MX-4101N  SIMULATION  6 – 45
<Code descriptions>
<List of destination groups>
N
HL_LM HEAVY PAPER
Heavy paper TH_LM set value
30 - 200
140
140
140
140
140
140
O
HL_E HEAVY PAPER
Heavy paper TH_E set value
70 - 230
220
220
220
220
220
220
P
HL_UM OHP PAPER
OHP-TH_UM set value
70 - 230
180
180
180
180
180
180
Q
HL_LM OHP PAPER
OHP-TH_LM set value
30 - 200
140
140
140
140
140
140
R
HL_E OHP PAPER
OHP-TH_E set value
70 - 230
220
220
220
220
220
220
S
HL_UM ENV PAPER
Envelope TH_UM set value
70 - 230
190
190
190
190
190
190
T
HL_LM ENV PAPER
Envelope TH_LM set value
30 - 200
140
140
140
140
140
140
U
HL_E ENV PAPER
Envelope TH_E set value
70 - 230
220
220
220
220
220
220
V
HL_UM GLOSS PAPER
Glossy paper TH_UM set value
70 - 230
185
185
185
185
185
185
W
HL_LM GLOSS PAPER
Glossy paper TH_LM set value
30 - 200
140
140
140
140
140
140
X
HL_E GLOSS PAPER
Glossy paper TH_E set value
70 - 230
220
220
220
220
220
220
Y
HL_UM E-STAR
Preheating TH_UM set value
30 - 200
150
150
160
160
160
160
{
Z
HL_E E-STAR
Preheating TH_E set value
30 - 200
150
150
160
160
160
160
{
AA
PRE-JOB
Resetting from preheating TH_UM, TH_E 
set value
30 - 200
170
170
170
170
170
170
{
AB
HL_LM E-STAR
Preheating TH_LM set value
30 - 200
100
100
100
100
100
100
{
AC
HL_UM HEAVY2 PAPER
Heavy paper 2 TH_UM set value
0 - 255
185
185
185
185
185
185
AD
HL_LM HEAVY2 PAPER
Heavy paper 2 TH_LM set value
0 - 255
140
140
140
140
140
140
AE
HL_E HEAVY2 PAPER
Heavy paper 2 TH_E set value
0 - 255
220
220
220
220
220
220
AF
HL_UM WARMUP_120L
TH_UM set value when WarmUp at 120
°C 
or below
70 - 230
170
170
180
180
180
180
{
AG
HL_LM WARMUP_120L
TH_LM set value when WarmUp at 120
°C 
or below
30 - 200
120
120
125
125
125
125
{
AH
HL_E WARMUP_120L
TH_E set value when WarmUp at 120
°C or 
below
70 - 230
220
220
225
225
225
225
{
AI
LO_WARMUP_TIME
AF-AH applying time (Timer from 
completion of Ready)
0  -  255
25
25
25
25
25
252
AJ
HL_UM WARMUP_120H
TH_UM set value when WarmUp at 120
°C 
or above
70 - 230
170
170
180
180
180
180
{
AK
HL_LM WARMUP_120H
TH_LM set value when WarmUp at 120
°C 
or above
30 - 200
120
120
125
125
125
125
{
AL
HL_E WARMUP_120H
TH_E set value when WarmUp at 120
°C or 
above
70 - 230
220
220
225
225
225
225
{
AM
HI_WARMUP_TIME
AJ-AL applying time (Timer from 
completion of Ready)
0  -  255
5
5
5
5
5
5
AN
HI_WU_FM_ON_TMP
FM prior rotation start TH_E when 
WarmUp at alpha 
°C or above
30 - 200
130
130
130
130
130
130
{
AO
HI_WU_END_TIME
WarmUp completion time when WarmUp 
at alpha 
°C or above
0  -  255
45
45
45
45
45
45
{
AP
HI_WU_JOB_SET_TMP
Job enable TH_UM temperature when 
WarmUp at alpha 
°C or above
70 - 230
165
165
175
175
180
175
{
AQ
HI_WARMUP_BORDER
Threshold value alpha to which SIM43-1-
AN - AP is applied
1  -  119
70
70
70
70
70
70
AR
LO_WU_JOB_SET_TMP
Job enable TH_UM temperature when 
WarmUp at alpha 
°C or below
70 - 230
170
185
175
185
185
185
{
AS
ROT_TIME_AFTER_JOB
After rotating time when a job is completed
0 - 255
15
15
15
15
15
15
Item/Display
Content
Setting 
range
Default value
Destination 
linkage 
(NOTE)
Group 1
Group 2
Group 3
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
TH_UM
Fusing upper thermister main center
HL_UM
Heater lamp upper main
TH_LM
Fusing lower thermister main
HL_LM
Heater lamp lower main
TH_E
Fusing thermister external
HL_E
Heater lamp external
Group 1
Japan
China
AB_B
Group 2
U.S.A.
