AR-FX13  FAX SOFT SWITCH  5 - 28
SW44 No.5–No.8 V.34 primary channel receive speed
Used to set receive start speed in V.34 receive.
Setting is made in binary input of N in "2400 (bps) x N" in the range
of 2400bps – 33600bps.
N is set in the range of 0 – 15. When set to 0, 2400bps; when set to
15, 33600bps.
When set to 2400bps, all of SW43 No. 4 – 6 must changed to 2400.
Default: 33600bps
SW45 No.1 FAST mode
Used to set whether FAST function is enabled or not.
Default: 0 (No)
SW45 No.2, No.3 Sequence of year/month/day in LCD, 
report, and sender record
Used to set the sequence of year/month/day in LCD, report, and
sender record.
SW45 No.4 Time display format
Used to set time display format in LCD, report, and sender record.
SW45 No.5–No.8 Scan effective image area main scan 
right edge image loss (RSPF)
Used to set image loss of scan effective area.
Image loss on the right edge in RSPF main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default:  96 dots
SW46 No.1 Specification of print sequence in duplex 
print
Used to set the print sequence in duplex print of received data.
When set to 1, an odd-number page is printed after printing the next
even-number page. (214365...)
When set to 0, print is made in the ordinary reception order.
(123456...)
Default: 1 (Print order (214365...))
SW46 No.2 Specification of rotating direction duplex 
back surface print
Used to set whether the back surface is rotated 180 degrees in
duplex print or not.
When set to 1, the back surface is rotated 180 degrees and printed.
When set to 0, the back surface is not rotated and printed.
Default: 1 (180 degrees rotation)
SW46 No.3 Priority in the day of week
Used to set which is indicated first, day or day of week, when date
format is in the sequence of day, month, and year.
When set to 1, day of week is indicated first, and then day is indi-
cated.
When set to 0, day is indicated first, and then day of week is indi-
cated.
SW46 No.4 Center No. in FAST mode
Used to set which is set as FAST center number, Service-No or
Host-Tel-No.
Default: 0 (Service-No.)
SW46 No.5 Summer time
Used to set whether summer time function is enabled or not.
When set to 1, summer time function is enabled.
When set to 0, summer time function is disabled.
SW46 No.6–No.8 PBX setting (North America, U.K., 
Netherlands, Luxembourg, Belgium, Australia, New 
Zealand: Inhibited to use)
Used to set Connect/Not Connect to PBX and to set the external line
connection method when connected to PBX.
Default: 0 0 0 (Setting OFF)
SW47 No.1 Inhibited to use
SW47 No.2 External telephone connection
Used to set whether external telephone is used or not.
This switch must be set to YES in order to use external telephone.
Default: 1 (Yes)
SW47 No.3–No.8 Inhibited to use
SW48 No.1, No.2 Tone/Pulse default setup
Used to set the dial type.
Default: 1 0 (TONE)
SW48 No.3 Telephone line menu
Used to set whether tone/pulse setting is displayed on the menu or
not.
SW48 No.4 Inhibited to use
SW48 No.5–No.8 Scan effective image area main scan 
left edge image loss (RSPF)
Used to set image loss of scan effective area.
Image loss on the left edge in RSPF main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW49 No.1, No.2 Inhibited to use
SW49 No.3–No.8 Speaker sound volume pattern number 
in DTMF send
Used to set sound volume pattern in DTMF send.
Default: 1
SW50 No.1, No.2 Line monitor volume
Used to set on-hook monitor volume and line volume in FAX commu-
nication.
Default: 1 0 (Medium)
SW50 No.3–No.8 Line monitor volume pattern number
Used to set line monitor volume pattern.
Default: 16
SW51 No.1–No.5 DTMF send level (High group) setup
Used to set high-group send level in DTMF signal send.
Setting is made in binary input in the increment of 1.0dBm.
SW51 No.6 CED detection time
Used to set detection time of CED/ANSam signal for judgment of
detection.
