Sharp AR-FX13 Service Manual ▷ View online

AR-FX13  FAX SOFT SWITCH  5 - 20
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
S
W
89
1
Inhibited to use
0
2
0
3
1
4
1
5
1
6
1
7
1
8
1
S
W
90
1
Inhibited to use
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
S
W
91
1
Symbol speed 3429 send enable in 
V.34 send
1: Enable
0: Disable
Enable
1
2
Symbol speed 3200 high carrier 
send enable in V.34 send
1: Enable
0: Disable
Enable
1
3
Symbol speed 3200 low carrier 
send enable in V.34 send
1: Enable
0: Disable
Enable
1
4
Symbol speed 3000 high carrier 
send enable in V.34 send
1: Enable
0: Disable
Enable
1
5
Symbol speed 3000 low carrier 
send enable in V.34 send
1: Enable
0: Disable
Enable
1
6
Symbol speed 3429 enable in V.34 
communicate
1: Enable
0: Disable
Enable
1
7
Symbol speed 2800 enable in V.34 
communicate
1: Enable
0: Disable
Enable
1
8
Symbol speed 2743 enable in V.34 
communicate
1: Enable
0: Disable
Enable
1
S
W
92
1
Inhibited to use
0
2
1
3
0
4
1
5
1
6
0
7
0
8
0
S
W
93
1
Inhibited to use
0
2
1
3
0
4
1
5
1
6
0
7
0
8
0
S
W
94
1
Inhibited to use
0
2
1
3
0
4
1
5
1
6
0
7
0
8
0
AR-FX13  FAX SOFT SWITCH  5 - 21
S
W
95
1
Inhibited to use
0
2
1
3
1
4
1
5
0
6
0
7
0
8
0
S
W
96
1
Inhibited to use
1
2
1
3
0
4
1
5
1
6
0
7
0
8
0
S
W
97
1
Inhibited to use
0
2
1
3
1
4
1
5
1
6
1
7
1
8
1
S
W
98
1
Inhibited to use
0
2
1
3
0
4
0
5
0
6
0
7
0
8
0
S
W
99
1
Inhibited to use
0
2
1
3
0
4
1
5
1
6
0
7
0
8
0
S
W
100
1
Inhibited to use
1
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
101
1
Print effective image area sub scan 
lead edge void (Back surface)
Binary input
32 lines
0
2
Bit  No.
Set range
1
2
3
4
0 to 240 lines
16 lines interval (600dpi)
0
3
1
4
0
5
Print effective image area sub scan 
rear edge void (Back surface)
Binary input
48 lines
0
6
Bit  No.
Set range
5
6
7
8
0 to 240 lines
16 lines interval (600dpi)
0
7
1
8
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
AR-FX13  FAX SOFT SWITCH  5 - 22
S
W
102
1
Scan effective image area main 
scan left edge image loss (OC)
Binary input
96 dots
0
2
Bit  No.
Set range
1
2
3
4
0 to 360 dots
24 dots interval
1
3
0
4
0
5
Scan effective image area main 
scan right edge image loss (OC)
Binary input
96 dots
0
6
Bit  No.
Set range
5
6
7
8
0 to 360 dots
24 dots interval
1
7
0
8
0
S
W
103
1
Scan effective image area sub scan 
lead edge image loss (OC)
Binary input
96 lines
0
2
Bit  No.
Set range
1
2
3
4
0 to 240 line
16 lines interval
1
3
1
4
0
5
Scan effective image area sub scan 
rear edge image loss (OC)
Binary input
144 lines
1
6
Bit  No.
Set range
5
6
7
8
0 to 240 line
16 lines interval
0
7
0
8
1
S
W
104
1
Scan effective image area main 
scan left edge image loss (RSPF 
back surface)
Binary input
96 dots
0
2
Bit  No.
Set range
1
2
3
4
0 to 360 dots
in the interval of 24 dots
1
3
0
4
0
5
Scan effective image area main 
scan right edge image loss (RSPF 
back surface)
Binary input
96 dots
0
6
Bit  No.
