MX-4101N SIMULATION 6 – 53
* Items D, H: 1 Count = 1s Change
Correction value for the other items: 1 count for 1
°C change
<Code descriptions>
<List of destination groups>
43-24
Purpose
Adjustment/Setup
Function (Purpose) Used to set the correction of the tempera-
ture adjustment value of SIM 43-1 and 43-
4.
4.
Section
Operation/Procedure
1)
1)
Select an item to be set with [
↑] [↓] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
The set value in step 2 is saved.
Correction value: -49 - +49, 1 Count = 1
°C Change
N
HL_LM HEAVY CL DUP HH
Correction value for Color heavy paper duplex mode
TH_LM set value under HH environment
TH_LM set value under HH environment
1 - 99
50
50
50
–
O
HL_E HEAVY CL DUP HH
Correction value for Color heavy paper duplex mode
TH_E set value under HH environment
TH_E set value under HH environment
1 - 99
50
50
50
–
P
HEAVY CL DUP APP CNT HH
Correction value for applying number of sheets in
Color heavy paper duplex under HH environment
Color heavy paper duplex under HH environment
1 - 99
50
50
50
–
Item/Display
Content
Setting
range
Default value
Destination
linkage
(NOTE)
(NOTE)
Group 1
Group 2
Group 3
TH_UM
Fusing upper thermister main center
HL_UM
Heater lamp upper main
TH_LM
Fusing lower thermister main
HL_LM
Heater lamp lower main
TH_E
Fusing thermister external
HL_E
Heater lamp external
Group 1
Japan
China
AB_B
Group 2
U.S.A.
Canada
Inch
Group 3
Europe
U.K.
AUS
AB_A
NOTE: When the destination is changed with SIM26-6 after changing this set value, the set values of the destination link items are reset to the default.
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(57(03$'-8670(17++'83
$˖
˷̚˹
˖+/B803/$,1%:'83++
$˖
˖+/B/03/$,1%:'83++
%˖
˖+/B(3/$,1%:'83++
&˖
˖3/$,1%:'83$33&17++
'˖
˖+/B/03/$,1&/'83++
)˖
˖+/B803/$,1&/'83++
(˖
˖+/B(3/$,1&/'83++
*˖
˖3/$,1&/'83$33&17++
+˖
˖+/B80+($9<%:'83++
,˖
˖+/B/0+($9<%:'83++
-˖
˖+/B(+($9<%:'83++
.˖
˖+($9<%:'83$33ǂ&17++
/˖
2.
Correction
value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting
range
Default
value
A
NN_120_FUS_DUP_HL_UM&HL_E
Fusing temperature correction value NN environment power rising at less than 120
°C
common to item HL_UM and item HL_E
1 - 99
50
B
NN_120_FUS_DUP_HL_LM
Fusing temperature correction value NN environment power rising at less than 120
°C item
HL_LM
1 - 99
50
C
LL_120_FUS_DUP_HL_UM&HL_E
Fusing temperature correction value LL environment power rising at less than 120
°C
common to item HL_UM and item HL_E
1 - 99
50
D
LL_120_FUS_DUP_HL_LM
Fusing temperature correction value LL environment power rising at less than 120
°C item
HL_LM
1 - 99
50
E
HH_120_FUS_DUP_HL_UM&HL_E
Fusing temperature correction value HH environment power rising at less than 120
°C
common to item HL_UM and item HL_E
1 - 99
50
F
HH_120_FUS_DUP_HL_LM
Fusing temperature correction value HH environment power rising at less than 120
°C item
HL_LM
1 - 99
50
G
NN_120_FUS_DUP_CNT
Fusing duplex paper exit count under NN environment
1 - 60
5
H
LL_120_FUS_DUP_CNT
Fusing duplex paper exit count under LL environment
1 - 60
10
I
HH_120_FUS_DUP_CNT
Fusing duplex paper exit count under HH environment
1 - 60
5
J
COOL_DOWN_HEAVY
Cool down time heavy paper
1 - 60
15
K
COOL_DOWN_OHP
Cool down time OHP
1 - 60
30
MX-4101N SIMULATION 6 – 54
* Each temperature correction value: 1 count for 1
°C change in temperature control
* Each paper exit count: 1 count = 1 sheet change
* Each cool down time: 1 count = 1sec change
* Each cool down time: 1 count = 1sec change
<Code descriptions>
43-31
Purpose
Adjustment/Setup
Function (Purpose) Used to check the operation of the fusing
web cleaning motor.
