figure Q on page 32).
Hold the fan firmly against the side of the pan, and push each rivet all the way until it
snaps into locked position. Make sure that the exhaust fan is tightly secured to the pan.
snaps into locked position. Make sure that the exhaust fan is tightly secured to the pan.
3.
Connect the 3-pin fan connector into connector FAN3 on the motherboard.
4.
Reassemble the Fiery X3eTY2 and verify its functionality (see page 42).
Power supply
The power supply is fan-cooled and rated at 180 watts, with an automatic input voltage
selection circuit. The input voltage is 100-240VAC.
selection circuit. The input voltage is 100-240VAC.
Do not open the power supply for service or troubleshooting purposes. Opening the
power supply voids the warranty.
power supply voids the warranty.
This section includes the following topics:
• “To remove the power supply”
• “To replace the power supply” on page 35
T
O
REMOVE
THE
POWER
SUPPLY
1.
Access and open the Fiery X3eTY2, as described on page 8.
2.
Remove the 20-pin power cable from the motherboard.
3.
Remove the 4-pin power cable from the motherboard.
4.
Remove the power cable from the power connector on the HDD.
5.
Remove the black and white power wires that connect to the leads on the power switch.
34
Removing and replacing Fiery X3eTY2 components
6.
Remove the three screws that attach the power supply to the side of the pan.
Then remove the two screws that attach the power supply to the base of the pan
(see Figure R).
Then remove the two screws that attach the power supply to the base of the pan
(see Figure R).
Set the screws aside so you can replace them later.
7.
Gently lift the power supply out of the pan.
F
IGURE
R
Removing the power supply
Screw (1 of 5)
35
Removing and replacing Fiery X3eTY2 components
T
O
REPLACE
THE
POWER
SUPPLY
1.
Place the power supply inside the pan (see Figure R on page 34).
Align the mounting holes in the power supply with the holes in the side and base of
the pan.
the pan.
2.
Using the five screws that you removed earlier, secure the power supply to the side and
base of the pan.
base of the pan.
3.
Connect the black and white power wires to the lower leads on the power switch,
as shown in Figure S.
as shown in Figure S.
F
IGURE
S
Connecting to the power switch
Connect black wire to
lower lead for OFF (O)
lower lead for OFF (O)
Connect white wire to
lower lead for ON (|)
OFF
ON
Power switch leads
36
Removing and replacing Fiery X3eTY2 components
4.
Connect the HDD power cable to the SATA power connector on the HDD:
Always connect power to the SATA power connector on the HDD. Do not use the
PATA (4-pin) power connector, if it is present on the HDD. Do not connect power to
both the SATA and PATA power connectors on the HDD. An incorrect power
connection results in system errors.
PATA (4-pin) power connector, if it is present on the HDD. Do not connect power to
both the SATA and PATA power connectors on the HDD. An incorrect power
connection results in system errors.
5.
Connect the 4-pin (2x2) power cable to its connector on the motherboard (see page 11).
6.
Connect the 20-pin power cable to its connector on the motherboard (see page 11).
7.
Make sure all power connectors are properly aligned and securely connected.
8.
Replace any tie wraps that you removed or cut while removing the power cables earlier.
For more information, see page 42.
9.
Reassemble the Fiery X3eTY2 and verify its functionality (see page 42).
Click on the first or last page to see other MX-5500N / MX-6200N / MX-7000N (serv.man25) service manuals if exist.