PN-K321 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 1 
 
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 
 
1.
 
OPERATING PROCEDURES     
                                                     
1 – 1. SERVICE MENU 1 
Used to display the model name, the manufacturing No., the 
  firmware version/checksum, and the usage time.
 
MODEL
 Model 
name 
S/N
 Serial 
number 
VER(MAIN1) 
Main firmware1 version 
VER(MAIN2) 
Main firmware2 version 
VER(SUB)
 
SUB firmware version 
TPC1 
Firmware1 version of the touch panel 
*K322B only 
TPC2 
Firmware2 version of the touch panel 
*K322B only 
USAGE TIME
 Usage 
time 
ADJUSTMENT 
CHECK
 
When the white balance setting is reset 
to the initial value after replacement of   
the PWB or the panel, "W/B" is   
displayed. 
1) Press [INPUT/RETURN] and [MENU/ENTER] on right side of 
the machine simultaneously (for 5 seconds or longer) or press 
MENU and move the cursor to “OTHER” and press [BRIGHT - 
()], [BRIGHT + ()], [BRIGHT - ()], [BRIGHT + ()]. After “F” 
is displayed on upper left corner of the screen, press [INPUT], 
[MENU], [INPUT], and [MENU] or [BRIGHT - ()], [VOL - ()], 
[BRIGHT + ()], and [VOL + ()]. 
SERVICE MENU1 appears.
 
<MEMO> 
*Immediately after turning on the power, "CALCULATING" is 
displayed for the checksum for a while, and the result is dipslayed. 
*"F" mark is displayed in red when the adjustment lock is set to 
other than "Not" and displayed in blue when the OSD display is 
set to "Not." For the other cases, it is displayed in green.   
(The red color of “F” mark takes priority.  )              
1 – 2. SERVICE MENU 2
 
 
AGING
 AGING. 
>Refer to page 4 - 3 "2. AGING". 
FACTORY 
RESET 
Used to reset the user adjustment   
values, the usage time, and the   
operation logs to the factory setting. 
>Refer to page 4 - 3    "3. FACTORY   
RESET". 
MODEL TYPE 
Used to select the destination.   
JP: Japanese model 
US: North American model 
CN: Chinese model 
EU: European model /
 
Australia 
EUH:Europe model(Not HDMI) 
HARDWARE 
CHECK 
Used to display the hardware   
detection result. 
Do not change ON/OFF of the   
detection. 
>Refer to page 4 - 4    "4.   
HARDWARE CHECK". 
WHITE 
BALANCE 
SETTING 
>Refer to page 4 - 13    "7. WHITE   
BALANCE SETTING PROCEDURES   
BY OSD” and page 4-16 ”
 
8. WHITE 
BALANCE SETTING TOOL 
OPERATING PROCEDURE”.   
FIRMWARE 
UPDATE 
Used to update firmware 
>Refer to page 5-1 "FIRMWARE   
UPDATE  
PROCEDURE" 
GAMMA 
SETTING 
The GAMMA is set. 
>Refer to page 4 - 18    "9. GAMMA   
SETTING PROCEDURES WITH THE   
OSD" and page 4-20 “10. GAMMA 
SETTING TOOL PROCEDURES.   
1) With "SERVICE MENU1" displayed, select "SERVICE2" with   
[VOL-()] button and press [MENU] button. 
 
 
 
 
 
 
 
 
2) Select setting item with [VOL+ ()] [VOL- ()] button. 
3) Adjust it with the [BRIGHT- ()] [BRIGHT+ ()] button.   
When the item with => mark press [ENTER] button and 
advances to the next screen.   
4) Press [INPUT/RETURN] button to terminate the operation. 
: ’13/Dec 
PN-K321 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 2 
 
1 – 3. SERVICE MENU 3 
 
MODEL NAME 
SETTING 
Used to set the model name. 
S/N SETTING 
Used to set the Serial No. 
USAGE TIME 
SETTING 
Used to set the usage time. 
SYSTEM LOG 
INITIALIZE 
Used to initialize the system log. 
TEMP LOG 
INITIALIZE 
Used to initialize the time log. 
SAVE LOG 
Save system log to USB memory 
SAVE/RESTORE 
SETTING VALUE 
Save user setting value to USB memory, 
or Restore the user setting saved to USB 
memory 
1) With "SERVICE MENU1" display. 
Select "SERVICE3" with [VOL- (
)] button and press  
[BRIGHT+ (
)] button. 
 
 
 
 
 
 
 
 
 
 
2) Select setting item with [VOL+ (
)] [VOL- ()] button. 
3) Press [ENTER] button and advances to the next screen. 
4) Press [INPUT/RETURN] button to terminate the operation.
PN-K321/K322B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 3 
 
2.
 
AGING                                                                               
 
1) Enter the "SERVICE MENU 2" mode.   
2) Select "AGING" with [VOL+ (
)][VOL- ()] buttons, and press [ENTER] button. 
3) Select "AGING1" or "AGING2" with [VOL+ (
)] [VOL- ()] buttons, and press [ENTER] button. The aging is started. 
AGING1: Every time when [BRIGHT+ (
)] button is pressed, the whole screen color is changed. 
 
 
AGING2: The whole screen color is changed every 2 sec. 
 
 
4) To terminate aging, turn off the main power source. 
<MEMO> 
Press the [MENU/ENTER] and the [INPUT/RETURN] button for about 5 seconds (the LED blinks, or the "F" mark is displayed in the upper 
left corner of screen.), or, press the [BRIGHT- (
)], [BRIGHT+ ()], [BRIGHT- ()] and [BRIGHT+ ()] buttons in sequence with pointing 
the cursor to the [Other] menu. AGING1 is directly executed by pressing [VOL- (
)], [VOL+ ()], [VOL- ()], and [VOL+ ()] buttons in 
sequence. 
*The power button of the machine cannot terminate aging.
PN-K321/K322B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 4 
 
3.
 
FACTORY RESET                                                                       
 
Resets the user adjustment value, USAGE TIME and the Operation log to the factory preset values. 
<CAUTION> 
*When resetting is made, the operation logs are also deleted. If necessary, save the operation logs before resetting.     
1) Display the SERVICE MENU 2. 
2) Select "FACTORY RESET" with [VOL+ (
)], [VOL- ()] button, and press [ENTER] button. 
3) Select "ON" with [BRIGHT- (
)], [BRIGHT+ ()] buttons, and press [ENTER] button. "RESETTING" is displayed. After completion of 
initialization, the unit is booted in the DisplayPort mode. 
4) Turn the main power switch off and then back on. 
<MEMO> 
ITEM RESET 
ITEMS 
FACTORY RESET 
Used to reset the user adjustment values, the usage time, and the operation logs to the factory setting. 
(It includes USAGE TIME, Operation log, and Error log) 
ALL RESET 
Used to reset the user adjustment values, the usage time, and the operation logs to the factory setting. 
(It excepts USAGE TIME, Operation log and Error log) 