AR-FX13  FAX SOFT SWITCH  5 - 24
SW6 No.3 CSI transmission
Used to set YES/NO of CSI signal send.
CSI signal includes the sender's number.
Default: 1 (Yes)
SW6 No.4 DIS reception confirmation in G3 send
Used to set YES/NO of DIS receive check in G3 mode send.
When set to 1, DIS receive twice is checked.
When set to 0, DIS once is checked when "NSF/DIS" is received;
and DIS twice is checked when NSF is not received.
Default: 0 (Once in NFS reception, 2 time in DIS reception)
SW6 No.5 Inhibited to use
SW6 No.6 EOL detection timer
Used to set detection timer of EOL (EndOfLine) in Phase C receive.
Default: 0 (13sec)
SW6 No.7 Countermeasure for echo in reception (CED 
tone send interval)
Used to set the interval from CED send to FSK signal send of DIS.
Default: 1 (500ms)
SW6 No.8 Countermeasure for echo in transmission 
(After reception of DIS, hold time up to signal send is 
set.)
Used to set the interval from DIS receive to DSC signal send.
Default: 0 (500ms)
SW7 No.1 Dial tone ON/OFF detection time lower limit 
(Intermittent detection)
Used to set the minimum required time for detection of dial tone
when the dial tone detection is set to "YES" and the kind of the dial
tone detection is set to "Continuous."
Default: 0 (100ms)
SW7 No.2 Dial tone detection
Used to set whether dial tone is detected or not when calling out.
When set to 1, dial tone is detected before calling out.
When set to 0, dial tone is not detected and dialing is made after a
certain time (3.5sec).
Default: 1 (Yes) (U.S.A.) / 0 (No) (Other than U.S.A.)
SW7 No.3 Busy tone detection
Used to set YES/NO of busy tone detection when calling out.
Default: 1 (Yes)
SW7 No.4 Dial tone monitoring time
Used to set the monitoring time when detecting dial tone.
Default: 0 (5sec)
SW7 No.5 Dial tone ON/OFF detection time upper limit 
(Intermittent detection)
Used to set the upper limit time for detection of dial tone when the
dial tone detection is set to "YES" and the kind of the dial tone detec-
tion is set to "Intermittent."
If a dial tone is detected for more than this upper limit time, it is not
considered as a dial tone.
Default: 0 (700ms)
SW7 No.6 Max. length of reception
Used to set max. length of reception for long document.
Default: 0 (1.5m)
SW7 No.7, No.8 Destination display time when one-
touch key is pressed
Used to set the time from displaying the destination to the next oper-
ation in one-touch dial or reduction dial.
Default: 0 0 (2sec)
SW8 No.1 Memory transmission/direct transmission 
default setup
Used to set whether memory send is ON or direct send is made
(OFF) in the memory mode when pressing [Clear All] key or auto
clear.
Default: 0 (Memory transmission)
SW8 No.2 Proxy reception
Used to set whether proxy reception is enabled or not.
When set to 0, under the following error status, auto receive is not
made in auto receive mode.
• Cover open
• Unit error (Toner, drum, developing-related errors)
• Recording paper JAM
• Document JAM
• Recording paper empty
When set to 1, proxy reception is allowed.
Default: 1 (Yes)
SW8 No.3 Inhibited to use
SW8 No.4 Quick online send
Used to set whether quick online send function is enabled or not.
When set to 0, send in memory mode ON is made in memory send.
When set to 1, send in memory mode ON is made in quick online
send.
Default: 1 (Yes)
SW8 No.5 Remote select function
Used to set whether remote select function is enabled or not.
Default: 1 (Yes)
SW8 No.6–No.8 Number of times of CNG detection
Used to set the number of times of CNG detection for judgment of
detection.
Default: 3 times
SW9 No.1 Print of total communication time and total 
pages
Used to set whether the total communication time and total pages
are printed on the communication report or not.
When set to 1, the total communication time and total pages are
printed on the communication report.
When set to 0, the total communication time and total pages are not
printed on the communication report.
Default: 1 (Yes)
SW9 No.2 Inhibited to use
SW9 No.3–No.8 Ringing volume pattern number
Used to set ringing volume pattern.
Default: 7 (North America) / 1 (Other than North America)
SW10 No.1 Measurement of communication time 
(image)
Used to set YES/NO of measurement of communication time in
phase C. It is the communication time in the latest phase C. (Unit:
msec)
Valid only in ECM communication.
Default: 1 (Yes)
SW10 No.2 Sender's telephone number registration
Used to set whether registered sender's telephone number can be
changed or not.
Default: 0 (Allow)
SW10 No.3–No.5 Inhibited to use
AR-FX13  FAX SOFT SWITCH  5 - 25
SW10 No.6 ECM byte/frame
Used to set the frame size of error correction mode to be notified to
the remote machine.
