Sharp AR-FX13 Service Manual ▷ View online
AR-FX13 FAX SOFT SWITCH 5 - 4
∗: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden,
Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand
S
W
8
5
Remote select
function
function
1: Yes
0: No
Yes
1 1 1 1 1 1 1
Refer to User program
“REMOTE
RECEPTION
SELECT”.
“REMOTE
RECEPTION
SELECT”.
6
Number of times
of CNG detection
of CNG detection
Binary input
3 times
0 0 0 0 0 0 0 When a value outside
the set range is set,
the initial value is set.
the initial value is set.
7
Bit No.
Set range
Set range
6
7
8
1 to 4 times
1 1 1 1 1 1 1
8
1 1 1 1 1 1 1
S
W
9
1
Print of total
communication
time and total
pages
communication
time and total
pages
1: Yes
0: No
Yes
1 1 1 1 1 1 1
2
Inhibited to use
0 0 0 0 0 0 0
3
Ringing volume
pattern number
pattern number
Binary input
7 (A/B)
1 (C/D/E/F/G)
0 0 0 0 0 0 0 When a value outside
the set range is set,
the initial value is set.
the initial value is set.
4
Bit No.
Set range
Set range
3
4
5
6
7
8
Pattern No. 1 to 35
0 0 0 0 0 0 0
5
0 0 0 0 0 0 0
6
1 1 0 0 0 0 0
7
1 1 0 0 0 0 0
8
1 1 1 1 1 1 1
S
W
10
1
Measurement of
communication
time (image)
communication
time (image)
1: Yes
0: No
Yes
1 1 1 1 1 1 1
2
Sender’s
telephone number
registration
telephone number
registration
1: Inhibit
0: Allow
Allow
0 0 0 0 0 0 0
3
Inhibited to use
0 0 0 0 0 0 0
4
0 0 0 0 0 0 0
5
0 0 0 0 0 0 0
6
ECM byte/frame
1: 64 [bytes/frame]
0: 256 [bytes/frame]
256 [bytes/frame] 0 0 0 0 0 0 0
7
Inhibited to use
0 0 0 0 0 0 0
8
0 0 0 0 0 0 0
S
W
11
1
Inhibited to use
0 0 0 0 0 0 0
2
0 0 0 0 0 0 0
3
0 0 0 0 0 0 0
4
1 1 1 1 1 1 1
5
1 1 1 1 1 1 1
6
0 0 0 0 0 0 0
7
1 1 1 1 1 1 1
8
0 0 0 0 0 0 0
S
W
12
1
Call time setup in
automatic
transmission
(T0 timer setup)
automatic
transmission
(T0 timer setup)
Binary input
45sec
0 0 0 0 0 0 0 When a value outside
the set range is set,
the initial value is set.
the initial value is set.
2
Bit No.
Set range
Set range
1
2
3
4
30 to 75sec
5sec unit
N x 5 + 30sec
5sec unit
N x 5 + 30sec
0 0 0 0 0 0 0
3
1 1 1 1 1 1 1
4
1 1 1 1 1 1 1
5
Inhibited to use
0 0 0 0 0 0 0
6
CI detection
Bit No.
6
7
4 sine wave
0 0 0 0 0 0 0
When a value outside
the set range is set,
the initial value is set.
the set range is set,
the initial value is set.
4 sine wave
0
0
7
3 sine wave
1
0
0 0 0 0 0 0 0
2 sine wave
0
1
8
Inhibited to use
0 0 0 0 0 1 1
S
W
13
1
Inhibited to use
0 0 0 0 0 0 0
2
0 0 0 0 0 0 0
3
Ringing volume
Bit No.
3
4
Medium
1 1 1 1 1 1 1
Refer to User program
“RINGER VOLUME”.
“RINGER VOLUME”.
Silent
0
0
Small
0
1
4
Medium
1
0
0 0 0 0 0 0 0
Large
1
1
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
∗
Remark
A B C D E F G
AR-FX13 FAX SOFT SWITCH 5 - 5
∗: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden,
Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand
S
W
13
5
Speaker volume in
DTMF send
DTMF send
Bit No.
5
6
Medium
1 1 1 1 1 1 1
Not used
0
0
Small
0
1
6
Medium
1
0
0 0 0 0 0 0 0
Large
1
1
7
Inhibited to use
1 1 1 1 1 1 1
8
1 1 1 1 1 1 1
S
W
14
1
Inhibited to use
0 0 0 0 0 0 0
2
1 1 1 1 1 1 1
3
0 0 0 0 0 0 0
4
1 1 1 1 1 1 1
5
0 0 0 0 0 0 0
6
0 0 0 0 0 0 0
7
0 0 0 0 0 0 0
8
0 0 0 0 0 0 0
S
W
15
1
Busy tone
detection time
(Lower limit)
detection time
(Lower limit)
1: 350ms
0: 250ms
250ms
0 0 0 0 0 0 0
2
Busy tone
detection time
(Upper limit)
detection time
(Upper limit)
1: 650ms
0: 750ms
750ms
(A/B/C/D/E)
650ms (F/G)
0 0 0 0 0 1 1
3
Busy tone
detection time
(Lower limit 2)
detection time
(Lower limit 2)
1: 150ms
0: Follows SW15-1.
