Sharp AR-FX13 Service Manual ▷ View online

AR-FX13  SIMULATION  4 - 11
66
38
Time setting/check
[Function]
Use to check the time setting.
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
∗ [Clear] key: Returns to the main-sub code
input display.
2) Select 1
"xxxx.xx.xx(xxx)" is the current value. (No revi-
sion of display)
3)
Select 1
∗ Select 2: Returns to "1) Initial display".
4) Enter the year in 4 digits.
5) Enter the month in 2 digits.
6) Enter the day in 2 digits.
"xxxx.xx.xx(xxx) is the entered value.
∗ Select 2: Returns to "1) Initial display".
7) Select 1
After 2sec, returns to "1) Initial display".
2) Select 2
"xx:xx" is the current value.
3) Select 1
∗ Select 2: Returns to "1) Initial display".
4) Enter o'clock in 2 digits.
5) Enter minute in 2 digits.
"xx:xx" is the current value.
∗ Select 2: Returns to "1) Initial display".
6) Select 1
After 2sec, returns to "1) Initial display".
SELECT TO SET
1:DATE     2:TIME
xxxx.xx.xx(xxx)
CHANGE?   1:YES 2:NO
INPUT YEAR
(4 DIGITS)____.__.__
INPUT MONTH
(1-12)    1998.__.__
INPUT DAY
(1-31)    1998.01.__
xxxx.xx.xx(xxx)
STORED?   1:YES 2:NO
STORED
xx:xx
CHANGE?   1:YES 2:NO
INPUT HOUR
(0-24)         __:__
INPUT MINUTE
(00-59)        01:__
xx:xx
STORED?   1:YES 2:NO
STORED
AR-FX13  FAX SOFT SWITCH  5 - 1
[5] FAX SOFT SWITCH
1. FAX soft switch setting change quick reference table
Large item
Middle item
Switch content
Key operator
Soft SW No.
Usage
Dialing
Remote machine call 
disable
Pause time
None
SW 5-5 – 8
When dialing disable/when error dialing
Dial call signal
User program SW 48-1, 2
When dialing disable
DTMF-related item
None
SW 51-1 – 5
When dialing disable in PBX (private branch 
exchange/Fax service, etc.)
None
SW 53-5 – 8
When dialing disable in PBX (private branch 
exchange/Fax service, etc.)
None
SW 39-4 – 8
When dialing disable in PBX (private branch 
exchange/Fax service, etc.)
Pulse (10PPS)
None
SW 67-1 – 4
When pulse dialing disable
Signal detection
Busy tone detection
None
SW 7-3
When busy tone detection disable
Busy tone detection
None
SW 51-7, 8
When busy tone error is detected
Dial tone detection
None
SW 7-2
Redial
In case of an error
Resend interval
User program SW 4-1 – 4
When send errors occur frequently
(For the New Zealand models, tough it is set 
to 0, recall is performed in an interval of 
1min.)
In case of an error
Number of times of resend User program SW 40-1 – 8
When busy
Resend interval
User program SW 4-5 – 8
Whey busy occurs frequently
When busy
Number of times of resend User program SW 41-1 – 8
Arrival (Call-in) When CI detection 
disable
CI detection
None
SW 12-6, 7
No call-in
CI signal OFF detection 
time
None
SW 55-1 – 7
No call-in
External 
telephone
Setting of an external 
telephone connected
Yes/No
None
SW 47-2
When an external telephone is connected
Remote switch 
number
Entry of a 2-digit number
User program SW 2-5 – 8
When remote switch is erroneously 
detected
Remote switch 
setting
Yes/No
User program SW 8-5
When remote switch is erroneously 
detected
Communication General
Send level
None
SW 15-4 – 8
When the remote machine cannot receive 
signals in a proper level.
JBIG mode
None
SW 17-4, 8
When an error occurs in the JBIG mode
SG3
V34 mode function setup
None
SW 43-1
When SG3 communication error occurs 
frequently
V34 symbol rate
None
SW 43-4 – 6
When SG3 communication error occurs 
frequently
Transmission
G3/SG3
DIS reception check
None
SW 6-8
When an error occurs in phase B
Line equalizer
None
SW 59-5 – 8
Setting is made referring to the distance 
from the station when a communication 
trouble occurs.
