Sharp MX-5500N / MX-6200N / MX-7000N (serv.man25) Peripheral ▷ View online
5
Precautions
F
IGURE
B
Fiery X3eTY2 exploded view
i
Key
1. Cover
2. CPU clamp
3. CPU fan
4. CPU heatsink
5. DIMM
6. CPU
7. Battery
8. Motherboard
9. Interface board
10. Service board cable
11. HDD SATA data cable
12. Power supply
13. HDD bracket
14. HDD (hard disk drive)
15. Exhaust fan
16. Service board
17. Pan
N
OTE
:
The CPU cooling
assembly shown here may differ
from the cooling assembly
installed in your system. For
more information, see page 24.
from the cooling assembly
installed in your system. For
more information, see page 24.
4
1
8
10
9
5
2
3
7
11
12
13
14
15
16
6
17
6
Accessing the Fiery X3eTY2
Accessing the Fiery X3eTY2
To service the Fiery X3eTY2, you must perform the following tasks:
• Shut down the Fiery X3eTY2; power off both the Fiery X3eTY2 and the MFP.
• Remove the Fiery X3eTY2 from the MFP.
• Open the Fiery X3eTY2.
T
O
SHUT
DOWN
THE
F
IERY
X3
E
TY2
CAUTION:
Before you touch any parts inside the Fiery X3eTY2, make sure to wear an
ESD grounding wrist strap and follow all ESD safety precautions.
1.
Complete the steps listed below for your MFP model:
F
IGURE
C
Fiery Settings screen
MX-7000/6200/5500
MX-4500/3500
• Press the Copy tab on the MFP touch
panel.
• Press the Fiery icon at the bottom of
the touch panel.
• Press Fiery Settings.
The Fiery Settings screen appears.
• Press the System Settings button on
the MFP.
• On the touch panel, press Admin
Password and then press Password.
• On the touch panel, use the keyboard
to enter the administrator password for
the MFP. Press OK and then press OK
again at the next screen.
the MFP. Press OK and then press OK
again at the next screen.
This password is not the same as the
administrator password for the
Fiery X3eTY2.
administrator password for the
Fiery X3eTY2.
• At the System Settings screen, use the
arrows to scroll to Printer Settings and
press Printer Settings.
press Printer Settings.
• Press Fiery Settings.
The Fiery Settings screen appears.
Server Name
Idle
Idle
##### MB x.x
Info
Line selection
buttons
buttons
Up button
Down button
Menu button
7
Accessing the Fiery X3eTY2
2.
Make sure that the Fiery Settings screen reads Idle.
If Printing, Processing, or RIPping appears, the Fiery X3eTY2 is processing a job, and
you must wait until the system finishes and reaches Idle state.
you must wait until the system finishes and reaches Idle state.
3.
Press the menu button to display the Functions menu.
4.
Use the down button to scroll to Shut Down. Use the line selection button to select
Shut Down.
Shut Down.
The Shut Down menu appears with the following options:
• Restart Server: Resets the Fiery X3eTY2 server software without resetting the
underlying operating system.
• Shut Down System: Shuts down the Fiery X3eTY2 properly so that you can safely
power off the Fiery X3eTY2.
• Reboot System: Resets both the Fiery X3eTY2 and the underlying operating system,
and then reboots the Fiery X3eTY2.
5.
Use the line selection button to select Shut Down System.
6.
When a message appears prompting you to check the controller power switch or power
off the controller, press OK.
off the controller, press OK.
7.
Move the power switch on the Fiery X3eTY2 to the Off (O) position (see Figure D).
F
IGURE
D
Fiery X3eTY2 power panel
8.
Power off the MFP using the secondary power switch on the Control Panel, and then the
main power switch inside the front compartment.
main power switch inside the front compartment.
N
OTE
:
If you are recycling power, wait at least five seconds before powering back on.
Service switches
(may be covered)
Power switch
LED display
(may be covered)
Power connector
8
Accessing the Fiery X3eTY2
T
O
ACCESS
AND
OPEN
THE
F
IERY
X3
E
TY2
1.
Remove all external cables that are connected to the Fiery X3eTY2.
2.
Loosen the two upper mounting screws that secure the Fiery X3eTY2 to the back of the
MFP (see Figure E).
MFP (see Figure E).
Loosen, but do not remove, the upper mounting screws.
3.
Remove the two lower mounting screws that secure the Fiery X3eTY2 to the MFP.
4.
Lift up to release the Fiery X3eTY2 from the upper mounting screws. Remove the
Fiery X3eTY2 from the MFP.
Fiery X3eTY2 from the MFP.
F
IGURE
E
Removing the Fiery X3eTY2 from the MFP
Lift Fiery X3eTY2 to clear
upper mounting screws.
upper mounting screws.
Upper mounting screw
(1 of 2)
(1 of 2)
Lower mounting screw
(1 of 2)
(1 of 2)
Slotted hole (1 of 2)
N
OTE
:
The exact mounting
location of the
Fiery X3eTY2
on the MFP may differ from
that shown in this figure.
that shown in this figure.
Click on the first or last page to see other MX-5500N / MX-6200N / MX-7000N (serv.man25) service manuals if exist.