Sharp AR-FX13 Service Manual ▷ View online

AR-FX13  FAX SOFT SWITCH  5 - 32
SW91 No.8 Symbol speed 2743 enable in V.34 
communicate
Used to set whether use of 2743Hz is allowed or not as symbol
speed in V.34 communicate.
Default: 1 (Enable)
SW92 No.1–No.8 Inhibited to use
SW93 No.1–No.8 Inhibited to use
SW94 No.1–No.8 Inhibited to use
SW95 No.1–No.8 Inhibited to use
SW96 No.1–No.8 Inhibited to use
SW97 No.1–No.8 Inhibited to use
SW98 No.1–No.8 Inhibited to use
SW99 No.1–No.8 Inhibited to use
SW100 No.1–No.8 Inhibited to use
SW101 No.1–No.4 Print effective image area sub scan 
lead edge void (Back surface)
Used to set void amount in print image area.
Void amount on the lead edge in sub scan direction can be adjusted.
When the set value is increased, the margin on the lead edge is
increased.
Setting is made in binary input in the increment of 16 lines.
Default: 32 lines
SW101 No.5–No.8 Print effective image area sub scan 
rear edge void (Back surface)
Void amount on the rear edge in sub scan direction can be adjusted.
When the set value is increased, the margin on the read edge is
increased.
Setting is made in binary input in the increment of 16 lines.
Default: 48 lines
SW102 No.1–No.4 Scan effective image area main scan 
left edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the left edge in OC main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW102 No.5–No.8 Scan effective image area main scan 
right edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the right edge in OC main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW103 No.1–No.4 Scan effective image area sub scan 
lead edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the lead edge in OC sub scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 96 lines
SW103 No.5–No.8 Scan effective image area sub scan 
rear edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the rear edge in OC sub scan direction can be
adjusted. When the set value is increased, image loss is increased. 
Setting is made in binary input in the increment of 16 lines.
Default: 144 lines
SW104 No.1–No.4 Scan effective image area main scan 
left edge image loss (RSPF back surface)
Used to set image loss in scan image area.
Image loss in RSPF back surface main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW104 No.5–No.8 Scan effective image area main scan 
right edge image loss (RSPF back surface)
Used to set image loss in scan image area.
Image loss on the right edge in RSPF back surface main scan direc-
tion can be adjusted. When the set value is increased, image loss is
increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW105 No.1 Scan magnification ratio adjustment 
(OC main scan) flag
Used to set the main scan magnification ratio in OC scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW105 No.2–No.8 Scan magnification ratio adjustment 
(OC main scan)
Used to set the main scan magnification ratio in OC scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW106 No.1 Scan magnification ratio adjustment 
(OC sub scan) flag
Used to set the sub scan magnification ratio in OC scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW106 No.2–No.8 Scan magnification ratio adjustment 
(OC sub scan)
Used to set the sub scan magnification ratio in OC scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW107 No.1 Scan magnification ratio adjustment 
(RSPF back surface main scan) flag
Used to set the main scan magnification ratio in RSPF back surface
scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW107 No.2–No.8 Scan magnification ratio adjustment 
(RSPF back surface main scan)
Used to set the main scan magnification ratio in RSPF back surface
scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW108 No.1 Scan magnification ratio adjustment 
(RSPF back surface sub scan) flag
Used to set the sub scan magnification ratio in RSPF back surface
scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
AR-FX13  FAX SOFT SWITCH  5 - 33
SW108 No.2–No.8 Scan magnification ratio adjustment 
(RSPF back surface sub scan)
Used to set the sub scan magnification ratio in RSPF back surface
scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW109 No.1 Print magnification ratio adjustment 
(Main scan back surface) flag
Used to set the main scan magnification ratio in back surface print.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW109 No.2–No.8 Print magnification ratio adjustment 
(Main scan back surface)
Used to set the main scan magnification ratio in back surface print.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW110 No.1 Print magnification ratio adjustment 
(Sub scan back surface) flag
Used to set the sub scan magnification ratio in back surface print.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW110 No.2–No.8 Print magnification ratio adjustment 
(Sub scan back surface)
Used to set the sub scan magnification ratio in back surface print.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
AR-FX13  TROUBLE CODES  6 - 1
[6] TROUBLE CODES
1. Trouble codes
A. Trouble codes list
B. Details of trouble codes
2. Communication error codes
A. Error code identification
Communication error xx (xxxx)
(In print out, the communication error display is made. In FAX status
check, “NGxxxxxx” is displayed.
When transmission or reception is not executed normally due to dis-
tur-bance in protocol signals and image signals by the trouble in the
line, the code of 6 digits is displayed on the transmission result
check menu (reception result check menu).
Upper 2 digits of a communication error code: 00 – 58 (error code) is
displayed. (Communication result code)
Lower 4 digits of a communication error code: Error code1, Error
code 2
1) Refer to the communication result code.
2) Refer to error code 1.
3) Refer to error code 2.
(Error code 1 other than V.34 mode is “00”.)
<Communication result code>
Main 
code
Sub 
code
Details of trouble
F6
10
FAX board trouble
U1
03
FAX board battery error
Main 
code
Sub 
code
Details of trouble
F6
10
Content FAX board trouble
Detail
Communication trouble between MCU and 
FAX control PWB
Cause
FAX control PWB connector disconnection
Defective harness between FAX control PWB 
and MCU PWB
Motherboard connector pin breakage
FAX control PWB ROM error/Data error
IC on FAX PWB causes abnormality
Check 
and 
remedy
Check connector/harness of FAX control 
PWB and MCU PWB.
