AR-FX13  SPECIFICATIONS  2 - 3
Incoming 
functions 
system
Incoming detection 
function
Call signal detection 
function
Call bell is distinguished from net call signals to judge 
incoming.
Remote select function 
by CNG detection
Receive is started when CNG signal is detected in 
standby with external telephone used.
Application 
incoming function
Distinctive Ringing 
function
(North America)
Conforms to the call distinguishing function provided 
by the local telephone company.
(Europe, Australia, New Zealand)
Only distinction of TEL/FAX (When FAX distinction of 
ON/OFF) (Default: OFF)
Call bell pattern
OFF/STANDARD/Pattern 1 - 5 (North America)
Incoming reject 
function
Incoming is rejected when remaining memory 
capacity is less than 7%.
Call sound volume 
adjustment function
Volume select
OFF/LOW/MIDDLE/HIGH
Alarm sound volume 
adjustment function 
Volume select
OFF/LOW/MIDDLE/HIGH
Key sound volume 
setting
Follows setting on the main unit.
Junk FAX protection 
function 
Junk stations are registered to be rejected.
Number of 
registrations
Max. 10 items
Receive 
functions 
system
Receive function
Receive standby mode
• Auto (AUTO)
• Manual (MAN.)
• Answering machine (A.M.)
Basic receive 
function
Auto receive function
The line is switched to FAX by detection of call signal. 
(receive standby mode)
Number of calls
AUTO: 0 - 9 times (Default: 2 times)
Tel/FAX auto select
No
Incoming reject 
conditions
• During Simulation by serviceman
• Insufficient memory capacity
• During  menu
• During memory status display
Manual receive 
function
Receive is manually started.
Number of calls 
0 - 9 times (Default: 0 times)
Memory receive 
function
Receive data are accumulated in memory, and 
outputted when output conditions are satisfied.
Substitution receive 
function
Countermeasure against print inhibit state.
• No recording paper
• Recording paper jam
• During copy/print job
• During printing by printer
• Cover open
• Paper empty, size error
Forcible memory 
receive function
No
Overtake output 
function
No
Receive document 
output function
Auto reduction/ divided 
receive function
Auto reduction function When the reference line number is in the specified 
range.
Divided receive 
function
When the reference line number exceeds the 
specified range.
Polling receive 
function (Send request 
function)
The remote machine must be provided with polling 
function. Communication is allowed with an other 
company machine.
Sequential send 
request (Polling) 
communication
Polling is made to two or more specified destinations. 
Number of items of destination registration: Max. 100 
items
Remote send
Scanned document data in memory are sent 
automatically by send request from the remote 
machine.
Protection function
• Check by sender number
• Check by allow number
Large item
Middle item
Small item
Sub item
Specifications
AR-FX13  SPECIFICATIONS  2 - 4
Receive 
functions 
system
Print system
Recording paper
Recordable size
A4/8.5" x 11"/8.5" x 14"
Recording paper 
setting
AUTO/TRAY 1/TRAY 2 (When the option installed)
(In AUTO, TRAY1 has priority.) (Default: AUTO) 
(North America)
Paper feed
Paper feed by tray (Excluding multi manual feed)
Recording paper size 
detection
The recording paper length is detected. If the size 
differs, a paper size error occurs.
Recording paper 
empty detection
Detected by a paper pickup error.
Duplex receive
Available only in the duplex function support models.
Transfer function
Receive data are transferred to the registered station.
Number of registered 
transfer destination
1 item
Registered telephone 
number
40 digits
Local transfer
Countermeasures against an error
• Paper jam
• No toner cartridge
• No toner
• During toner supply
• Toner empty
• No recording paper
Telephone 
functions 
system
Main unit 
telephone function
On-hook dial function
Yes
Manual redial function
Max. memory digit
50 digits
Display digits
End 20 digits
Pause function
Yes (Fixed to 2sec)
Pulse/Tone select 
function
Yes (Set by soft switch)
External telephone 
connection 
function
Select function by 
DTMF
Select number (1 digit) + [**] (0 - 9)
Record table 
system
Report list
Report output function
Report select
• TIMER LIST
• ACTIVITY REPORT
• TELEPHONE# LIST
• GROUP  LIST
• PASSCODE LIST
• JUNK FAX# LIST
• USER PROGRAM LIST
Recording table auto 
print function
Number of items
Auto print for every 50 items of send/receive total.
