DOWNLOAD Sharp UP-X300 (serv.man45) Service Manual ↓ Size: 3.62 MB | Pages: 73 in PDF or view online for FREE

Model
UP-X300 (serv.man45)
Pages
73
Size
3.62 MB
Type
PDF
Document
Service Manual
Brand
Device
EPOS / UP-X300 Service Manual
File
up-x300-sm45.pdf
Date

Sharp UP-X300 (serv.man45) Service Manual ▷ View online

UP-X300V
DIagnostics Specifications
3 – 3
(2) Target Sector Read Test
[Test condition setting]
• Test area setting
•  Retry number setting (0 ~ 4)
This setting sets the retry number in case of an error.
•  Error Stop/Continue/1 pass
In case of an error, selection is made whether interrupt is made or not.
Also used to select whether the test is executed or not by 1 pass.
[Test contents]
The sequential read test for every one track is executed in the range set
as above.
Completion of the read test in the set range is counted as 1 pass.
The operation of this test is as shown below:
(3) Sequential Write/Read & Compare Test
[Test condition setting]
Similar to the test (2) above. However, the cylinder set range is 01
0 79.
[Test contents]
The worst pattern data are written into each track in all the set range.
Then perform the read/verify check. When the write/read test in the set
range in the direction of 0
0 79 cylinder is completed, it is considered
as 1 pass.
The operation of this test is as shown below:
When writing data, the write data is different from those originally stored.
(Worst pattern data)
Word data: There are two kinds of data: B6DBh, 6DB6h.
(4) Target Sector Write/Read-Compare Test
[Test condition setting]
Similar to the test (2) above.. However, setting of the retry number is omitted.
[Test contents]
The write/read test in the set range is executed.
When the write/read test in the set range is completed, it is considered
as 1 pass.
The operation of this test is as shown below:
(5) Error table display
The error contents generated in procedures (1) ~ (4) are displayed for
each test item. The display items are test item, test condition, drive, cyl-
inder, head, sector, error contents, and hour/minute/second. The maxi-
mum number of display items is 50 for each test.
4-2-5. Test Display
(1) Floppy Disk Test menu display
On the above menu, use [
2 ] and [ 4 ] keys to select a test item. Press
[ENTER] key to execute the test. When [ESC] key is pressed, the dis-
play returns to the initial menu.
(2) Sequential read only test execution display
Select an item in each position indicated with "
"
(In the above display, the item surrounded by a 
 is selected and the
value surrounded by a 
is selected.)
When, in the above display, "Pass count" is counted up (when the test
point is counted from 00.0.01 to 79.1.10, Pass count is counted up by 1)
and all the error counters of all the error kinds are not counted up
(remaining at 00000), the test is OK.
During execution of the test, when [SPACE] key is pressed, the test is
interrupted. 
During interruption of the test, when [SPACE] key is pressed, the test is
resumed. 
During execution or interruption of the test, when [ESC] key is pressed,
the display returns to the menu of (1).
Cylinder
: The cylinder number to be checked is set in the
range of 00
0 79. 
Head
: The head number to be checked is set in the range
of 0
0 1.
Sector
: The sector number to be checked is set in the range
of 00
0 18 (9).
Re-calibration
Seek to the track
to be tested
Lead test
These procedures
are repeated.
becoming
Re-calibration
Read/verify test
in all the set rage
These procedures are repeated.
becoming
Write to all the
set range.
Re-calibration
Seek to the
track to be
tested
These procedures are repeated.
becoming
Date
write
Read/
verify
Floppy Disk Drive Diagnostics
Sequential read only test
Target Sector read test
Sequential write/read & Compare test
Target sector write/read & Compare test
Error table display
ENTER:Select
ESC:Exit
:FMove
Sequential read only test
Drive_A(1.44MB)test ? [  Yes  No]
Error Kinds                  Drive_A
Cylinder scope ?
Bad command             xxxxx
Drive_A [00     79] 00 - 79