Default: 1000ms
Default: 0 1 (Month/Day/Year) (North America) / 
1 0 (Day/Month/Year) (Other than North America)
Default: 1 (am/pm) (North America) / 
0 (24H) (Other than North America)
Default: 0 (No) (North America, U.K., Netherlands, Luxembourg, 
Belgium, Australia, New Zealand) / 
1 (Yes) (Germany, Sweden, Spain, Italy, Switzerland, 
Finland, Denmark, Norway, France)
Default: 0 (Inhibit) (North America) / 
1 (Allow) (Other than North America)
Default: 0 (Allow) (North America) / 
1 (Inhibit) (Other than North America)
Default: –6dBm (North America, Europe) / 
–5dBm (Australia, New Zealand)
AR-FX13  FAX SOFT SWITCH  5 - 29
SW51 No.7, No.8 Busy tone detection cycle
Used to set detection cycle of pulses of busy tone for detection of
busy tone.
Default: 0 0 (2puls)
SW52 No.1, No.2 Busy tone detection level
Used to set the mini. Detection level in busy tone detection.
Default: 0 0 (–43dB)
SW52 No.3 Inhibited to use
SW52 No.4 Super G3 disabled in the last call-out of 
recall in case of an error
Used to set whether Super G3 is disabled or not in the last call-out of
recall in case of a send error.
When, however, the number of recall in case of a send error is 0, this
function does not operate.
Default: 0 (Super G3 disabled)
SW52 No.5 Error process in RTN reception
Used to set whether RTN reception is judged as an error or not.
(Only in G3 mode)
When set to 1, RTN reception is not judged as an error.
When set to 0, RTN reception is judged as an error.
Default: 0 (Error)
SW52 No.6, No.7 Inhibited to use
SW52 No.8 V.34 control channel communication speed
Used to set control channel communication speed in V.34 mode.
If the remote machine does not make 2400bps enable, the speed is
always 1200bps.
Default: 0 (1200bps)
SW53 No.1–No.4 Maximum DTMF send level
Used to set the max. send level of DTMF signal.
Setting is made in binary input in the increment of 1.0dBm.
Default: 0dBm
SW53 No.5–No.8 DTMF send level (difference between 
high and low level)
Used to set DTMF signal send level in low group by the difference
from that in high group.
Setting is made in binary input in the increment of 0.5dBm.
SW54 No.1–No.4 Scan effective image area sub scan 
lead edge image loss (RSPF)
Used to set image loss in scan image area.
Image loss on the lead edge in RSPF sub scan direction can be
adjusted. When the set value is increased, image loss on the lead
edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 96 lines
SW54 No.5–No.8 Scan effective image area sub scan 
rear edge image loss (RSPF)
Used to set image loss in scan image area.
Image loss on the rear edge in RSPF sub scan direction can be
adjusted. When the set value is increased, image loss on the rear
edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 144 lines
SW55 No.1–No.7 CI signal OFF detection enable time
Used to set the min. OFF time for judgment of 1 pulse (1 call) of CI
(call-in signal).
If OFF time continues more than the set value, it is judged as 1
pulse.
Setting is made in binary input in the increment of 10ms.
Default: 1200ms (Other than New Zealand) / 1100ms (New Zealand)
SW55 No.8 Inhibited to use
SW56 No.1–No.3 CI signal ON detection enable time
Used to set the min. ON time for judgment of 1 pulse (1 call) of CI
(call-in signal).
If ON time continues more than the set value, it is judged as 1 pulse.
Setting is made in binary input in the increment of 10ms.
SW56 No.4 Inhibited to use
SW56 No.5, No.6 DT/BT detection frequency range
Used to set DT/BT detection frequency range.
SW56 No.7, No.8 Inhibited to use
SW57 No.1 Inhibited to use
SW57 No.2 Sharp machine mode
Used to set whether communication is made in Sharp machine
mode or not.
Default: 1 (ON)
SW57 No.3 Inhibited to use
SW57 No.4–No.8 Reception gain adjustment
Used to set reception gain correction.
Setting is made in binary input in the increment of 0.5dBm.
Default: 0.0dBm
SW58 No.1–No.4 Dual wait inhibit time after CFR send
Used to set dual wait inhibit time after CFR send.
Setting is made in binary input in the increment of 200ms.
Default: 1600ms
SW58 No.5–No.8 FSK signal settlement time in double 
wait
Used to set FSK signal settlement time in double (dual) wait.
Setting is made in binary input in the increment of 50ms.
Default: 550ms (7)
SW59 No.1, No.2 Inhibited to use
SW59 No.3, No.4 Reception SED ON level
Used to set reception SED ON level.
Default: 1 1 (–48dB)
SW59 No.5, No.6 Transmission cable amplitude 
equalizer
Used to set transmission cable amplitude equalizer.