Set range
5
6
7
8
0 to 360 dots
in the interval of 24 dots
1
7
0
8
0
S
W
105
1
Scan magnification ratio adjustment 
(OC main scan) flag
1: –
0: +
+
0
2
Scan magnification ratio adjustment 
(OC main scan)
Binary input
0%
0
3
Bit  No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
106
1
Scan magnification ratio adjustment 
(OC sub scan) flag
1: –
0: +
+
0
2
Scan magnification ratio adjustment 
(OC sub scan)
Binary input
0%
0
3
Bit  No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
107
1
Scan magnification ratio adjustment 
(RSPF back surface main scan) 
flag
1: –
0: +
+
0
2
Scan magnification ratio adjustment 
(RSPF back surface main scan)
Binary input
0%
0
3
Bit  No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
108
1
Scan magnification ratio adjustment 
(RSPF back surface sub scan) flag
1: –
0: +
+
0
2
Scan magnification ratio adjustment 
(RSPF back surface sub scan)
Binary input
0%
0
3
Bit  No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
AR-FX13  FAX SOFT SWITCH  5 - 23
3. Soft switch descriptions
SW1 No.1, No.2 Image quality priority selection
Used to select the image quality setting when pressing [Clear All]
key or during auto clear.
Default: 0 0 (Normal)
SW1 No.3 Inhibited to use
SW1 No.4 Auto/Manual default setup
Used to select Auto/Manual reception mode when turning on the
power.
Default: 0 (Automatic reception)
SW1 No.5 Send request protection
Used to set enable/disable of the confidential function (inhibit to
send to erroneous destinations) in send request communication
(remote send).
The confidential function is performed by collating the number regis-
tered in this machine and the number registered in the remote
machine.
Sender number 
↔ Send request allow number
Default: 0 (Protected)
SW1 No.6–No.8 Inhibited to use
SW2 No.1–No.4 Inhibited to use
SW2 No.5–No.8 Remote selection number setup
Used to set the number in binary input for remote switch receive
from external telephone.
However, "
∗" in the remote switch number (X∗∗) is fixed.
Default: 5
SW3 No.1–No.5 Density default setup
Used to set the density when pressing [Clear All] key or during auto
clear.
Default: 0 0 1 0 0 (Medium)
SW3 No.6 Inhibited to use
SW3 No.7, No.8 Size specification
Used to set the size specification (AB series, inch series).
Under setting of "Follow information from machine," when command
information from the machine is uncertain, set this item to AB series.
Default: 0 1 (Conforms to the machine information.)
SW4 No.1–No.4 Recall interval in communication error
Used to set the interval for recall when communication is cut off by
an error during memory send. (Including no response from the
remote machine.)
Setting is made in binary input.
When set to 0, resend is mad immediately after completion of com-
munication.
However, the time interval set by SW21 "Interval between comple-
tion of communication and the next call" is valid.
For the New Zealand models, tough it is set to 0, recall is performed
in an interval of 1min.
Default: 1min
SW4 No.5–No.8 Recall interval in busy
Used to set the interval for the next call when busy tone is detected
in communication.
Setting is made in binary input.
Default: 3min
SW5 No.1, No2 Inhibited to use
SW5 No.3, No.4 G3 send data accumulation wait time
Used to set wait time for accumulation of image data before sending
image data directly.
Default: 0 0 (6sec)
SW5 No.5–No.8 Pause time setup
Used to set pause time when registering dials.
Default: 2sec
SW6 No.1 ECM
Used to set YES/NO of error resend mode.
When, however, SW43-1 (V.34 mode function) is OFF or when
SW34-1 (V.34 mode function) is ON and send is made other than
SG3, ECM setting of "NO" is valid.
Since the ECM function is essential in V.34 mode and the remote
machine may perform checking, when SW43-1 (V.34 mode function)
is ON , this function is invalid in reception.
Default: 1 (Yes)
SW6 No.2 CED signal send
Used to set YES/NO of CED signal send.
This is valid only when SW52-7 (V.34 mode function) is OFF.
This is because ANSam signal send is necessary for V.34 mode.
When set to 1, CED signal send is performed.
When set to 0, CED signal send is not performed.
Default: 1 (Yes)
S
W
109
1
Print magnification ratio adjustment 
(Main scan back surface) flag
1: –
0: +
+
0
2
Print magnification ratio adjustment 
(Main scan back surface)
Binary input
0%
0
3
Bit  No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
110
1
Print magnification ratio adjustment 
(Sub scan back surface) flag
1: –
0: +
+
0
2
Print magnification ratio adjustment 
(Sub scan back surface)
Binary input
0%
0
3
Bit  No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
Page of 72
Display