MX-6070V  MX-PN15B/C/D (PUNCH MODULE)  13 – 4
10) Take out the guide plate.
* The guide plate taken out is unnecessary. Be sure to ask the
customer if it should be disposed of.
11) Insert the hopper (Packed item No.4) from the paper feeding side
of the finisher.
12) Pass the harness to the outside of the blade.
13) Fix the inserted hopper with the screw.
14) Pass the harness through the clamp, and fix it.
15) Insert the stay from the front side of the finisher.
MX-6070V  MX-PN15B/C/D (PUNCH MODULE)  13 – 5
16) Place the shaft on the dent section at the right side of the plate.
17) Fix the front side with the screw.
18) Fix the right side with the screw.
19) Insert the guide plate (Packed item No. 3) from the right side of
the finisher.
20) Hook the pawls of the front side and right side to the flame of the
main unit, and fix the guide plate.
MX-6070V  MX-PN15B/C/D (PUNCH MODULE)  13 – 6
21) Fix the front side with the screw.
22) Install the resist sensor (Packed item No.2).
23) Insert the resist sensor (Packed item No.2) from the right side of
the finisher.
24) Fix the resist sensor (Packed item No.2) to the frame of the fin-
isher with the screw.
25) Connect the connector, fix it to the wire saddle.
Check that the guide plate 
passes through.
Front side
Right side
Resist sensor (No.2) connector
Hopper (no.4) connector
MX-6070V  MX-PN15B/C/D (PUNCH MODULE)  13 – 7
26) Install the punch unit (Packed item No.1).
27) Turn the punch unit with the operation section facing upward.
28) Insert the punch unit from the right side of the finisher.
29) Fix the punch unit to the frame of the finisher with the screws (x2).
30) Attach the stepping motor (Packed item No.7) from the right side
of the finisher.
31) Fix the stepping motor (Packed item No.7) to the frame of the fin-
isher with the screws (x2).
32) Connect each harness with the punch unit PWB.
Stepping motor (No.7) connector
Resist sensor (No.2) connector