Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man14) Service Manual ▷ View online
MX-4101N SIMULATION 6 – 49
<List of destination groups>
43-21
Purpose
Adjustment/Setup
Function (Purpose) Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-1) in each paper mode.
(H/H) for the fusing temperature setting
(SIM 43-1) in each paper mode.
Section
Operation/Procedure
1)
1)
Select an item to be set with [
↑] [↓] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
The set value in step 2 is saved.
Correction value: -49 - +49, 1 Count = 1
°C Change
Group 1
Japan
China
AB_B
Group 2
U.S.A.
Canada
Inch
Group 3
Europe
U.K.
AUS
AB_A
NOTE: When the destination is changed with SIM26-6 after changing this set value, the set values of the destination link items are reset to the default.
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(57(03$'-8670(17//
$˖
˷̚˹
˖+/B805($'<//
$˖
˖+/B/05($'<//
%˖
˖+/B(5($'<//
&˖
˖+/B803/$,1%://
'˖
˖+/B(3/$,1%://
)˖
˖+/B/03/$,1%://
(˖
˖+/B803/$,1&///
*˖
˖+/B/03/$,1&///
+˖
˖+/B(3/$,1&///
,˖
˖:$5083)8021+/B(ǂ7ǂ//
-˖
˖:$5083)802))7ǂ//
.˖
˖:$5083(1'7,0(//
/˖
2.
Correction
value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting
range
Default value
Destination
linkage
(NOTE)
(NOTE)
Group 1
Group 2
Group 3
A
HL_UM READY HH
Correction value for TH_UM set value in Ready standby
under HH environment
under HH environment
1 - 99
50
50
50
{
B
HL_LM READY HH
Correction value for TH_LM set value in Ready standby
under HH environment
under HH environment
1 - 99
50
50
50
{
C
HL_E READY HH
Correction value for TH_E set value in Ready standby
under HH environment
under HH environment
1 - 99
50
50
50
{
D
HL_UM PLAIN BW HH
Correction value for Black-White plain paper TH_UM set
value under HH environment
value under HH environment
1 - 99
50
50
50
{
E
HL_LM PLAIN BW HH
Correction value for Black-White plain paper TH_LM set
value under HH environment
value under HH environment
1 - 99
50
50
50
{
F
HL_E PLAIN BW HH
Correction value for Black-White plain paper TH_E set
value under HH environment
value under HH environment
1 - 99
50
50
50
{
G
HL_UM PLAIN CL HH
Correction value for Color plain paper TH_UM set value
under HH environment
under HH environment
1 - 99
50
50
50
{
H
HL_LM PLAIN CL HH
Correction value for Color plain paper TH_LM set value
under HH environment
under HH environment
1 - 99
50
50
50
{
I
HL_E PLAIN CL HH
Correction value for Color plain paper TH_E set value
under HH environment
under HH environment
1 - 99
50
50
50
{
J
WARMUP FUMON HL_E T HH
Correction value for fusing motor pre-rotation start TH_E
set value under HH environment
set value under HH environment
1 - 99
50
50
50
–
K
WARMUP FUMOFF T HH
Fusing motor prior rotation completion time under HH
environment
environment
1 - 99
50
50
50
–
L
WARMUP END TIME HH
Correction value for warm-up complete time under HH
environment
environment
1 - 99
50
50
50
–
M
HL_UM HEAVY HH
Correction value for heavy paper TH_UM set value under
HH environment
HH environment
1 - 99
50
50
50
–
N
HL_LM HEAVY HH
Correction value for heavy paper TH_LM set value under
HH environment
HH environment
1 - 99
50
50
50
–
O
HL_E HEAVY HH
Correction value for heavy paper TH_E set value under HH
environment
environment
1 - 99
50
50
50
–
P
HL_UM OHP HH
Correction value for OHP TH_UM set value under HH
environment
environment
1 - 99
50
50
50
–
Q
HL_LM OHP HH
Correction value for OHP TH_LM set value under HH
environment
environment
1 - 99
50
50
50
–
MX-4101N SIMULATION 6 – 50
* Item L: 1 Count = 1s Change
Correction value for the other items: 1 count for 1
°C change
<Code descriptions>
<List of destination groups>
R
HL_E OHP HH
Correction value for OHP TH_E set value under HH
environment
environment
1 - 99
50
50
50
–
S
HL_UM ENVELOPE HH
Correction value for envelope TH_UM set value under HH
environment
environment
1 - 99
50
50
50
–
T
HL_LM ENVELOPE HH