SG3
V34 send speed
None
SW 44-1 – 4
When an error occurs in the SG3 
communication.
Manual send V34
None
SW 42-8
When an error occurs in the SG3 
communication in FAX service, etc.
G3
Modem send speed
None
SW 16-1 – 4
To specified/unspecified destination
RTN reception error
None
SW 52-5
When judged as “OK” though RTN is 
received
Reception
G3/SG3
CSI transmission
None
SW 6-3
Maximum reception length None
SW 7-6
When a document of 1m or longer is 
received
SG3
V34 reception speed
None
SW 44-5 – 8
When fall-down occurs frequently in the 
SG3 communication
G3
Countermeasure against 
echo in reception
None
SW 6-4
When an error occurs in phase B in 
reception
Modem speed in reception None
SW 16-5, 6
When the line quality is poor and a fall-back 
or an error occurs
EYE-Q check only
None
SW 72-1
Change in the detection method of training 
error
Reception print Paper selection
Automatic reduction print
User program SW 24-8
When reduction print is not made
Index
Index print setup
User program SW 32-6
When an index is attached to the reception 
data
AR-FX13  FAX SOFT SWITCH  5 - 2
2. Soft switch list
• When outside the set range, the default value is automatically set.
• Never change the soft switch setup which are inhibited to use.
∗: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, 
Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
A B C D E F G
S
W
1
1
Image quality 
priority selection
Bit No.
1
2
Normal
0 0 0 0 0 0 0
Refer to User program 
“RESO.PRIORITY”.
When a value outside 
the set range is set, 
the initial value is set.
Normal
0
0
2
Fine
0
1
0 0 0 0 0 0 0
Super fine
1
0
3
Inhibited to use
0 0 0 0 0 0 0
4
Auto/Manual 
default setup
1: Manual reception
0: Automatic reception
Automatic 
reception
0 0 0 0 0 0 0
Manual reception can 
be set only when 
external telephone is 
connected.
5
Send request 
protection
1: Not protected
0: Protected
Protected
0 0 0 0 0 0 0
Refer to User program 
“SECURITY 
SELECTION”.
6
Inhibited to use
0 0 0 0 0 0 0
7
0 0 0 0 0 0 0
8
0 0 0 0 0 0 0
S
W
2
1
Inhibited to use
0 0 0 0 0 0 0
2
0 0 0 0 0 0 0
3
0 0 0 0 0 0 0
4
0 0 0 0 0 0 0
5
Remote selection 
number setup
Binary input
5
0 0 0 0 0 0 0 Refer  to  User  program 
“REMOTE 
RECEPTION #”.
When a value outside 
the set range is set, 
the initial value is set.
6
Bit  No.
Set range
5
6
7
8
0 to 9
1 1 1 1 1 1 1
7
0 0 0 0 0 0 0
8
1 1 1 1 1 1 1
S
W
3
1
Density default 
setup
Bit  No.
1
2
3
4
5
Medium
0 0 0 0 0 0 0 When a value outside 
the set range is set, 
the initial value is set.
2
Light
1
0
0
0
0
0 0 0 0 0 0 0
3
Medium
0
0
1
0
0
1 1 1 1 1 1 1
4
Dark
0
0
0
0
1
0 0 0 0 0 0 0
5
0 0 0 0 0 0 0
6
Inhibited to use
0 0 1 1 1 1 1
7
Size specification
Bit No.
7
8
Conforms to the 
machine 
information.
0 0 0 0 0 0 0
When set to 
conformity to the 
machine information, 
if machine information 
is uncertain, set to 
centimeter size.
Centimeter size
0
0
Conforms to the machine 
information.
0
1
8
Inch size
1
0
1 1 1 1 1 1 1
Conforms to the machine 
information.
1
1
S
W
4
1
Recall interval in 
communication 
error
Binary input
1min
0 0 0 0 0 0 0
Refer to User program 
“RECALL INTERVAL 
(LINE ERROR)”.
When a value outside 
the set range is set, 
the initial value is set.
For the New Zealand 
models, tough it is set 
to 0, recall is 
performed in an 
interval of 1min.