Section
Fusing
Operation/Procedure
1)
1)
Press [EXECUTE] key.
Perform the fusing web cleaning motor drive.
Perform the fusing web cleaning motor drive.
2)
When driving the fusing web cleaning motor is completed,
"COMPLETE" is displayed.
"COMPLETE" is displayed.
* The fusing web unit is used by installing to the fusing unit. For
checking the fusing web cleaning motor rotation, remove the
whole fusing unit and check with the door open.
whole fusing unit and check with the door open.
L
COOL_DOWN_DEVELOP
Cool down time envelope
1 - 60
40
M
FUS MOTOR
Fusing web motor operating interval
1 - 20
6
N
NN_120_WUP_COMP_TH_E
Correction value for SIM43-4-C, G at 120
°C or below in N/N WarmUp
1 - 99
50
O
LL_120_WUP_COMP_TH_E
Correction value for SIM43-22-C, G at 120
°C or below in L/L WarmUp
1 - 99
50
P
HH_120_WUP_COMP_TH_E
Correction value for SIM43-23-C, G at 120
°C or below in H/H WarmUp
1 - 99
50
Q
HL UM THIN PAPER BW
Thin paper BW-TH_UM
70 - 230
165
R
HL LM THIN PAPER BW
Thin paper BW-TH_LM
30 - 200
120
S
HL E THIN PAPER BW
Thin paper BW-TH_E
70 - 230
195
T
HL UM THIN PAPER CL
Thin paper COL-TH_UM
70 - 230
165
U
HL LM THIN PAPER CL
Thin paper COL-TH_LM
30 - 200
120
V
HL E THIN PAPER CL
Thin paper COL-TH_E
70 - 230
195
W
HL UM THIN PAPER READY
Thin paper Ready-TH_UM
70 - 230
170
X
HL UM REC PAPER BW
Recycled paper BW-TH_UM
70 - 230
185
Y
HL LM REC PAPER BW
Recycled paper BW-TH_LM
30 - 200
125
Z
HL E REC PAPER BW
Recycled paper BW-TH_E
70 - 230
220
AA
HL UM REC PAPER CL
Recycled paper COL-TH_UM
70 - 230
185
AB
HL LM REC PAPER CL
Recycled paper COL-TH_LM
30 - 200
130
AC
HL E REC PAPER CL
Recycled paper COL-TH_E
70 - 230
220
AD
HL UM REC PAPER READY
Recycled paper Ready-TH_UM
70 - 230
180
TH_UM
Fusing upper thermister main center
HL_UM
Heater lamp upper main
TH_LM
Fusing lower thermister main
HL_LM
Heater lamp lower main
TH_E
Fusing thermister external
HL_E
Heater lamp external
Item/Display
Content
Setting
range
Default
value
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(57(035(6(7
$˖
˷̚˹
˖11BB)86B'83B+/B80 +/B(
$˖
˖11BB)86B'83B+/B/0
%˖
˖//BB)86B'83B+/B80 +/B(
&˖
˖//BB)86B'83B+/B/0
'˖
˖++BB)86B'83B+/B/0
)˖
˖++BB)86B'83B+/B80 +/B(
(˖
˖11BB)86B'83B&17
*˖
˖//BB)86B'83B&17
+˖
˖++BB)86B'83B&17
,˖
˖&22/B'2:1B+($9<
-˖
˖&22/B'2:1B2+3
.˖
˖&22/B'2:1B'(9(/23
/˖
2.