Communication report 
list
Report select
• Send report list
• Receive report list
• Serial broadcast send report list
• Image memory addition
Print status select
• ALWAYS PRINTS
• ERROR ONLY
• NEVER PRINTS
Large item
Middle item
Small item
Sub item
Specifications
AR-FX13  SPECIFICATIONS  2 - 5
Memory 
functions 
system
Memory outline
Memory capacity
Standard memory
2MB
Option
No
Document quantity to 
be stored
A4 standard documents 120 pages
Data storage area/ 
backup when service 
interruption (Recorded 
data, receive data)
Image data
Flash memory (Data are retained when the power is 
turned off or when the battery is exhausted.)
Data other than image
SRAM (Data are retained when the power is turned 
off, but deleted when the battery is exhausted with the 
power OFF.)
Treatment when 
memory full
Quick online
Memory full on the first 
page
Send cancel without call-out
Memory full on the 
second or later page
The line is shut-off after sending the last page of 
scanned data.
Memory send
Memory full on the first 
page
Send cancel
Memory full on the 
second or later page
Send/Cancel is selected depending on the select 
menu display.
Send: The line is shut off after sending the scanned 
data.
Cancel: Cancel even scanned data.
Memory status 
check function
Yes (The remaining memory capacity (%) is displayed 
on the LCD.)
Memory content 
check function
Not-sent job is displayed on the LCD. (Cancel is 
possible.)
Document jam
Error LED, LCD message are displayed.
Service 
functions 
system
Simulation 
function
Send/receive of specified signals, commands, and 
image data are performed without a remote machine.
Counter function
Communication 
counter
• Number of send pages
• Number of receive pages
• Number of output pages
• Send time
• Receive  time
Others
Environmental 
functions
Auto clear
Conforms to the main unit setting. When the 
operation is left for 1 min or more, the display returns 
to the main menu.
Auto shut -off
Conforms to the main unit setting.
Date and time 
setting function
(North America)
Month/ Day/ Year/ Day of week/ O'clock/ minute
(Europe, Australia, New Zealand)
Day/ Month/ Year/ Day of week/ O'clock/ minute
Image priority 
function
STANDARD/FINE/SUPER FINE
BEEP LENGTH 
(Communication 
end sound length) 
setting
3SEC/1SEC/NO BEEP
Auto summer time 
setting
(North America)
Second Sunday of March AM2:00 
→ 3:00,
First Sunday of November AM2:00 
→ 1:00
(Default: OFF)
(Europe)
Last Sunday of March AM1:00 
→ 2:00,
Last Sunday of October AM1:00 
→ 0:00
(Default: ON)
(Australia, New Zealand)
Last Sunday of October AM2:00 
→ 3:00,
Last Sunday of March AM3:00 
→ 2:00
(Default: ON)
Multi language 
function
Conforms to the main unit setting.
Large item
Middle item
Small item
Sub item
Specifications
AR-FX13  INSTALLATION PROCEDURE  3 - 1
[3] INSTALLATION PROCEDURE
<Before installation>
For improvement of workability, some description in this manual as
well as components and accessories may change without prior
notice. In this case, refer to the service manual.
Turn off the main switch of the copier and then remove the power
plug of the copier from the outlet.
1. Parts included
Remove all pieces of fixing tape and fixing materials from the 
finisher.
2. Installation procedure
(1) Detach the RSPF or OC.
Detach the RSPF or OC from the copier and softly place it on top
of the original table as shown below.
(2) Remove the rear cabinet.
1) Unscrew  the  screw  and  remove  the  rear  cabinet  shielding
plate. (Save the screw.)
2) Unscrew three screws and remove the rear cabinet. (Save the
screws.)
(3) Attach the speaker unit.
Attach the speaker unit using a supplied screw as shown below.
(4) Attach the FAX modem PWB.
1) When RSPF is installed, unscrew the screw holding the RSPF
ground terminal. (Save the screw.)
2) Insert two supplied screws and tighten them loosely as shown
below.
3) Attach the sponge around the bent portion of the FFC cable as
shown in the figure.
Cable: 1
Sponge: 1
FAX Modem PWB: 1
Key sheet: 1
FAX keyboard: 1
Ground angle: 1
Speaker unit: 1
Gasket: 2
Core: 1
Line cable: 1
Line Adapter: 1
(Australia/New Zealand)
Operation Manual: 1
Screws (M3x6): 5
For North America
Screws (M3x6): 6
For other than North America
North America
FCC label: 1
Australia/New Zealand
A-tick label: 1
1
2
2
2
3
1