Canada
Inch
Group 3
Europe
U.K.
AUS
AB_A
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing 
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed. 
NOTE: When the destination is changed with SIM26-6 after changing this set value, the set values of the destination link items are reset to the default. 
MX-4101N  SIMULATION  6 – 46
 
43-4
Purpose
Setting
Function (Purpose) Used to set the fusing temperature 2 in
each mode. (Continued from SIM 43-1.)
Section
Operation/Procedure
1)
Select an item to be set with [
↑] [↓] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
<Code descriptions>
<List of destination groups>
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(57(036(783)253$3(5
˷̚˹
˖+/B80ǂ5($'<
˖+/B/05($'<
˖+/B(5($'<
˖+/B803/$,13$3(5%:
˖+/B(3/$,13$3(5%:
˖+/B/03/$,13$3(5%:
˖+/B803/$,13$3(5&/
˖+/B/03/$,13$3(5&/
˖+/B(3/$,13$3(5&/
˖:$5083)8021+/B(7
˖:$5083)802))+/B/07
˖:$5083(1'7,0(
2.
Item/Display
Content
Setting 
range
Default value
Destination 
linkage 
(NOTE)
Group 1
Group 2
Group 3
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM PLAIN PAPER BW DUP
Black-White plain paper duplex 
TH_UM set value
70 - 230
165
175
170
175
170
175
{
B
HL_LM PLAIN PAPER BW DUP
Black-White plain paper duplex 
TH_LM set value
30 - 200
100
100
100
100
100
100
{
C
HL_E PLAIN PAPER BW DUP
Black-White plain paper duplex TH_E 
set value
70 - 230
220
220
220
220
220
220
{
D
PLAIN PAPER BW DUP APP CNT
Black-White plain paper duplex 
applying number of sheets
0 - 60
40
40
40
40
40
40
{
E
HL_UM PLAIN PAPER CL DUP
Color plain paper duplex TH_UM set 
value
70 - 230
165
175
170
175
170
175
{
F
HL_LM PLAIN PAPER CL DUP
Color plain paper duplex TH_LM set 
value
30 - 200
100
100
100
100
100
100
{
G
HL_E PLAIN PAPER CL DUP
Color plain paper duplex TH_E set 
value
70 - 230
220
220
220
220
220
220
{
H
PLAIN PAPER CL DUP APP CNT
Color plain paper duplex applying 
number of sheets
0 - 60
40
40
40
40
40
40
{
I
HL_UM HEAVY PAPER BW DUP
Black-White heavy paper duplex 
TH_UM set value
70 - 230
185
185
185
185
185
185
J
HL_LM HEAVY PAPER BW DUP
Black-White heavy paper duplex 
TH_LM set value
30 - 200
120
120
120
120
120
120
K
HL_E HEAVY PAPER BW DUP
Black-White heavy paper duplex TH_E 
set value
70 - 230
220
220
220
220
220
220
L
HEAVY PAPER BW DUP APP CNT
Black-White heavy paper duplex 
applying number of sheets
0  -  60
1
1
1
1
1
1
M
HL_UM HEAVY PAPER CL DUP
Color heavy paper duplex TH_UM set 
value
70 - 230
185
185
185
185
185
185
N
HL_LM HEAVY PAPER CL DUP
Color heavy paper duplex TH_LM set 
value
30 - 200
120
120
120
120
120
120
O
HL_E HEAVY PAPER CL DUP
Color heavy paper duplex TH_E set 
value
70 - 230
220
220
220
220
220
220
P
HEAVY PAPER CL DUP APP CNT
Color heavy paper duplex applying 
number of sheets
0  -  60
1
1
1
1
1
1
TH_UM
Fusing upper thermister main center
HL_UM
Heater lamp upper main
TH_LM
Fusing lower thermister main
HL_LM
Heater lamp lower main
TH_E
Fusing thermister external
HL_E
Heater lamp external
Group 1
Japan
China
AB_B
Group 2
U.S.A.