Default: 0 (256 [bytes/frame])
SW10 No.7, No.8 Inhibited to use
SW11 No.1–No.8 Inhibited to use
SW12 No.1–No.4 Call time setup in automatic 
transmission (T0 timer setup)
Used to set call time in automatic send.
Setting is made by binary input of N into "(5sec x N) + 30sec" in the
increment of 5sec.
Default: 45sec
SW12 No.5 Inhibited to use
SW12 No.6, No.7 CI detection
Used to set the detection frequency of CI signal (call signal).
Default: 0 0 (4 sine wave)
SW12 No.8 Inhibited to use
SW13 No.1, No.2 Inhibited to use
SW13 No.3, No.4 Ringing volume
Used to set the ringing volume when call-in.
Default: 1 0 (Medium)
SW13 No.5, No.6 Speaker volume in DTMF send
Used to set the volume of transmission and DTMF sound from the
speaker when SPEAKER key is pressed.
Default: 1 0 (Medium)
SW13 No.7, No.8 Inhibited to use
SW14 No.1–No.8 Inhibited to use
SW15 No.1 Busy tone detection time (Lower limit)
Used to set the lower limit of busy tone detection time (ON time).
Default: 0 (250ms)
SW15 No.2 Busy tone detection time (Upper limit)
Used to set the upper limit of busy tone detection time (ON time).
SW15 No.3 Busy tone detection time (Lower limit 2)
Used to set the lower limit 2 of busy tone detection time (ON time).
SW15 No.4–No.8 Signal send level
Used to set signal send level from MODEM.
Setting is made in binary input in the increment of 1dBm.
SW16 No.1–No.4 Modem speed (V.33 mode or less)
Used to set send start speed in communication other than V.34
mode.
In an area of poor communication conditions, it is recommended to
set communication speed to a lower level in advance.
Default: 1 0 0 0 (V.17 14.4kbps)
SW16 No.5, No.6 Modem speed in reception fixed
Used to set receive procedure start speed in a remote machine
other than V.34.
In setting of no fixing, the operations are the same as V.17-
14400BPS.
Default: 0 0 (No fixing)
SW16 No.7, No.8 Inhibited to use
SW17 No.1 Inhibited to use
SW17 No.2 MH fixed (Except for SG3)
Used to set whether coding capacity is fixed to MH or not in commu-
nication other than SG3.
Default: 0 (No)
SW17 No.3 ECM MMR mode (Except for SG3)
Used to set whether MMR coding capacity is allowed or not in com-
munication other than SG3.
Default: 1 (Yes)
SW17 No.4 ECM JBIG mode (Except for SG3)
Used to set whether JBIG coding capacity is allowed or not in com-
munication other than SG3.
Default: 1 (Yes)
SW17 No.5 Inhibited to use
SW17 No.6 MH fixed (in SG3)
Used to set whether coding capacity is fixed to MH or not in SG3
communication.
Default: 0 (No)
SW17 No.7 ECM MMR mode (in SG3)
Used to set whether MMR coding capacity is allowed or not in SG3
communication.
Default: 1 (Yes)
SW17 No.8 ECM JBIG mode (in SG3)
Used to set whether JBIG coding capacity is allowed or not in SG3
communication.
Default: 1 (Yes)
SW18 No.1–No.8 Inhibited to use
SW19 No.1–No.5 Inhibited to use
SW19 No.6 Recording table automatic print
Used to set whether communication report is automatically output-
ted or not when the number of send/receive items which have not
outputted yet on communication report reaches 50.
When set to 1, they are automatically outputted.
When set to 0, they are not outputted even the number of items
reaches 50.
Default: 0 (No)
SW19 No.7, No.8 Inhibited to use
SW20 No.1, No.2 Line sound monitor range
Used to set line sound monitor range when line sound monitor func-
tion is used.
Default: 0 0 (OFF)
SW20 No.3 Line monitor display
Used to set whether the communication speed and the receive level
are displayed on LCD or not.
Default: 0 (No)
SW20 No.4 Inhibited to use
SW20 No.5 Receivable memory capacity
Used to set the remained memory capacity for allowing call-in.
Default: 0 (128Kbyte)
SW20 No.6–No.8 Inhibited to use
SW21 No.1–No.8 Interval between completion of 
communication and the next call
Used to set the interval between completion of communication and
the next call.
Setting is made in binary input.