Bit No.
Set range
1
2
3
4
1 to 15min
0: Recall immediately after 
cutting the line
2
0 0 0 0 0 0 0
3
0 0 0 0 0 0 0
4
1 1 1 1 1 1 1
5
Recall interval in 
busy
Binary input
3min
0 0 0 0 0 0 0 Refer  to  User  program 
“RECALL INTERVAL 
(BUSY)”.
When a value outside 
the set range is set, 
the initial value is set.
6
Bit  No.
Set range
5
6
7
8
1 to 15min
0 0 0 0 0 0 0
7
1 1 1 1 1 1 1
8
1 1 1 1 1 1 1
AR-FX13  FAX SOFT SWITCH  5 - 3
∗: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden, 
Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France / F = Australia / G = New Zealand
S
W
5
1
Inhibited to use
0 0 0 0 0 0 0
2
0 0 0 0 0 0 0
3
G3 send data 
accumulation wait 
time
Bit No.
3
4
6sec
0 0 0 0 0 0 0
6sec
0
0
5sec
0
1
4
4sec
1
0
0 0 0 0 0 0 0
3sec
1
1
5
Pause time setup
Binary input
2sec
0 0 0 0 0 0 0 When a value outside 
the set range is set, 
the initial value is set.
6
Bit  No.
Set range
5
6
7
8
1 to 15sec
0 0 0 0 0 0 0
7
1 1 1 1 1 1 1
8
0 0 0 0 0 0 0
S
W
6
1
ECM
1: Yes
0: No
Yes
1 1 1 1 1 1 1
2
CED signal send
1: Yes
0: No
Yes
1 1 1 1 1 1 1
3
CSI  transmission
1: Yes
0: No
Yes
1 1 1 1 1 1 1
4
DIS reception 
confirmation in G3 
send
1: 2 times
0: Once in NFS reception, 
2 time in DIS reception
Once in NFS 
reception, 2 time 
in DIS reception
0 0 0 0 0 0 0
5
Inhibited to use
0 0 0 0 0 0 0
6
EOL detection 
timer
1: 25sec
0: 13sec
13sec
0 0 0 0 0 0 0
7
Countermeasure 
for echo in 
reception (CED 
tone send interval)
1: 500ms
0: 75ms
500ms
1 1 1 1 1 1 1
8
Countermeasure 
for echo in 
transmission (After 
reception of DIS, 
hold time up to 
signal send is set.)
1: 800ms
0: 500ms
500ms
0 0 0 0 0 0 0
S
W
7
1
Dial tone ON/OFF 
detection time 
lower limit 
(Intermittent 
detection)
1: 300ms
0: 100ms
100ms
0 0 0 0 0 0 0
2
Dial tone detection 1: Yes
0: No
Yes (A)
No (B/C/D/E/F/G)
1 0 0 0 0 0 0
3
Busy tone 
detection
1: Yes
0: No
Yes
1 1 1 1 1 1 1
4
Dial tone 
monitoring time
1: 10sec
0: 5sec
5sec
0 0 0 0 0 0 0
5
Dial tone ON/OFF 
detection time 
upper limit 
(Intermittent 
detection)
1: 400ms
0: 700ms
700ms
0 0 0 0 0 0 0
6
Max. length of 
reception
1: No limit
0: 1.5m
1.5m
0 0 0 0 0 0 0
7
Destination 
display time when 
one-touch key is 
pressed
Bit No.
7
8
2sec
0 0 0 0 0 0 0
When a value outside 
the set range is set, 
the initial value is set.
2sec
0
0
8
4sec
0
1
0 0 0 0 0 0 0
6sec
1
0
S
W
8
1
Memory 
transmission/
direct transmission 
default setup
1: Direct transmission
0: Memory transmission
Memory 
transmission
0 0 0 0 0 0 0
2
Proxy  reception
1: Yes
0: No
Yes
1 1 1 1 1 1 1
3
Inhibited to use
0 0 0 0 0 0 0
4
Quick  online  send 1: Yes
0: No
Yes
1 1 1 1 1 1 1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
A B C D E F G
Page of 72
Display

Click on the first or last page to see other AR-FX13 service manuals if exist.