Fusing web unit
installation detection
state
Operation
Remark
Fusing web unit
installed
installed
Not operate
* During this operation,
the fusing web cleaning
feed counter is not
counted up.
feed counter is not
counted up.
Fusing web unit not
installed
installed
10sec continuous
rotation
rotation
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(5:(%&/($1,1*&+(&.
(;(&87(
MX-4101N SIMULATION 6 – 55
43-32
Purpose
Adjustment/Setup
Function (Purpose) Used to set various items related to the
forcible operation of web cleaning when job
end.
end.
Section
Fusing
Operation/Procedure
1)
1)
Select an item to be set with [
↑] [↓] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
The set value in step 2 is saved.
44
44-1
Purpose
Setting
Function (Purpose) Used to set each correction operation func-
tion in the image forming (process) section.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
ing/Transfer/Cleaning)
Operation/Procedure
1)
1)
Select an item to be set with the touch panel.
(The selected item is highlighted.)
(The selected item is highlighted.)
2)
Press [EXECUTE] key. (The set value is saved.)
NOTE: Set the items to the default values unless a change is spe-
cially required.
Item
Display
Item
Setting
range
Default
value
A
JOB END
COMP ACT
CHECK
COMP ACT
CHECK
Fusing web
motor forcible
operation
condition when
job end
motor forcible
operation
condition when
job end
Enable
0 - 1
0
1
Disable
1
B
JOB END
COMP ACT
INTERVAL
COMP ACT
INTERVAL
The fusing web motor is
forcibly operated when job
end.
forcibly operated when job
end.
1 - 200
100
Print quantity interval
C
JOB END
COMP ACT
CNT
COMP ACT
CNT
Number of forcible
operations of the fusing
web motor when job end
operations of the fusing
web motor when job end
1 - 5
1
Item/Display
Content
Setting
range
Default
value
NOTE
HV
Normal operation high
density process control
Enable/Disable setting
density process control
Enable/Disable setting
Normal
(Disable
: 1 : NO)
Reverse
Reverse
(Enable :
0 : YES)
Enable
HT
Normal operation half
tone process control
Enable/Disable setting
tone process control
Enable/Disable setting
Enable
TC
Transfer output
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
-2%(1':(%&/($1,1*&2038/625<&+(&.
$˖
˷̚˹
˖-2%(1'&203$&7&+(&.
$˖
˖-2%(1'&203$&7,17(59$/
%˖
˖-2%(1'&203$&7&17
&˖
ǂ
2.
MD VG
Membrane decrease
grid voltage correction
Enable/Disable setting
grid voltage correction
Enable/Disable setting
Normal
(Disable
: 1 : NO)
Reverse
(Enable :
0 : YES)
(Disable
: 1 : NO)
Reverse
(Enable :
0 : YES)
Enable
MD LD
Membrane laser power
voltage correction
Enable/Disable setting
voltage correction
Enable/Disable setting
Disable
MD EV
Membrane decrease
environment grid
voltage correction
Enable/Disable setting
environment grid
voltage correction
Enable/Disable setting
Enable
MD DL
Membrane decrease
discharge light quantity
correction
Enable/Disable setting
discharge light quantity
correction
Enable/Disable setting
Enable
MD DL EV
Membrane decrease
environment discharge
light quantity
correction
Enable/Disable setting
environment discharge
light quantity
correction
Enable/Disable setting
Disable
TN_HUM
Toner density humidity
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
TN_AREA
Toner density area
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
TN_LIFE
Toner density life
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
TN_COV
Toner density print
ratio correction
Enable/Disable setting
ratio correction
Enable/Disable setting
Enable
TN_PROCON
