Removing and replacing Fiery X3eTY2 components
Several motherboard components are very close to the cooling assembly. Take care not to
damage these components when removing or replacing the cooling assembly.
damage these components when removing or replacing the cooling assembly.
Type A:
• Move the levers on the clamp to the
open position (spine up).
• Use a small flathead screwdriver to
bend the four hooks out of the slots
in the bracket one at a time. Make
sure not to damage the motherboard
as you bend the hooks out of the
bracket.
in the bracket one at a time. Make
sure not to damage the motherboard
as you bend the hooks out of the
bracket.
• Lift the cooling assembly off the CPU
socket and set it aside.
Use caution when lifting the cooling
assembly out of the bracket. The
thermal compound applied to the
bottom of the heatsink may damage
the CPU if the heatsink is removed
too forcefully.
Use caution when lifting the cooling
assembly out of the bracket. The
thermal compound applied to the
bottom of the heatsink may damage
the CPU if the heatsink is removed
too forcefully.
Lever open
Bracket
Clamp
Hooks
(2 of 4)
Lever open
Slot
Hook
26
Removing and replacing Fiery X3eTY2 components
Type B:
Two flexible metal clips secure the cooling
assembly to a plastic retention bracket
surrounding the CPU socket.
assembly to a plastic retention bracket
surrounding the CPU socket.
• To remove a clip, press down on the
thumb pad to relieve the clip’s tension
and then carefully move the clip arm
to disengage it from the slot in the
bracket.
and then carefully move the clip arm
to disengage it from the slot in the
bracket.
• Disengage the other clip arm from the
other slot in the bracket.
• Repeat this procedure to remove the
other clip.
• Carefully lift the cooling assembly off
the CPU socket and set it aside.
Use caution when lifting the cooling
assembly out of the bracket. The
thermal compound applied to the
bottom of the heatsink may damage
the CPU if the heatsink is removed
too forcefully.
assembly out of the bracket. The
thermal compound applied to the
bottom of the heatsink may damage
the CPU if the heatsink is removed
too forcefully.
N
OTE
:
You should not need to remove the
fan from the heatsink. Replacement
cooling assemblies ship with the fan
already attached.
cooling assemblies ship with the fan
already attached.
Clip
Thumb pad
Clip arm hooked
in bracket slot
Fan
Fan cable
27
Removing and replacing Fiery X3eTY2 components
T
O
REPLACE
THE
CPU
COOLING
ASSEMBLY
1.
Install the CPU cooling assembly:
• For the Type A cooling assembly, see the instructions below.
• For the Type B cooling assembly, see page 28.
Type A:
• Make sure the levers on the
clamp are in the open position (spine
up).
up).
• Align the heatsink so that the
fan cable is near the CPU fan
connector on the motherboard
(FAN1).
connector on the motherboard
(FAN1).
• Place the heatsink on the CPU and
inside the bracket.
Make sure the heatsink is fully seated
in the bracket on all
sides.
in the bracket on all
sides.
• Press down on the clamp until all four
hooks engage the slots in the bracket.
Avoid using excessive force when
pressing down on the clamp.
pressing down on the clamp.
• Close the levers simultaneously.
Closing the levers simultaneously
applies clamping force equally over
the CPU and bracket.
applies clamping force equally over
the CPU and bracket.
Bracket
Clamp
Hooks
(2 of 4)
Lever open
Lever open
CPU
Heatsink
Slot
(1 of 4)
(1 of 4)
Engage all four hooks,
and then close both
levers simultaneously.
and then close both
levers simultaneously.
Lever closed
Lever closed
28
Removing and replacing Fiery X3eTY2 components
Type B:
• Make sure the fan is securely attached
to the top of the heatsink.
N
OTE
:
In most cases, the fan is already
attached to the heatsink.
• Align the heatsink so that the fan
cable is near the CPU fan connector
(P1 FAN1) on the motherboard.
(P1 FAN1) on the motherboard.
• Place the heatsink on the CPU and
inside the bracket.
Make sure the heatsink is fully seated
in the bracket on all sides.
in the bracket on all sides.
• Insert the hook of the stationary clip
arm into a bracket slot.
• Allow the clip to lay across the groove
in the top of the heatsink.
• Hook the movable clip arm into the
bracket slot on the other side of the
heatsink.
heatsink.
• Orient the other clip in the opposite
direction and then install by repeating
the previous step. The “opposite”
orientation helps apply clamping
force equally over the heatsink.
the previous step. The “opposite”
orientation helps apply clamping
force equally over the heatsink.
Avoid using excessive force when
pressing down on the thumb tabs.
pressing down on the thumb tabs.
Thumb pad
Movable arm hooking
into bracket slot
Fan
Fan cable
Stationary
clip arm
Hook
Movable
clip arm
clip arm
Hook
Groove
Bracket
Stationary
arm
arm
Thumb pad
(opposite orientation)
(opposite orientation)
Clip