Canada
Inch
Group 3
Europe
U.K.
AUS
AB_A
MX-4101N  SIMULATION  6 – 47
 
43-20
Purpose
Adjustment/Setup
Function (Purpose) Used to set the environmental correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-1) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with [
↑] [↓] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
Correction value: -49 - +49, 1 Count = 1
°C Change
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing 
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed. 
NOTE: When the destination is changed with SIM26-6 after changing this set value, the set values of the destination link items are reset to the default. 
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(57(036(783)253$3(5
˷̚˹
˖+/B80ǂ3/$,13$3(5%:'83
˖+/B/0ǂ3/$,13$3(5%:'83
˖+/B(3/$,13$3(5%:'83
˖3/$,13$3(5%:'83$33&17
˖+/B/0ǂ3/$,13$3(5&/'83
˖+/B80ǂ3/$,13$3(5&/'83
˖+/B(3/$,13$3(5&/'83
˖3/$,13$3(5&/'83$33&17
˖+/B80ǂ+($9<3$3(5%:'83
˖+/B/0ǂ+($9<3$3(5%:'83
˖+/B(+($9<3$3(5%:'83
˖+($9<3$3(5%:'83$33&17
2.
Correction 
value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting 
range
Default value
Destination 
linkage 
(NOTE)
Group 1
Group 2
Group 3
A
HL_UM READY LL
Correction value for TH_UM set value in Ready standby 
under LL environment
1 - 99
55
55
55
{
B
HL_LM READY LL
Correction value for TH_LM set value in Ready standby 
under LL environment
1 - 99
55
55
55
{
C
HL_E READY LL
Correction value for TH_E set value in Ready standby 
under LL environment
1 - 99
55
55
55
{
D
HL_UM PLAIN BW LL
Correction value for Black-White plain paper TH_UM set 
value under LL environment
1 - 99
55
55
55
{
E
HL_LM PLAIN BW LL
Correction value for Black-White plain paper TH_LM set 
value under LL environment
1 - 99
55
55
55
{
F
HL_E PLAIN BW LL
Correction value for Black-White plain paper TH_E set 
value under LL environment
1 - 99
50
50
50
{
G
HL_UM PLAIN CL LL
Correction value for Color plain paper TH_UM set value 
under LL environment
1 - 99
55
55
55
{
H
HL_LM PLAIN CL LL
Correction value for Color plain paper TH_LM set value 
under LL environment
1 - 99
55
55
55
{
I
HL_E PLAIN CL LL
Correction value for Color plain paper TH_E set value 
under LL environment
1 - 99
50
50
50
{
J
WARMUP FUMON HL_E T LL
Correction value for fusing motor pre-rotation start TH_E 
set value under LL environment
1 - 99
45
45
45
K
WARMUP FUMOFF T LL
Fusing motor prior rotation completion time under LL 
environment
1 - 99
50
50
50
L
WARMUP END TIME LL
Correction value for warm-up complete time under LL 
environment
1 - 99
80
80
80
M
HL_UM HEAVY LL
Correction value for heavy paper TH_UM set value under 
LL environment
1 - 99
55
55
55
N
HL_LM HEAVY LL
Correction value for heavy paper TH_LM set value under 
LL environment
1 - 99
55
55
55
O
HL_E HEAVY LL
Correction value for heavy paper TH_E set value under LL 
environment
1 - 99
50
50
50
P
HL_UM OHP LL
Correction value for OHP TH_UM set value under LL 
environment
1 - 99
55
55
55
MX-4101N  SIMULATION  6 – 48
* Item L: 1 Count = 1s Change
Correction value for the other items: 1 count for 1
°C change
* Item D, F: When B5 size, correction of "-5" is made for item D and item F. 
* Item G, I: When B5 size, correction of "-5" is made for item G and item I. 