Toner density process
control correction
Enable/Disable setting
control correction
Enable/Disable setting
Enable
TN_ENV
Toner density
environment correction
Enable/Disable setting
environment correction
Enable/Disable setting
Enable
TN_DRIP
Toner density
correction
unconditional supply
Enable/Disable setting
correction
unconditional supply
Enable/Disable setting
Enable
TN_SPEND
Toner forcible
consumption mode
Enable/Disable setting
consumption mode
Enable/Disable setting
Disable
PHT
1pixel half tone
process control
correction
Enable/Disable setting
process control
correction
Enable/Disable setting
Disable
AR_AUTO
Auto registration
adjustment
Enable/Disable setting
adjustment
Enable/Disable setting
Enable
AR_ERROR
Auto registration
adjustment execution
error check
Enable/Disable setting
adjustment execution
error check
Enable/Disable setting
Enable
DM_PHASE
Drum phase fitting
Enable/Disable setting
Enable/Disable setting
Enable
SENSITIVITY
Toner density
correction
Enable/Disable setting
correction
Enable/Disable setting
Disable
PRT_HT
Half tone process
control printer
correction feedback
Enable/Disable setting
control printer
correction feedback
Enable/Disable setting
Enable
PTC_ENV
PTC environment
correction
Enable/Disable setting
correction
Enable/Disable setting
Enable
Enable:
Correc-
tion ON
Correc-
tion ON
PTC_LIFE
PTC life correction
Enable/Disable setting
Enable/Disable setting
Enable
Enable:
Correc-
tion ON
Correc-
tion ON
Item/Display
Content
Setting
range
Default
value
NOTE
MX-4101N SIMULATION 6 – 56
44-2
Purpose
Adjustment/Setup
Function (Purpose) Used to adjust the sensitivity of the image
density sensor (registration sensor).
Section
Process
Operation/Procedure
When [EXECUTE] key is pressed, the adjustment is executed auto-
matically.
After completion of the adjustment, the adjustment result is dis-
played.
If the adjustment is not executed normally, "ERROR" is displayed.
When [EXECUTE] key is pressed, the adjustment is executed auto-
matically.
After completion of the adjustment, the adjustment result is dis-
played.
If the adjustment is not executed normally, "ERROR" is displayed.
Item/Display
Content
Setting
range
Default
value
A
PCS_CL LED ADJ
Color sensor light
emitting quantity
adjustment value
emitting quantity
adjustment value
1 - 255
21
B
PCS_K LED ADJ
Black sensor light
emitting quantity
adjustment value
emitting quantity
adjustment value
1 - 255
21
C
PCS_CL DARK
Dark voltage of color
0 - 255
0
D
PCS_K DARK
Dark voltage of black
0 - 255
0
E
PCS_K GRND
Belt substrate when
the item B
adjustment is
completed.
the item B
adjustment is
completed.
0 - 255
0
F
PCS_K BELT MAX
Belt substrate input
max. value
max. value
0 - 255
0
G
PCS_K BELT MIN
Belt substrate input
min. value
min. value
0 - 255
0
H
PCS_K BELT DIF
Belt substrate input
difference
(Item E - Item F)
difference
(Item E - Item F)
0 - 255
0
I
REG_F LED ADJ
Registration sensor
light emitting
quantity adjustment
value F
light emitting
quantity adjustment
value F
1 - 255
56
J
REG_F DARK
Registration sensor
dark voltage F
dark voltage F
0 - 255
0
K
REG_F GRND
Belt substrate when
the item I adjustment
is completed.
the item I adjustment
is completed.
0 - 255
0
L
REG_R LED ADJ
Registration sensor
light emitting
quantity adjustment
value R
light emitting
quantity adjustment
value R
1 - 255
56
M
REG_R DARK
Registration sensor
dark voltage R
dark voltage R
0 - 255
0
N
REG_R GRND
Belt substrate when
the item J adjust-
ment is completed.
the item J adjust-
ment is completed.