SW59 No.7, No.8 Reception cable amplitude equalizer
Used to set reception cable amplitude equalizer.
Default: 0 0 (0dB)
Default: +2.0dBm (Other than New Zealand) / 
+1.5dBm (New Zealand)
Default: 155ms (North America, Europe) / 
195ms (Australia, New Zealand)
Default: 1 1 (245Hz–650Hz) (Other than New Zealand) / 
1 0 (360Hz–440Hz) (New Zealand)
Default: 0 0 (0dB) (North America, Europe) / 
0 1 (4dB) (Australia, New Zealand)
AR-FX13  FAX SOFT SWITCH  5 - 30
SW60 No.1–No.4 Scan effective image area sub scan 
lead edge image loss (RSPF back surface)
Used to set image loss in scan image area.
Image loss on the lead edge in RSPF bask surface sub scan direc-
tion can be adjusted. When the set value is increased, image loss on
the lead edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 96 lines
SW60 No.5–No.8 Scan effective image area sub scan 
rear edge image loss (RSPF back surface)
Used to set image loss in scan image area.
Image loss on the rear edge in RSPF bask surface sub scan direc-
tion can be adjusted. When the set value is increased, image loss on
the rear edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 144 lines
SW61 No.1–No.8 Inhibited to use
SW62 No.1–No.3 Inhibited to use
SW62 No.4, No.5 V.8 mode ANSam signal send time
Used to set ANSam/CED signal send time.
Default: 0 1 (4sec)
SW62 No.6–No.8 Inhibited to use
SW63 No.1–No.8 Inhibited to use
SW64 No.1–No.8 Inhibited to use
SW65 No.1–No.8 Inhibited to use
SW66 No.1–No.8 Inhibited to use
SW67 No.1–No.4 Make time (10PPS) setup
Used to set make time in dialing in 10PPS.
Setting is made in binary input in the increment of 1ms.
SW67 No.5–No.8 Inhibited to use
SW68 No.1, No.2 Line open delay time in dial test
Used to set time interval between end of dialing and opening the
line. Valid only in dial test of simulation.
Default: 0 0 (2sec)
SW68 No.3, No.4 Inhibited to use
SW68 No.5–No.8 T1 timer setup
Used to set time for connection of the line when the remote machine
does not respond in FAX communication.
The time of ITU-T standard is 35 ± 5sec.
Setting is made in binary input in the increment of 5sec.
Default: 40sec
SW69 No.1–No.8 Inhibited to use
SW70 No.1–No.3 Inhibited to use
SW70 No.4 Reception waiting time between frames
Used to set reception wait time between frames.
Default: 0 (3.4sec)
SW70 No.5, No.6 Preamble send time of 300bps
Used to set preamble send time of 300bps.
Default: 0 1 (1.0sec)
SW70 No.7, No.8 RCP send times
Used to set number of times of RCP frame send.
Default: 0 0 (3 times)
SW71 No.1–No.8 Inhibited to use
SW72 No.1 EYE-Q check
Used to set TCF check in TCF reception.
When set to 1, check is made only with EYE-Q value (EQM value).
Therefore, TCF check is loosely made. 
When set to 0, check is made with received data and EYE-Q value
(EQM value).
Default: 0 (0 reception & EYE-Q check)
SW72 No.2 ERR frame reception operation
Used to set operations when an image with an error frame is
received.
Default: 0 (Not continue process. (Error))
SW72 No.3, No.4 Waiting time for CED/ANSam send 
start
Used to set waiting time from when the line is connected and the
machine enters FAX receive state to when CED/ANSam signal is
send to the line.
Default: 0 0 (2.25sec)
SW72 No.5 RTC EOL send times
Used to set number of times of RTC EOL send.
Default: 1 (6 times)
SW72 No.6 Inhibited to use
SW72 No.7, No.8 CNG send start
Used to set CNG send time.
Default: 0 0 (0.5sec)
SW73 No.1–No.8 Inhibited to use
SW74 No.1–No.4 Print effective image area sub scan 
lead edge void
Used to set print image area void.
The void amount on the lead edge in the sub scan direction can be
adjusted. When the set value is increased, the void amount on the
lead edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 32 lines
SW74 No.5–No.8 Inhibited to use
SW75 No.1 Manual calibration setting when sending
Setting to execute the manual calibration or not when sending.