Correction value for envelope TH_LM set value under HH
environment
environment
1 - 99
50
50
50
–
U
HL_E ENVELOPE HH
Correction value for envelope TH_E set value under HH
environment
environment
1 - 99
50
50
50
–
V
HL_UM GLOSS HH
Correction value for glossy paper TH_UM set value under
HH environment
HH environment
1 - 99
50
50
50
–
W
HL_LM GLOSS HH
Correction value for glossy paper TH_LM set value under
HH environment
HH environment
1 - 99
50
50
50
–
X
HL_E GLOSS HH
Correction value for glossy paper TH_E set value under HH
environment
environment
1 - 99
50
50
50
–
Y
HL_UM E-STAR HH
Correction value for preheating TH_UM set value under HH
environment
environment
1 - 99
50
50
50
–
Z
HL_E E-STAR HH
Correction value for preheating TH_E set value under HH
environment
environment
1 - 99
50
50
50
–
AA
PRE-JOB HH
Correction value for resetting from preheating
TH_UM+TH_E set value under HH environment
TH_UM+TH_E set value under HH environment
1 - 99
50
50
50
–
AB
HL_LM E-STAR HH
Correction value for preheating TH_LM set value under HH
environment
environment
1 - 99
50
50
50
–
AC
HL UM HEAVY2 CL HH
Correction value for heavy paper 2 TH_UM set value under
HH environment
HH environment
1 - 99
50
50
50
–
AD
HL LM HEAVY2 CL HH
Correction value for heavy paper 2 TH_LM set value under
HH environment
HH environment
1 - 99
50
50
50
–
AE
HL E HEAVY2 CL HH
Correction value for heavy paper 2 TH_E set value under
HH environment
HH environment
1 - 99
50
50
50
–
AF
HL_UM WARMUP_120L HH
Correction value for TH_UM set value in WarmUp at 120
°C
or below under HH environment
1 - 99
50
50
50
–
AG
HL_LM WARMUP_120L HH
Correction value for TH_LM set value in WarmUp at 120
°C
or below under HH environment
1 - 99
50
50
50
–
AH
HL_E WARMUP_120L HH
Correction value for TH_E set value in WarmUp at 120
°C or
below under HH environment
1 - 99
50
50
50
–
AI
LO_WARMUP_TIME_HH
Correction value for AF-AH applying time (timer from Ready
complete) under HH environment
complete) under HH environment
1 - 99
50
50
50
–
AJ
HL_UM WARMUP_120H HH
Correction value for TH_UM set value in WarmUp at 120
°C
or above under HH environment
1 - 99
50
50
50
–
AK
HL_LM WARMUP_120H HH
Correction value for TH_LM set value in WarmUp at 120
°C
or above under HH environment
1 - 99
50
50
50
–
AL
HL_E WARMUP_120H HH
Correction value for TH_E set value in WarmUp at 120
°C or
above under HH environment
1 - 99
50
50
50
–
AM
HI_WU_TIME_HH
Correction value for AJ-AL applying time (timer from Ready
complete) under HH environment
complete) under HH environment
1 - 99
50
50
50
–
AN
HI_WU_FM_ON_TMP_HH
Correction value for FM prior rotation start TH_E in
WarmUp at alpha
WarmUp at alpha
°C or above under HH environment
1 - 99
50
50
50
–
AO
HI_WU_END_TIME_HH
Correction value for WarmUp completion time in WarmUp
at alpha
at alpha
°C or above under HH environment
1 - 99
50
50
50
–
AP
HI_WU_JOB_SET_TMP_HH
Correction value for Job Enable TH_UM temperature in
WarmUp at alpha
WarmUp at alpha
°C or above under HH environment
1 - 99
50
50
50
–
AQ
HI_WARMUP_BORDER_HH
Correction value for the threshold value alpha applying
SIM43-1-AN - AP under HH environment
SIM43-1-AN - AP under HH environment
1 - 99
50
50
50
–
AR
LO_WU_JOB_SET_TMP_HH
Correction value for Job Enable TH_UM temperature in
WarmUp at alpha
WarmUp at alpha
°C or below under HH environment
1 - 99
50
50
50
–
AS
ROT_TIME_AFTER_JOB_HH
Correction value for the after rotation time when completing
a job under HH environment
a job under HH environment
1 - 99
50
50
50
–
Item/Display
Content
Setting
range
Default value
Destination
linkage
(NOTE)
(NOTE)
Group 1
Group 2
Group 3
TH_UM
Fusing upper thermister main center
HL_UM
Heater lamp upper main
TH_LM
Fusing lower thermister main
HL_LM
Heater lamp lower main
TH_E
Fusing thermister external
HL_E
Heater lamp external
Group 1
Japan
China
AB_B
Group 2
U.S.A.