Default: 1sec (North America) / 6sec (Other than North America)
SW22 No.1–No.8 Inhibited to use
SW23 No.1–No.8 Inhibited to use
Default: 0 (750ms) (North America, Europe) / 
1 (650ms) (Australia, New Zealand)
Default: 0 (Follows SW15-1.) (North America) / 
1 (150ms) (Other than North America)
Default: –12dBm (North America, New Zealand) / 
–11dBm (Europe) / –9dBm (Australia)
AR-FX13  FAX SOFT SWITCH  5 - 26
SW24 No.1, No.2 Inhibited to use
SW24 No.3, No4 Specified number reception (ANTI 
JUNK FAX)
Used to set whether the FAX receive rejection function is made valid
or not for registered FAX numbers.
Default: 0 0 (Not set.)
SW24 No.5 Inhibited to use
SW24 No.6 Document output setup in reception
Used to set the document output procedure; whether all the received
documents are collectively outputted after completion of reception or
every page is outputted when it is received.
SW24 No.7 Inhibited to use
SW24 No.8 Automatic reduction print
Used to set whether automatic reduction print is performed or not so
that a document longer than the fixed size and smaller than the auto-
matic reduction line number setting is printed on fixed size paper.
Default: 1 (Allow)
SW25 No.1–No.4 Automatic reduction rate setup
Used to set automatic reduction rate when automatic reduction print
is valid.
Default: 10%
SW25 No.5, No.6 Transmission end sound tone
Used to set transmission end sound tone in transmission.
Default: 0 1 (1000Hz)
SW25 No.7, No.8 Reception end sound tone
Used to set reception end sound tone in reception.
Default: 0 1 (1000Hz)
SW26 No.1 Read completion sound
Used to set whether buzzer sound is made or not when scan is com-
pleted.
In manual send or when scan is completed in direct send, buzzer
sound is not made.
Default: 0 (1sec)
SW26 No.2 Inhibited to use
SW26 No.3, No.4 Speaker volume setup
Used to set speaker volume.
The following sounds are the targets of this setting.
• Alarm sound
• Send end sound
• Receive end sound
• Scan end sound
Default: 0 1 (Small)
SW26 No.5–No.8 Inhibited to use
SW27 No.1–No.6 Inhibited to use
SW27 No.7, No.8 Recording paper tray selection
Used to select the recording paper tray used by FAX.
Valid only when two cassettes are installed.
Default: 0 0 (AUTO)
SW28 No.1–No.8 Inhibited to use
SW29 No.1–No.4 Number of auto switch calls of manual 
reception 
 auto reception
Used to set the number of calls to switch to auto receive in manual
receive mode.
When set to 0, switch to auto receive is not made.
Default: 0 time
SW29 No.5–No.8 Setup of number of times of call rings
Used to set the number of calls before starting reception in auto
receive mode.
Setting is made in binary input.
Default: 2 times
SW30 No.1 Report output when canceling
Used to set whether the user cancel report is outputted or not when
send is canceled during document send.
Default: 0 (Not output)
SW30 No.2–No.4 Inhibited to use
SW30 No.5 Default data, sender print
Used to set whether sender information (registered in the sender
registration), sending date, and time are printed on the upper edge
of send document or not.
Default: 1 (ON)
SW30 No.6 Inhibited to use
SW30 No.7 Date/sender print position setup
Used to set whether date/sender information is printed inside the
document area or outside the document area.
Default: 0 (Outside of document)
SW30 No.8 Inhibited to use
SW31 No.1, No.2 Report output (in transmission)
Used to set whether communication report is outputted or not after
completion of sending (excluding sequential broadcast and sequen-
tial send request).
Default: 1 0 (Only when transmission is failed.)
SW31 No.3, No.4 Report output (In broadcast and 
sequential send request)
Used to set whether communication report is outputted or not after
completion of sending (sequential broadcast and sequential send
request).
Default: 0 1 (All print)
SW31 No.5, No.6 Report output (in reception)
Used to set whether communication report is outputted or not in
reception.
Default: 0 0 (Print inhibited)
SW31 No.7, No.8 Contents of send document are 
printed in memory send
Used to set whether part of send document is printed on the commu-
nication report or not in memory send.
Default: 1 0 (Only the address to which transmission is failed)
SW32 No.1–No.4 Distinctive ringing (North America, 
Australia, New Zealand)
Used to set the ringing pattern as FAX reception.
Default: 0 0 0 0 (OFF)
SW32 No.5 Inhibited to use
SW32 No.6 Index print setup
Used to set whether the index is printed when outputting received
document or not.
Default: 0 (Not print)
SW32 No.7, No.8 Inhibited to use
SW33 No.1 Page number print setup
Used to set whether the page number is added to the sender infor-
mation print or not.
Default: 1 (Yes)
SW33 No.2–No.7 Inhibited to use
Default: 0 (Output after reception of every page)  (North America) / 
1 (Collective output after completion of reception) (Other
than North America)
AR-FX13  FAX SOFT SWITCH  5 - 27
SW33 No.8 Reception data duplex print
Used to set whether duplex print of received data is made or not.