Check the grounding of the copier.
Check FAX control PWB ROM.
Replace the FAX PWB.
U1
03
Content FAX board battery error
Details
The SRAM backup battery voltage on FAX 
PWB falls.
Cause
The SRAM backup battery voltage on FAX 
PWB falls.
Check 
and 
remedy
Check voltage of the SRAM back up battery.
Replace the battery.
Error code 
(Communication 
result)
Communication 
report result 
column
Communication interruption 
content
0 – 31
For details of 0 – 
31, refer to the 
communication 
result code.
Depends on the 
communication 
disconnection position.
For 16 or later, V.34 mode 
communication.
33
Busy
The calling side cannot 
connect the line with the 
other party.
34
Cancel
An interruption command is 
made during transmission or 
reception.
A reservation is canceled.
An interruption command is 
entered with the interruption 
key.
35
Power OFF
Power OFF during 
transmission or reception
36
(Recording paper 
empty)
37
(Recording paper 
jam)
38
Reception 
memory over
Memory over during 
reception
39
(Discrepancy in 
the number of 
sheets)
40
(Interface not 
accepted)
41
Transmission 
length over
The length of transmission 
data of one page exceeds 
the range during 
transmission.
42
Reception length 
over
The length of reception data 
of one page exceeds the 
range during reception.
43
Communication 
(OK)
Communication enable 
before transmission
44
Document error
A document jam during 
direct transmission
45
(Image quality 
error)
46
No response 
from the other 
party
The FAX signal from the 
other party cannot detect 
within T1 time.
47
(Communication 
error)
48
OK
Communication normal end
49
No send request 
function on the 
other party
The other party has no send 
request function when 
receiving a send request.
The other party has no data 
to send.
50
Send request not 
accepted
DCN is received for DTC 
when sending a send 
request.
There is no data to send 
when sending a send 
request.
51
Send request 
enable number 
discrepancy
Discrepancy in the enable 
number when sending a 
send request.
Discrepancy in the system 
number when sending a 
send request.
52
No confidential 
function on the 
other party
The other party has no 
confidential function when 
sending a confidential 
message. (Including the 
other company’s machines)
Error code 
(Communication 
result)
Communication 
report result 
column
Communication interruption 
content
AR-FX13  TROUBLE CODES  6 - 2
<Communication result codes>
(Note) For error codes 16 – 31, V.34 mode communication.
<Error codes 1>
Error codes 1 are fixed to “00”.
<Error codes 2>
53
Confidential 
function not 
accepted
DCN is received for NSS 
when receiving a confidential 
message.
54
Confidential box 
No. NG
A confidential box number 
which is not registered is 
directed when receiving a 
confidential message.
55
No interface 
function on the 
other party
The other party has no 
interface function when 
sending an interface 
command.
56
Interface not 
accepted
DCN is received for NSS 
when sending an interface 
command.
A receiving station number 
which is not registered is 
directed when receiving an 
interface command.
57
Interface ID 
discrepancy
Discrepancy in the interface 
ID when receiving an 
interface command.
58
Reception 
inhibition number
Transmission is made from a 
reception inhibition number.
Error 
code
Final reception signal 
(Transmitting side)
Final reception signal 
(Receiving side)
0
Abnormal signal
Abnormal signal
1
NSF, DIS
NSS, DCS
2
CFR
NSC, DTC
3
FTT
EOP
4
MCF
EOM
5
PIP, PIN
MPS
6
RTN,  RTP
PRI-Q
7
No signal
DCN
8
PPR
PPS-EOP
9
PPS-EOM
10
PPS-MPS, PPS-NULL
11
RNR
RR
12
CTR
CTC
13
ERR
EOR-Q
14
PPS-PRI-Q
15
16
Abnormal signal
Abnormal signal
17
NSF, DIS
NSS, DCS
18
CFR
NSC, DTC
19
FTT
PPS-EOP
20
MCF
PPS-EOM
21
PIP, PIN
PPS-MPS, PPS-NULL
22
RTN, RTP
PRI-Q
23
No signal
DCN
24
PPR
25
RNR
RR
26
CTR
CTC
27
ERR
EOR-Q
28
PPS-PRI-Q
29
V.8 Phase-1
V.8 Phase-1
30
V.8 Phase-2
V.8 Phase-2
31
V.8 Phase-3
V.8 Phase-3
Error code 
(Communication 
result)
Communication 
report result 
column
Communication interruption 
content
Error 
codes 2
Content of communication interruption
Transmission/
Reception
01
Transmission length over
Transmission
02
EOL time over
Reception
03
Carrier detection time up
Reception
04
Polarity reversion detection (in phase C) Transmission/
Reception
05
8 min over (in phase C)
Transmission
06
Memory image decoding error
Reception
07
Memory image decoding error
Transmission
08
Time up between frames in phase C
Transmission/
Reception
10
Communication request NG
Reception
11
Polarity reversion detection
Reception
12
Invalid command reception
Reception
13
Time over (1min timer/6sec timer)
Reception
14
PUT error
Reception
15
Time out occurrence during shift from 
Primary to Control in V.34 mode
Reception
20
Polarity reversion detection
Transmission
21
Invalid command reception
Transmission
22
Fall back retry number over
Transmission
23
Resend over of retry number
Transmission
24
Time over (T5 timer)
Transmission
25
Time over (T5 timer) in V.34 mode
Transmission
26
Time out occurrence during shift from 
Primary to Control in V.34 mode
Transmission
30
Communication error due to 
communication abnormality between 
FAX_SUB and FAX_MAIN
Transmission/
Reception
Page of 72
Display