Canada
Inch
Group 3
Europe
U.K.
AUS
AB_A
NOTE: When the destination is changed with SIM26-6 after changing this set value, the set values of the destination link items are reset to the default.
MX-4101N SIMULATION 6 – 51
43-22
Purpose
Adjustment/Setup
Function (Purpose) Used to set the environment correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-4) in each paper mode.
L) for the fusing temperature setting (SIM
43-4) in each paper mode.
Section
Operation/Procedure
1)
1)
Select an item to be set with [
↑] [↓] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
The set value in step 2 is saved.
Correction value: -49 - +49, 1 Count = 1
°C Change
* Items D, H: 1 Count = 1s Change
Correction value for the other items: 1 count for 1
°C change
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(57(03$'-8670(17++
$˖
˷̚˹
˖+/B805($'<++
$˖
˖+/B/05($'<++
%˖
˖+/B(5($'<++
&˖
˖+/B803/$,1%:++
'˖
˖+/B(3/$,1%:++
)˖
˖+/B/03/$,1%:++
(˖
˖+/B803/$,1&/++
*˖
˖+/B/03/$,1&/++
+˖
˖+/B(3/$,1&/++
,˖
˖:$5083)8021+/B(7++
-˖
˖:$5083)802))7++
.˖
˖:$5083(1'7,0(++
/˖
2.
Correction
value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting
range
Default value
Destination
linkage
(NOTE)
(NOTE)
Group 1
Group 2
Group 3
A
HL_UM PLAIN BW DUP LL
Correction value for upper TH_UM Black-White plain paper
duplex under LL environment
duplex under LL environment
1 - 99
55
55
55
{
B
HL_LM PLAIN BW DUP LL
Correction value for lower TH_LM Black-White plain paper
duplex under LL environment
duplex under LL environment
1 - 99
55
55
55
{
C
HL_E PLAIN BW DUP LL
Correction value for upper TH_E Black-White plain paper
duplex under LL environment
duplex under LL environment
1 - 99
55
55
55
{
D
PLAIN BW DUP APP CNT LL
Correction value for applying number of sheets in Black-
White plain paper duplex under LL environment
White plain paper duplex under LL environment
1 - 99
50
50
50
{
E
HL_UM PLAIN CL DUP LL
Correction value for upper TH_UM Color plain paper duplex
under LL environment
under LL environment
1 - 99
55
55
55
{
F
HL_LM PLAIN CL DUP LL
Correction value for lower TH_LM Color plain paper duplex
under LL environment
under LL environment
1 - 99
55
55
55
{
G
HL_E PLAIN CL DUP LL
Correction value for upper TH_E Color plain paper duplex
under LL environment
under LL environment
1 - 99
50
50
50
{
H
PLAIN CL DUP APP CNT LL
Correction value for applying number of sheets in Color
plain paper duplex under LL environment
plain paper duplex under LL environment
1 - 99
50
50
50
{
I
HL_UM HEAVY BW DUP LL
Correction value for upper TH_UM set value in Black-White
heavy paper duplex under LL environment
heavy paper duplex under LL environment
1 - 99
55
55
55
–
J
HL_LM HEAVY BW DUP LL
Correction value for lower TH_LM set value in Black-White
heavy paper duplex under LL environment
heavy paper duplex under LL environment
1 - 99
55
55
55
–
K
HL_E HEAVY BW DUP LL
Correction value for upper TH_E set value in Black-White
heavy paper duplex under LL environment
heavy paper duplex under LL environment
1 - 99
55
55
55
–
L
HEAVY BW DUP APP CNT LL
Correction value for applying number of sheets in Black-
White heavy paper duplex under LL environment
White heavy paper duplex under LL environment
1 - 99
50
50
50
–
M
HL_UM HEAVY CL DUP LL
Correction value for upper TH_UM set value in Color heavy
paper duplex under LL environment
paper duplex under LL environment
1 - 99
55
55
55
–
N
HL_LM HEAVY CL DUP LL
Correction value for lower TH_LM set value in Color heavy
paper duplex under LL environment
paper duplex under LL environment
1 - 99
55
55
55
–
O
HL_E HEAVY CL DUP LL
Correction value for upper TH_E set value in Color heavy
paper duplex under LL environment
paper duplex under LL environment
1 - 99
50
50
50
–
P
HEAVY CL DUP APP CNT LL
Correction value for applying number of sheets in Color
heavy paper duplex under LL environment
heavy paper duplex under LL environment
1 - 99
50
50
50
–
MX-4101N SIMULATION 6 – 52
<Code descriptions>
<List of destination groups>
43-23
Purpose
Adjustment/Setup
Function (Purpose) Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-4) in each paper mode.