0 - 256
0
O
REG_F BELT MAX
Belt substrate input
max. value (F side)
max. value (F side)
0 - 255
0
P
REG_F BELT MIN
Belt substrate input
min. value (F side)
min. value (F side)
0 - 255
0
Q
REG_F BELT DIF
Belt substrate input
difference
(Item O - Item P)
difference
(Item O - Item P)
0 - 255
0
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
02'(6(77,1*
(;(&87(
+9
+7
0'ǂ9*
7&
0'/'
0'(9
0''/(9
0''/
71B+80
71B$5($
71B&29
71B/,)(
71B352&21
71B(19
71B63(1'
71B'5,3
3+7
$5B$872
'0B3+$6(
$5B(5525
6(16,7,9,7<
357B+7
37&B(19
37&B(19
R
REG_R BELT MAX
Belt substrate input
max. value (R side)
max. value (R side)
0 - 255
0
S
REG_R BELT MIN
Belt substrate input
min. value (R side)
min. value (R side)
0 - 255
0
T
REG_R BELT DIF
Belt substrate input
difference
(Item R - Item S)
difference
(Item R - Item S)
0 - 255
0
U
REG_F PATCH (K)
Patch light receiving
potential F(K)
potential F(K)
0 - 255
0
V
REG_F PATCH (C)
Patch light receiving
potential F(C)
potential F(C)
0 - 255
0
W
REG_F PATCH (M)
Patch light receiving
potential F(M)
potential F(M)
0 - 255
0
X
REG_F PATCH (Y)
Patch light receiving
potential F(Y)
potential F(Y)
0 - 255
0
Y
REG_R PATCH (K)
Patch light receiving
potential R(K)
potential R(K)
0 - 255
0
Z
REG_R PATCH (C)
Patch light receiving
potential R(C)
potential R(C)
0 - 255
0
AA
REG_R PATCH (M)
Patch light receiving
potential R(M)
potential R(M)
0 - 255
0
AB
REG_R PATCH (Y)
Patch light receiving
potential R(Y)
potential R(Y)
0 - 255
0
Error name
Error content
Black sensor adjustment
abnormality
abnormality
PCS_K LED ADJ error
The target is not reached by 3 times of
retry.
The target is not reached by 3 times of
retry.
Color sensor adjustment
abnormality
abnormality
PCS_CL LED ADJ error
The target is not reached by 3 times of
retry.
The target is not reached by 3 times of
retry.
Substrate scan abnormality
PCS_K GRND error
Effective difference between the upper
and lower values of the belt substrate
circuit, outside the range
Effective difference between the upper
and lower values of the belt substrate
circuit, outside the range
Registration sensor F
adjustment abnormality
adjustment abnormality
REG_F LED ADJ error
The target is not reached by 3 times of
retry.
The target is not reached by 3 times of
retry.
Registration sensor R
adjustment abnormality
adjustment abnormality
REG_R LED ADJ error
The target is not reached by 3 times of
retry.
The target is not reached by 3 times of
retry.
Registration substrate F
scan abnormality
scan abnormality
REG_F GRND error
Effective difference between the upper
and lower values of the belt substrate
circuit, outside the range
Effective difference between the upper
and lower values of the belt substrate
circuit, outside the range
Registration substrate R
scan abnormality
scan abnormality
REG_R GRND error
Effective difference between the upper
and lower values of the belt substrate
circuit, outside the range
Effective difference between the upper
and lower values of the belt substrate
circuit, outside the range
Item/Display
Content
Setting
range
Default
value
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
352&21*$,1$'-8670(17
(;(&87(
3&6B&//('$'-
5(*B5/('$'-
3&6B./('$'-
5(*B5'$5.
3&6B&/'$5.
5(*B5*51'
3&6B.'$5.
3&6B.*51'
5(*B)%(/70$;
3&6B.%(/70$;
5(*B)%(/70,1
3&6B.%(/70,1
5(*B)%(/7',)
3&6B.%(/7',)
5(*B)/('$'-
5(*B5%(/70$;
5(*B)'$5.
5(*B5%(/70,1
5(*B)*51'
5(*B5%(/7',)
Click on the first or last page to see other MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man14) service manuals if exist.