Sharp AR-FX13 Service Manual ▷ View online

AR-FX13  SIMULATION  4 - 7
66
11
300bps signal send 
(Max. value)
[Function]
Use to set the 300bps signal send (Max. value).
1: NO SIGNAL
2: 11111
3: 11110
4: 00000
5: 010101
6: 00001
[Operation]
12
300bps signal send 
(Soft SW set value)
[Function]
Use to set the 300bps signal send (Soft SW set value).
1: NO SIGNAL
2: 11111
3: 11110
4: 00000
5: 010101
6: 00001
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
2) [
] [
] key or after 2sec
Every time when [
]  key is pressed, the second line is changed in the sequence of No. 1 
→ 2
→ 3 → 4 → 5 → 6 → 1.
When [
] key is pressed, the sequence is reversed.
∗ [Clear] key: Returns to the main-sub code input display.
3) [ENTER]/[OK] key
∗ [Clear] key: Returns to "1) Initial display".
SELECT SIGNAL
PRESS 
SELECT SIGNAL (1-6)
1:NO SIGNAL
.....
SELECT SIGNAL (1-6)
6:00001
OUTPUTING SIGNAL MAX
PRESS CLEAR TO STOP
1) Initial display
2) [
] [
] key or after 2sec
Every time when [
]  key is pressed, the second line is changed in the sequence of No. 1 
→ 2
→ 3 → 4 → 5 → 6 → 1.
When [
] key is pressed, the sequence is reversed.
∗ [Clear] key: Returns to the main-sub code input display.
3) [ENTER]/[OK] key
∗ [Clear] key: Returns to "1) Initial display".
SELECT SIGNAL
PRESS 
SELECT SIGNAL (1-6)
1:NO SIGNAL
.....
SELECT SIGNAL (1-6)
6:00001
OUTPUTING SIGNAL SSW
PRESS CLEAR TO STOP
AR-FX13  SIMULATION  4 - 8
66
13
Dial test
[Function]
Use to the dial test.
[Operation]
17
DTMF signal send 
(Max. value)
[Function]
Use to set the DTMF signal send (Max. value).
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
■ Dial test (PULSE)
1) Initial display
∗ [Clear] key: Returns to the main-sub
code input display.
2) Select 1
3) Enter the make time in 2 digits.
XXXX: Default
∗ After deleting with [Clear] key, input
can be made.
4) [ENTER]/[OK] key
"yy" is the selected pulse 10 or 20.
"xx" is the input value.
∗ Select 2: Returns to “2)” display.
5) Select 1
Switched to 10/20PPS set with
pulse selection inside.
6) After setting
7) After completion of sending
∗ Select 2: Returns to “4)” display.
8) Select 1
After 2sec, returns to "1) Initial display".
SELECT SIGNAL
1:PULSE    2:DTMF
INPUT MAKE TIME
(0-15)            __
INPUT DIAL #
XXXX
SEND yyPPS xxms
1:YES 2:NO
SENDING yyPPS xxms
TERMINATE ?
1:YES 2:NO
TERMINATED
■ Dial test (DTMF)
1) Initial display
∗ [Clear] key: Returns to the main-sub code input dis-
play.
2)
Select 2
↓ Select 2
3)
Select 1
↓ Select 2
4) Select 1
XXXX: Default
∗ After deleting with [Clear] key, input can be made.
4) [ENTER]/[OK] key
"xx" indicates HI, and "yy" indicates Low Soft SW.
∗ Select 2: Returns to “4)” display.
5) Select 1
HI/LO is selected with the signal level inside.
6) After setting the signal send level
7) After completion of sending
∗ Select 2: Returns to “4)” display.
8) Select 1
After 2sec, returns to "1) Initial display".
SELECT SIGNAL
1:PULSE    2:DTMF
SELECT HIGH LEVEL
1:DEFAULT 2:SOFT SW.
INPUT VALUE
(0-15)            __
SELECT LOW LEVEL
1:DEFAULT 2:SOFT SW.
INPUT VALUE
(0-15)            __
INPUT DIAL #
XXXX
H:xx        L:yy
1:YES 2:NO
SENDING DTMF
TERMINATE ?
1:YES 2:NO
TERMINATED
1) Initial display
∗ [Clear] key: Returns to the main-sub code
input display.
2) [Numeric] key input
The content selected with signal send level
selection is set inside.
3) Communication is started after setting the
signal send level.
∗ [Clear] key: Returns to "1) Initial display".
INPUT DIAL #
SENDING SIGNAL MAX
PRESS CLEAR TO STOP
AR-FX13  SIMULATION  4 - 9
66
18
DTMF signal send 
(Soft SW set value)
[Function]
Use to set the DTMF signal send (Soft SW set value).
[Operation]
21
FAX information print
[Function]
Use to print the FAX information.
[Operation]
24
FAST SRAM clear
[Function]
Use to clear the FAST SRAM.
[Operation]
30
TEL/LIU status 
change check
[Function]
Use to check the TEL/LIU status change.
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
∗ [Clear] key: Returns to the main-sub code input
display.
2) [Numeric] key input
The content selected with signal send level
selection is set inside.
3) Communication is started after setting the
signal send level.
∗ [Clear] key: Returns to "1) Initial display".
INPUT DIAL #
SENDING SIGNAL SSW
PRESS CLEAR TO STOP
1) Initial display
2) [
] [
] key or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of 1 
→ 2 → 3
→ 1.
When [
] key is pressed, the sequence is reversed.
∗ [Clear] key: Returns to the main-sub code input display.
3) [ENTER]/[OK] key
• When print is allowed
After completion of printing,
main code and sub code input
display.
• When print is inhibited
After 2sec, FAX control is 
terminated.
SELECT REPORT (1-3)
PRESS 
SELECT REPORT (1-3)
1:USER SW. LIST
SELECT REPORT (1-3)
2:SOFT SW. LIST
SELECT REPORT (1-3)
3:PROTOCOL
PRINT STORED
CAN NOT PRINT
1) Initial display
2) After completion of clearing
After 2sec, main code and sub code input dis-
play.
CLEAR FAST SRAM
CLEARED
1) Initial display
The display is switched every 2sec.
∗ [Clear] key: Returns to the main-sub code input display.
HS2 :xxx  HS1 :xxx
RHS :xxx  EXHS:xxx
CHECKING
PRESS CLEAR TO STOP
AR-FX13  SIMULATION  4 - 10
66
33
Signal detection check
[Function]
Use to check the signal detection.
[Operation]
34
Communication time 
measurement
[Function]
Use to measurement the communication time.
[Operation]
37
Speaker sound 
volume setting
[Function]
Use to set the speaker sound volume.
1: NO SOUND
2: LOW
3: MID
4: HIGH
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
When a signal is detected, the display is changed from NONE to the following.
CI/CNG/CED/BT/DT/Flag/SDT/DTMF
∗ [Clear] key: Returns to the main-sub code input display.
CHECKING        NONE
PRESS CLEAR TO STOP
1) Initial display
"xx:xx:xx:xxx" indicates o'clock, minute, second, millisecond.
∗ [Clear] key: Returns to the main-sub code input display.
COMM. TIME
xx:xx:xx:xxx msec
1) Initial display
2) [
] [
] key or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of 1 
→ 2 → 3
→ 4 → 1.
When [
] key is pressed, the sequence is reversed.
∗ [Clear] key: Returns to the main-sub code input display.
3) [ENTER]/[OK] key
xxx: Set content
After 2sec, main code and sub code input display.