(H/H) for the fusing temperature setting
(SIM 43-4) in each paper mode.
Section
Operation/Procedure
1)
1)
Select an item to be set with [
↑] [↓] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
The set value in step 2) is saved.
Correction value: -49 - +49, 1 Count = 1
°C Change
TH_UM
Fusing upper thermister main center
HL_UM
Heater lamp upper main
TH_LM
Fusing lower thermister main
HL_LM
Heater lamp lower main
TH_E
Fusing thermister external
HL_E
Heater lamp external
Group 1
Japan
China
AB_B
Group 2
U.S.A.
Canada
Inch
Group 3
Europe
U.K.
AUS
AB_A
NOTE: When the destination is changed with SIM26-6 after changing this set value, the set values of the destination link items are reset to the default.
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(57(03$'-8670(17//'83
$˖
˷̚˹
˖+/B803/$,1%:'83//
$˖
˖+/B/0ǂ3/$,1%:'83//
%˖
˖+/B(3/$,1%:'83//
&˖
˖3/$,1%:'83ǂ$33ǂ&17//
'˖
˖+/B/0ǂ3/$,1&/'83//
)˖
˖+/B80ǂ3/$,1&/'83//
(˖
˖+/B(ǂ3/$,1&/'83//
*˖
˖3/$,1&/'83ǂ$33ǂ&17//
+˖
˖+/B80+($9<%:'83//
,˖
˖+/B/0+($9<%:'83//
-˖
˖+/B(+($9<%:'83//
.˖
˖+($9<%:'83$33&17//
/˖
2.
Correction
value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting
range
Default value
Destination
linkage
(NOTE)
(NOTE)
Group 1
Group 2
Group 3
A
HL_UM PLAIN BW DUP HH
Correction value for TH_UM Black-White plain paper
duplex mode under HH environment
duplex mode under HH environment
1 - 99
55
55
55
{
B
HL_LM PLAIN BW DUP HH
Correction value for TH_LM Black-White plain paper
duplex mode under HH environment
duplex mode under HH environment
1 - 99
55
55
55
{
C
HL_E PLAIN BW DUP HH
Correction value for TH_E Black-White plain paper duplex
mode under HH environment
mode under HH environment
1 - 99
55
55
55
{
D
PLAIN BW DUP APP CNT HH
Correction value for applying number of sheets in
Black-White plain paper duplex under HH environment
Black-White plain paper duplex under HH environment
1 - 99
50
50
50
{
E
HL_UM PLAIN CL DUP HH
Correction value for TH_UM Color plain paper duplex
mode under HH environment
mode under HH environment
1 - 99
55
55
55
{
F
HL_LM PLAIN CL DUP HH
Correction value for TH_LM Color plain paper duplex
mode under HH environment
mode under HH environment
1 - 99
55
55
55
{
G
HL_E PLAIN CL DUP HH
Correction value for TH_E Color plain paper duplex mode
under HH environment
under HH environment
1 - 99
50
50
50
{
H
PLAIN CL DUP APP CNT HH
Correction value for applying number of sheets in
Color plain paper duplex under HH environment
Color plain paper duplex under HH environment
1 - 99
50
50
50
{
I
HL_UM HEAVY BW DUP HH
Correction value for Black-White heavy paper duplex
mode TH_UM set value under HH environment
mode TH_UM set value under HH environment
1 - 99
50
50
50
–
J
HL_LM HEAVY BW DUP HH
Correction value for Black-White heavy paper duplex
mode TH_LM set value under HH environment
mode TH_LM set value under HH environment
1 - 99
50
50
50
–
K
HL_E HEAVY BW DUP HH
Correction value for Black-White heavy paper duplex
mode TH_E set value under HH environment
mode TH_E set value under HH environment
1 - 99
50
50
50
–
L
HEAVY BW DUP APP CNT HH
Correction value for applying number of sheets in
Black-White heavy paper duplex under HH environment
Black-White heavy paper duplex under HH environment
1 - 99
50
50
50
–
M
HL_UM HEAVY CL DUP HH
Correction value for Color heavy paper duplex mode
TH_UM set value under HH environment
TH_UM set value under HH environment
1 - 99
50
50
50
–
Click on the first or last page to see other MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man14) service manuals if exist.