Sharp PN-K321 (serv.man3) Service Manual ▷ View online
PN-K321 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 1
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
1.
1.
OPERATING PROCEDURES
1 – 1. SERVICE MENU 1
Used to display the model name, the manufacturing No., the
firmware version/checksum, and the usage time.
MODEL
Model
name
S/N
Serial
number
VER(MAIN1)
Main firmware1 version
VER(MAIN2)
Main firmware2 version
VER(SUB)
SUB firmware version
TPC1
Firmware1 version of the touch panel
*K322B only
*K322B only
TPC2
Firmware2 version of the touch panel
*K322B only
*K322B only
USAGE TIME
Usage
time
ADJUSTMENT
CHECK
When the white balance setting is reset
to the initial value after replacement of
the PWB or the panel, "W/B" is
displayed.
to the initial value after replacement of
the PWB or the panel, "W/B" is
displayed.
1) Press [INPUT/RETURN] and [MENU/ENTER] on right side of
the machine simultaneously (for 5 seconds or longer) or press
MENU and move the cursor to “OTHER” and press [BRIGHT -
()], [BRIGHT + ()], [BRIGHT - ()], [BRIGHT + ()]. After “F”
is displayed on upper left corner of the screen, press [INPUT],
[MENU], [INPUT], and [MENU] or [BRIGHT - ()], [VOL - ()],
[BRIGHT + ()], and [VOL + ()].
SERVICE MENU1 appears.
<MEMO>
*Immediately after turning on the power, "CALCULATING" is
displayed for the checksum for a while, and the result is dipslayed.
*"F" mark is displayed in red when the adjustment lock is set to
other than "Not" and displayed in blue when the OSD display is
set to "Not." For the other cases, it is displayed in green.
(The red color of “F” mark takes priority. )
1 – 2. SERVICE MENU 2
AGING
AGING.
>Refer to page 4 - 3 "2. AGING".
FACTORY
RESET
Used to reset the user adjustment
values, the usage time, and the
operation logs to the factory setting.
>Refer to page 4 - 3 "3. FACTORY
RESET".
values, the usage time, and the
operation logs to the factory setting.
>Refer to page 4 - 3 "3. FACTORY
RESET".
MODEL TYPE
Used to select the destination.
JP: Japanese model
US: North American model
CN: Chinese model
EU: European model /
JP: Japanese model
US: North American model
CN: Chinese model
EU: European model /
Australia
EUH:Europe model(Not HDMI)
HARDWARE
CHECK
Used to display the hardware
detection result.
Do not change ON/OFF of the
detection.
>Refer to page 4 - 4 "4.
HARDWARE CHECK".
detection result.
Do not change ON/OFF of the
detection.
>Refer to page 4 - 4 "4.
HARDWARE CHECK".
WHITE
BALANCE
SETTING
>Refer to page 4 - 13 "7. WHITE
BALANCE SETTING PROCEDURES
BY OSD” and page 4-16 ”
BALANCE SETTING PROCEDURES
BY OSD” and page 4-16 ”
8. WHITE
BALANCE SETTING TOOL
OPERATING PROCEDURE”.
OPERATING PROCEDURE”.
FIRMWARE
UPDATE
Used to update firmware
>Refer to page 5-1 "FIRMWARE
UPDATE
PROCEDURE"
>Refer to page 5-1 "FIRMWARE
UPDATE
PROCEDURE"
GAMMA
SETTING
The GAMMA is set.
>Refer to page 4 - 18 "9. GAMMA
SETTING PROCEDURES WITH THE
OSD" and page 4-20 “10. GAMMA
SETTING TOOL PROCEDURES.
>Refer to page 4 - 18 "9. GAMMA
SETTING PROCEDURES WITH THE
OSD" and page 4-20 “10. GAMMA
SETTING TOOL PROCEDURES.
1) With "SERVICE MENU1" displayed, select "SERVICE2" with
[VOL-()] button and press [MENU] button.
2) Select setting item with [VOL+ ()] [VOL- ()] button.
3) Adjust it with the [BRIGHT- ()] [BRIGHT+ ()] button.
When the item with => mark press [ENTER] button and
advances to the next screen.
4) Press [INPUT/RETURN] button to terminate the operation.
: ’13/Dec
PN-K321 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 2
1 – 3. SERVICE MENU 3
MODEL NAME
SETTING
Used to set the model name.
S/N SETTING
Used to set the Serial No.
USAGE TIME
SETTING
Used to set the usage time.
SYSTEM LOG
INITIALIZE
Used to initialize the system log.
TEMP LOG
INITIALIZE
Used to initialize the time log.
SAVE LOG
Save system log to USB memory
SAVE/RESTORE
SETTING VALUE
Save user setting value to USB memory,
or Restore the user setting saved to USB
memory
1) With "SERVICE MENU1" display.
Select "SERVICE3" with [VOL- (
)] button and press
[BRIGHT+ (
)] button.
2) Select setting item with [VOL+ (
)] [VOL- ()] button.
3) Press [ENTER] button and advances to the next screen.
4) Press [INPUT/RETURN] button to terminate the operation.
PN-K321/K322B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 3
2.
AGING
1) Enter the "SERVICE MENU 2" mode.
2) Select "AGING" with [VOL+ (
)][VOL- ()] buttons, and press [ENTER] button.
3) Select "AGING1" or "AGING2" with [VOL+ (
)] [VOL- ()] buttons, and press [ENTER] button. The aging is started.
AGING1: Every time when [BRIGHT+ (
)] button is pressed, the whole screen color is changed.
AGING2: The whole screen color is changed every 2 sec.
4) To terminate aging, turn off the main power source.
<MEMO>
Press the [MENU/ENTER] and the [INPUT/RETURN] button for about 5 seconds (the LED blinks, or the "F" mark is displayed in the upper
left corner of screen.), or, press the [BRIGHT- (
)], [BRIGHT+ ()], [BRIGHT- ()] and [BRIGHT+ ()] buttons in sequence with pointing
the cursor to the [Other] menu. AGING1 is directly executed by pressing [VOL- (
)], [VOL+ ()], [VOL- ()], and [VOL+ ()] buttons in
sequence.
*The power button of the machine cannot terminate aging.
PN-K321/K322B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 4
3.
FACTORY RESET
Resets the user adjustment value, USAGE TIME and the Operation log to the factory preset values.
<CAUTION>
*When resetting is made, the operation logs are also deleted. If necessary, save the operation logs before resetting.
1) Display the SERVICE MENU 2.
2) Select "FACTORY RESET" with [VOL+ (
)], [VOL- ()] button, and press [ENTER] button.
3) Select "ON" with [BRIGHT- (
)], [BRIGHT+ ()] buttons, and press [ENTER] button. "RESETTING" is displayed. After completion of
initialization, the unit is booted in the DisplayPort mode.
4) Turn the main power switch off and then back on.
<MEMO>
ITEM RESET
ITEMS
FACTORY RESET
Used to reset the user adjustment values, the usage time, and the operation logs to the factory setting.
(It includes USAGE TIME, Operation log, and Error log)
ALL RESET
Used to reset the user adjustment values, the usage time, and the operation logs to the factory setting.
(It excepts USAGE TIME, Operation log and Error log)
Click on the first or last page to see other PN-K321 (serv.man3) service manuals if exist.