Follows SW15-1.
(A/B)
150ms
(C/D/E/F/G)
0 0 1 1 1 1 1
4
Signal send level
Binary input
–12dBm (A/B/G)
–11dBm
(C/D/E)
–9dBm (F)
0 0 0 0 0 0 0 When a value outside
the set range is set,
the initial value is set.
the initial value is set.
5
Bit No.
Set range
Set range
4
5
6
7
8
0 (0dBm) to 26 (–26dBm)
1 1 1 1 1 1 1
6
1 1 0 0 0 0 1
7
0 0 1 1 1 0 0
8
0 0 1 1 1 1 0
S
W
16
1
Modem speed
(V.33 mode or
less)
(V.33 mode or
less)
Bit No.
1
2
3
4
V.17 14.4kbps
1 1 1 1 1 1 1
V.27 2400bps
0
0
0
0
V.29 9600bps
0
0
0
1
2
V.27 4800bps
0
0
1
0
0 0 0 0 0 0 0
V.29 7200bps
0
0
1
1
V.33 14.4kbps
0
1
0
0
3
V.33 12.0kbps
0
1
1
0
0 0 0 0 0 0 0
V.17 9600bps
1
0
0
1
V.17 12.0kbps
1
0
1
0
4
V.17 7200bps
1
0
1
1
0 0 0 0 0 0 0
V.17 14.4kbps
Others
5
Modem speed in
reception fixed
reception fixed
Bit No.
5
6
No fixing
0 0 0 0 0 0 0
No fixing
0
0
V.29-9600BPS
0
1
6
V.27ter-4800BPS
1
0
0 0 0 0 0 0 0
V.17-14400BPS
1
1
7
Inhibited to use
0 0 0 0 0 0 0
8
0 0 0 0 0 0 0
S
W
17
1
Inhibited to use
0 0 0 0 0 0 0
2
MH fixed (Except
for SG3)
for SG3)
1: Yes
0: No (depending on the
other party’s machine)
other party’s machine)
No
0 0 0 0 0 0 0
3
ECM MMR mode
(Except for SG3)
(Except for SG3)
1: Yes
0: No
Yes
1 1 1 1 1 1 1
4
ECM JBIG mode
(Except for SG3)
(Except for SG3)
1: Yes
0: No
Yes
1 1 1 1 1 1 1
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
∗
Remark
A B C D E F G
AR-FX13 FAX SOFT SWITCH 5 - 6
∗: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden,
Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand
S
W
17
5
Inhibited to use
0 0 0 0 0 0 0
6
MH fixed (in SG3) 1: Yes
0: No (depending on the
other party’s machine)
other party’s machine)
No
0 0 0 0 0 0 0
7
ECM MMR mode
(in SG3)
(in SG3)
1: Yes
0: No
Yes
1 1 1 1 1 1 1
8
ECM JBIG mode
(in SG3)
(in SG3)
1: Yes
0: No
Yes
1 1 1 1 1 1 1
S
W
18
1
Inhibited to use
1 1 1 1 1 1 1
2
1 1 1 1 1 1 1
3
0 0 0 0 0 0 0
4
1 1 1 1 1 1 1
5
0 0 0 0 0 0 0
6
0 0 0 0 0 0 0
7
0 0 0 0 0 0 0
8
0 0 0 0 0 0 0
S
W
19
1
Inhibited to use
0 0 0 0 0 0 0
2
1 1 1 1 1 1 1
3
0 0 0 0 0 0 0
4
0 0 0 0 0 0 0
5
0 0 0 0 0 0 0
6
Recording table
automatic print
automatic print
1: Yes
0: No
No
0 0 0 0 0 0 0
Refer to User program
“AUTO LISTING”.
“AUTO LISTING”.
7
Inhibited to use
0 0 0 0 0 0 0
8
0 0 0 0 0 0 0
S
W
20
1
Line sound
monitor range
monitor range
Bit No.
1
2
OFF
0 0 0 0 0 0 0
When a value outside
the set range is set,
the initial value is set.
the set range is set,
the initial value is set.