Default: 0 (No)
SW34 No.1, No.2 Flash send wait time (North America, 
U.K., Netherlands, Luxembourg, Belgium, France, 
Australia, New Zealand: Inhibited to use)
Used to set the time from off-hook to Flash send.
Default: 1 0 (1sec)
SW34 No.3, No.4 Inhibited to use
SW34 No.5–No.8 Signal send level Max.
Used to set the max. signal send level.
Default: –8dBm
SW35 No.1 Cover function default setup
Used to set whether cover is added as default or not.
When auto clear is made by pressing [Clear All] key, the machine
returns to this setting.
Default: 0 (No)
SW35 No.2 Inhibited to use
SW35 No.3, No.4 CI delete max. OFF time
Used to set the max. wait time between detection of CI signal pulse
(number of times) and detection of the next CI signal pulse.
If CIK signal pulse is not detected within this time, the number of
calls up to that time is cleared.
Default: 0 0 (5sec) (Other than Europe) / 0 1 (10sec) (Europe)
SW35 No.5–No.8 Answering machine call number 
setting
Used to set the number of calls to switch to auto receive when
answering telephone is not called in when the receive mode is set to
the answering telephone connection mode.
Setting is made in binary input.
SW36 No.1–No.8 CNG detection completion time
Used to set the time for completion of CNG signal/mute detection in
the answering telephone connection mode.
Count is made from the last call signal.
Setting is made in binary input.
Default: 45sec
SW37 No.1–No.8 Inhibited to use
SW38 No.1, No.2 Protocol monitor
Used to set whether communication protocol result is printed or not
after completion of communication.
Default: 0 0 (Not printed.)
SW38 No.3 Protocol monitor save
Used to set whether the protocol monitor of the last communication
is saved or not. When set to "Saved," the previous protocol monitor
can be printed with SIM66-21.
Default: 1 (Yes)
SW38 No.4 Inhibited to use
SW38 No.5, No.6 Flash send time (North America, U.K., 
Netherlands, Luxembourg, Belgium, France, Australia, 
New Zealand: Inhibited to use)
Used to set the Flash send time.
Default: 0 0 (90ms)
SW38 No.7 Transfer function
Used to set whether transfer function is enabled or not.
Default: 1 (Allow)
SW38 No.8 Inhibited to use
SW39 No.1–No.3 Inhibited to use
SW39 No.4–No.8 DTMF signal send time
Used to set DTMF signal send time.
Setting is made in binary input by the increment of 10ms.
Default: 110ms (Other than Europe) / 80ms (Europe)
SW40 No.1–No.8 Number of times of recall in error
Used to set the number of times of recall when a communication
error occurs.
Setting is made in binary input.
When set to 0, recall is not made.
Default: 1 times
SW41 No.1–No.8 Number of times of recall in busy
Used to set the number of times of recall when busy tone is detected
during transmission.
Setting is made in binary input.
When set to 0, recall is not made.
Default: 2 times
SW42 No.1 Direct send recall (North America only)
Used to set whether direct send recall wait is allowed or not.
Default: 0 (Allow)
SW42 No.2 FAX receive auto select by CNG detection
Used to set whether FAX receive auto select is enabled or not when
CNG signal is detected with external telephone used.
Default: 1 (Allow)
SW42 No.3 Auto receive select in answering telephone 
connection mode
Used to set whether auto receive select function in answering tele-
phone connection mode is enabled or not.
Default: 0 (Inhibit)
SW42 No.4–No.7 Inhibited to use
SW42 No.8 V.34 mode function in manual 
communication
Used to set whether V.34 mode is enabled or not in manual commu-
nication.
When, however, SW43-1 is set to "0: OFF," V.34 mode is disabled
even tough this switch is set to "1: ON."
Default: 1 (ON)
SW43 No.1 V.34 mode function
Used to set whether V.34 mode is enabled or not as a capacity of
own machine in send/receive.
Default: 1 (ON)
SW43 No.2, No.3 Inhibited to use
SW43 No.4–No.6 Symbol speed mask in V.34 receive
Used to set symbol speed mask in V.34 receive.
Default: 1 0 1 (3429)
SW43 No.7, No.8 Inhibited to use
SW44 No.1–No.4 V.34 primary channel send speed
Used to set send start speed in V.34 send.
Setting is made in binary input of N in "2400 (bps) x N" in the range
of 2400bps – 33600bps.
N is set in the range of 0 – 15. When set to 0, 2400bps; when set to
15, 33600bps.
When set to 2400bps, all of SW91 No. 1 – 8 must be set as "Dis-
able".
Default: 33600bps
Default: 5 times (North America) / 