In case of an abnormal current waveform, the auto calibration fails
and the DTFM signal is deformed. This setting provides the counter-
measure against that problem.
Default: 0 (OFF)
SW75 No.2 Manual calibration setting when a signal 
arrives
Setting to execute the manual calibration or not when a signal
arrives.
In case of an abnormal current waveform, the auto calibration fails
and the transmission is affected. This setting provides the counter-
measure against that problem.
Default: 0 (OFF)
SW75 No.3, No.4 Communication end sound (Buzzer 
sound length) setting
Used to set the length of communication end buzzer sound in com-
munication.
Default: 0 0 (3sec)
Default: 40ms (North America) / 
33ms (U.K., Netherlands, Luxembourg, Belgium, France) / 
41ms (Germany, Sweden, Spain, Italy, Switzerland, 
Finland, Denmark, Norway) / 
31ms (Australia) / 34ms (New Zealand)
AR-FX13  FAX SOFT SWITCH  5 - 31
SW75 No.5–No.8 Print effective image area main scan 
void
Used to set void amount in print image area.
The void amount in the main scan direction can be adjusted. When
the set value is increased, the margins on the right and the left are
increased.
Setting is made in binary input in the increment of 16 dots.
Default: 48 dots
SW76 No.1 Scan magnification ratio adjustment 
(main scan) flag
Used to set the main scan magnification ratio in scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW76 No.2–No.8 Scan magnification ratio adjustment 
(RSPF main scan)
Used to set the main scan magnification ratio in RSPF scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW77 No.1 Scan magnification ratio adjustment 
(sub scan) flag
Used to set the sub scan magnification ratio in scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW77 No.2–No.8 Scan magnification ratio adjustment 
(RSPF sub scan)
Used to set the sub scan magnification ratio in RSPF scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW78 No.1 Print magnification ratio adjustment 
(main scan) flag
Used to set the main scan magnification ratio in print.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW78 No.2–No.8 Print magnification ratio adjustment 
(main scan)
Used to set the main scan magnification ratio in print.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW79 No.1 Print magnification ratio adjustment 
(sub scan) flag
Used to set the sub scan magnification ratio in print.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW79 No.2–No.8 Print magnification ratio adjustment 
(sub scan)
Used to set the sub scan magnification ratio in print.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW80 No.1–No.8 Destination information
Used to set country code.
SW81 No.1–No.8 Language information
Used to set language.
SW82 No.1–No.4 OC scan size default setting
Used to set OC scan default size.
SW82 No.5–No.8 Inhibited to use
SW83 No.1, No.2 Inhibited to use
SW83 No.3–No.8 Speaker sound volume setting pattern 
number
Used to set sound volume pattern of communication end and scan
end.
Default: 1
SW84 No.1–No.8 Inhibited to use
SW85 No.1–No.8 Inhibited to use
SW86 No.1–No.8 Inhibited to use
SW87 No.1–No.8 Inhibited to use
SW88 No.1–No.8 Inhibited to use
SW89 No.1–No.8 Inhibited to use
SW90 No.1–No.8 Inhibited to use
SW91 No.1 Symbol speed 3429 send enable in V.34 send
Used to set whether symbol speed of 3429Hz is allowed or not in
V.34 send.
Default: 1 (Enable)
SW91 No.2 Symbol speed 3200 high carrier send enable 
in V.34 send
Used to set whether use of high carrier is allowed or not when sym-
bol speed of 3200Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.3 Symbol speed 3200 low carrier send enable 
in V.34 send
Used to set whether use of low carrier is allowed or not when symbol
speed of 3200Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.4 Symbol speed 3000 high carrier send enable 
in V.34 send
Used to set whether use of high carrier is allowed or not when sym-
bol speed of 3000Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.5 Symbol speed 3000 low carrier send enable 
in V.34 send
Used to set whether use of low carrier is allowed or not when symbol
speed of 3000Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.6 Symbol speed 3429 enable in V.34 
communicate
Used to set whether use of 3429Hz is allowed or not as symbol
speed in V.34 communicate.
Default: 1 (Enable)
SW91 No.7 Symbol speed 2800 enable in V.34 
communicate
Used to set whether use of 2800Hz is allowed or not as symbol
speed in V.34 communicate.
Default: 1 (Enable)
Default: 0 0 0 1 (LETTER) (North America) / 
0 0 1 1 (A4) (Other than North America)
Page of 72