OFF
0
0
2
Up to NSF signal send/
receive
receive
0
1
0 0 0 0 0 0 0
All
1
0
3
Line monitor
display
display
1: Yes
0: No
No
0 0 0 0 0 0 0
4
Inhibited to use
0 0 0 0 0 0 0
5
Receivable
memory capacity
memory capacity
1: 64Kbyte
0: 128Kbyte
128Kbyte
0 0 0 0 0 0 0
6
Inhibited to use
0 0 0 0 0 0 0
7
0 0 0 0 0 0 0
8
0 0 0 0 0 0 0
S
W
21
1
Interval between
completion of
communication
and the next call
completion of
communication
and the next call
Binary input
1sec (A/B)
6sec (C/D/E/F/G)
0 0 0 0 0 0 0
2
Bit No.
Set range
Set range
1
2
3
4
5
6
7
8
0 to 255sec
0 0 0 0 0 0 0
3
0 0 0 0 0 0 0
4
0 0 0 0 0 0 0
5
0 0 0 0 0 0 0
6
0 0 1 1 1 1 1
7
0 0 1 1 1 1 1
8
1 1 0 0 0 0 0
S
W
22
1
Inhibited to use
0 0 0 0 0 0 0
2
0 0 0 0 0 0 0
3
0 0 0 0 0 0 0
4
0 0 0 0 0 0 0
5
0 0 0 0 0 0 0
6
0 0 0 0 0 0 0
7
0 0 0 0 0 0 0
8
0 0 0 0 0 0 0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
∗
Remark
A B C D E F G
AR-FX13 FAX SOFT SWITCH 5 - 7
∗: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden,
Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand
S
W
23
1
Inhibited to use
0 0 0 0 0 0 0
2
0 0 0 0 0 0 0
3
0 0 0 0 0 0 0
4
0 0 0 0 0 0 0
5
0 0 0 0 0 0 0
6
0 0 0 0 0 0 0
7
0 0 0 0 0 0 0
8
0 0 0 0 0 0 0
S
W
24
1
Inhibited to use
0 0 0 0 0 0 0
2
0 0 0 0 0 0 0
3
Specified number
reception (ANTI
JUNK FAX)
reception (ANTI
JUNK FAX)
Bit No.
3
4
Not set.
0 0 0 0 0 0 0
Refer to Main menu
“ANTI JUNK FAX”.
When a value outside
the set range is set,
the initial value is set.
“ANTI JUNK FAX”.
When a value outside
the set range is set,
the initial value is set.
Not set.
0
0
4
Receive inhibit
0
1
0 0 0 0 0 0 0
5
Inhibited to use
0 0 0 0 0 0 0
6
Document output
setup in reception
setup in reception
1: Collective output after
completion of reception
completion of reception
0: Output after reception
of every page
of every page
Output after
reception of
reception of
every page (A/B)
Collective output
after completion
of reception
(C/D/E/F/G)
(C/D/E/F/G)
0 0 1 1 1 1 1
7
Inhibited to use
0 0 0 0 0 0 0
8
Automatic
reduction print
reduction print
1: Allow
0: Inhibit
Allow
1 1 1 1 1 1 1
Refer to User program
“AUTO RCV
REDUCE”.
“AUTO RCV
REDUCE”.
S
W
25
1
Automatic
reduction rate
setup
reduction rate
setup
Binary input
10%
1 1 1 1 1 1 1
2
Bit No.
Set range
Set range
1
2
3
4
0 to 15%
0 0 0 0 0 0 0
3
1 1 1 1 1 1 1
4
0 0 0 0 0 0 0
5
Transmission end
sound tone
sound tone
Bit No.
5
6
1000Hz
0 0 0 0 0 0 0
When a value outside
the set range is set,
the initial value is set.
the set range is set,
the initial value is set.
550Hz
0
0
6
1000Hz
0
1
1 1 1 1 1 1 1
1700Hz
1
0
7
Reception end
sound tone
sound tone
Bit No.
7
8
1000Hz
0 0 0 0 0 0 0
When a value outside
the set range is set,
the initial value is set.
the set range is set,
the initial value is set.
550Hz
0
0
8
1000Hz
0
1
1 1 1 1 1 1 1
1700Hz
1
0
S
W
26
1
Read completion
sound
sound
1: Mute
0: 1sec
1sec
0 0 0 0 0 0 0
2
Inhibited to use
0 0 0 0 0 0 0
3
Speaker volume
setup
setup
Bit No.
3
4
Small
0 0 0 0 0 0 0
Refer to User program
“BEEPER VOLUME
(send completion
sound / receive
completion sound /
scan completion
sound / alarm sound)”
“BEEPER VOLUME
(send completion
sound / receive
completion sound /
scan completion
sound / alarm sound)”
Silent
0
0
Small
0
1
4
Medium
1
0
1 1 1 1 1 1 1
Large
1
1
5
Inhibited to use
0 0 0 0 0 0 0
6
0 0 0 0 0 0 0
7
0 0 0 0 0 0 0
8
0 0 0 0 0 0 0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
∗
Remark
A B C D E F G