<Code descriptions>
Q
HL_LM OHP LL
Correction value for OHP TH_LM set value under LL 
environment
1 - 99
55
55
55
R
HL_E OHP LL
Correction value for OHP TH_E set value under LL 
environment
1 - 99
50
50
50
S
HL_UM ENVELOPE LL
Correction value for envelope TH_UM set value under LL 
environment
1 - 99
55
55
55
T
HL_LM ENVELOPE LL
Correction value for envelope TH_LM set value under LL 
environment
1 - 99
55
55
55
U
HL_E ENVELOPE LL
Correction value for envelope TH_E set value under LL 
environment
1 - 99
50
50
50
V
HL_UM GLOSS LL
Correction value for glossy paper TH_UM set value under 
LL environment
1 - 99
55
55
55
W
HL_LM GLOSS LL
Correction value for glossy paper TH_LM set value under 
LL environment
1 - 99
55
55
55
X
HL_E GLOSS LL
Correction value for glossy paper TH_E set value under LL 
environment
1 - 99
50
50
50
Y
HL_UM E-STAR LL
Correction value for preheating TH_UM set value under LL 
environment
1 - 99
55
55
55
Z
HL_E E-STAR LL
Correction value for preheating TH_E set value under LL 
environment
1 - 99
55
55
55
AA
PRE-JOB LL
Correction value for resetting from preheating 
TH_UM+TH_E set value under LL environment
1 - 99
55
55
55
AB
HL_LM E-STAR LL
Correction value for preheating TH_LM set value under LL 
environment
1 - 99
55
55
55
AC
HL UM HEAVY2 CL LL
Correction value for heavy paper 2 TH_UM set value under 
LL environment
1 - 99
55
55
55
AD
HL LM HEAVY2 CL LL
Correction value for heavy paper 2 TH_LM set value under 
LL environment
1 - 99
55
55
55
AE
HL E HEAVY2 CL LL
Correction value for heavy paper 2 TH_E set value under 
LL environment
1 - 99
50
50
50
AF
HL_UM WARMUP_120L LL
Correction value for TH_UM set value in WarmUp at 120
°C 
or below under LL environment
1 - 99
55
55
55
AG
HL_LM WARMUP_120L LL
Correction value for TH_LM set value in WarmUp at 120
°C 
or below under LL environment
1 - 99
55
55
55
AH
HL_E WARMUP_120L LL
Correction value for TH_E set value in WarmUp at 120
°C 
or below under LL environment
1 - 99
50
50
50
AI
LO_WARMUP_TIME_LL
Correction value for AF-AH applying time (timer from 
Ready complete) under LL environment
1 - 99
50
50
50
AJ
HL_UM WARMUP_120H LL
Correction value for TH_UM set value in WarmUp at 120
°C 
or above under LL environment
1 - 99
55
55
55
AK
HL_LM WARMUP_120H LL
Correction value for TH_LM set value in WarmUp at 120
°C 
or above under LL environment
1 - 99
55
55
55
AL
HL_E WARMUP_120H LL
Correction value for TH_E set value in WarmUp at 120
°C 
or above under LL environment
1 - 99
50
50
50
AM
HI_WU_TIME_LL
Correction value for AJ-AL applying time (timer from Ready 
complete) under LL environment
1 - 99
50
50
50
AN
HI_WU_FM_ON_TMP_LL
Correction value for FM prior rotation start TH_UM in 
WarmUp at alpha 
°C or above under LL environment
1 - 99
45
45
45
AO
HI_WU_END_TIME_LL
Correction value for WarmUp completion time in WarmUp 
at alpha 
°C or above under LL environment
1 - 99
50
50
50
AP
HI_WU_JOB_SET_TMP_LL
Correction value for Job Enable TH_UM temperature in at 
alpha 
°C or above under LL environment
1 - 99
55
55
55
AQ
HI_WARMUP_BORDER_LL
Correction value for the threshold value alpha applying 
SIM43-1-AN - AP under LL environment
1 - 99
50
50
50
AR
LO_WU_JOB_SET_TMP_LL
Correction value for Job Enable TH_UM temperature in at 
alpha 
°C or below under LL environment
1 - 99
55
55
55
AS
ROT_TIME_AFTER_JOB_LL
Correction value for the after rotation time when completing 
a job under LL environment
1 - 99
50
50
50
Item/Display
Content
Setting 
range
Default value
Destination 
linkage 
(NOTE)
Group 1
Group 2
Group 3
TH_UM
Fusing upper thermister main center
HL_UM
Heater lamp upper main
TH_LM
Fusing lower thermister main
HL_LM
Heater lamp lower main
TH_E
Fusing thermister external
HL_E
Heater lamp external
Page of 127
Display

Click on the first or last page to see other MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man14) service manuals if exist.