Bad Address Mark       xxxxx
Sector count ?
Drive_A [1,3,9] =  9
Error stop ?
Recalibrate error          xxxxx
Pass count = xxxxx
Test Point=CC,H,SS
TIME HH:MM:SS
Retry Count ? [0     4] =  0
[error stop  continue  1 pass]
Test Start [ Yes   No]
Test mode :  Read    Test drive : Drive_A
ESC:Exit
SPACE:Stop or Start
Error details content
(Cylinder, head, celector)
(hour : minute : sound)
UP-X300V
DIagnostics Specifications
3 – 4
(3) Target Sector Read Test execution display
Select an item in each position indicated with "
"
(In the above display, the item surrounded by a 
 is selected and the
value surrounded by a 
 is selected.)
When, in the above display, "Pass count" is counted up and all the error
counters of all the error kinds are not counted up (remaining at 00000),
the test is OK.
Procedures to interrupt, resume, or terminate the test are similar to the
above (3). 
(4) Sequential Write/Read & Compare Test execution display
Similar to the above (3). The different points are as follows:
Cylinder scope  ?
Drive_A [01 - 79] items differ from those in (3). (Different points are indi-
cated with 
.)
Test mode: 
Different points from (3) are indicated with a rectangle.
(5) Target sector write/read & Compare test execution display
Similar to the above (3). The different points are as follows:
Test mode: 
Different points from (3) are indicated with a rectangle.
4-2-6. Error contents
(1) Sequential read only test
(2) Target sector read test
• 
Bad command
(A command is terminated abnormally. (Under BIOS CALL INT13H status))
• 
Bad address mark
(The address mark cannot be found. (Under BIOS CALL INT13H status))
• 
Write protect 1
(The disk is set to write-protect. (Under BIOS CALL INT13H status))
• 
Record not found
(The sector cannot be found. (Under BIOS CALL INT13H status))
• 
Diskette change
(The diskette was changed. (Under BIOS CALL INT13H status))
• 
Bad DMA boundary
(A DMA overrun occurs. (Under BIOS CALL INT13H status))
• 
Bad error
(An abnormality occurs in the CPU. (Under BIOS CALL INT13H status))
• 
Bad controller
(A trouble occurs in the controller. (Under BIOS CALL INT13H status))
• 
Seek error
(A trouble occurs in seek operation. (Under BIOS CALL INT13H status))
• 
Time out error
(Time out occurs or the drive is not ready. (Under BIOS CALL INT13H
status))
• 
Other error
(An error other than the above occurs. (Under BIOS CALL INT13H status))
• 
Recalibrate error
(An error occurs when recalibrate is executed.)
• 
DSK not ready
(There is no floppy disk in the FD drive or the floppy disk is not formatted.)
(3) Sequential write/read & compare test
(4) Target sector write/read & compare test
• Compare error
(When the write data differ from read data, this error occurs.)
4-3. IDE I/F & Hard Disk (Std & Opt)
4-3-1. Outline
This test is used to display information on the installed hard disk and the
option hard disk test and data in the hard disk.
The test items are as follows:
• Read test: Seek (sequential) test, read only (target cylinder, target
sector), dump test
•  Write test: Write verify (target cylinder, target sector), patch test
• Other test: Drive status display, controller check, smart function ON/
OFF, error information display
4-3-2. Required Tools to be used
UP-X500 series main unit diag execution media  x 1
4-3-3. Test items
The purposes of this test are as follows:
[Read mode test]
[Write mode test]
When data write
displayed.
When data compare 
When data write
displayed.
When data compare 
Error details content
(Cylinder, head, celector)
(hour : minute : sound)
Target sector read test
Error Kinds                  Drive_A
Bad command             xxxxx
Bad Address Mark       xxxxx
Recalibrate error         xxxxx
Test mode :  Read    Test drive : Drive_A
Pass count = xxxxx
Test Point=CC,H,SS
TIME HH:MM:SS
Test Start ? [ Yes   No]
Test drive ? [ Drive_A]
Cylinder scope ?
Drive_A (1.44MB)
Sector count ?
Error stop ?
Retry Count ? [0      4] =  0
[error stop  continue  1 pass]
[00     79] = 00
Head number ?
[01     18(MAX9)] =  01 - 09
[0     1] =  0
ESC:Exit
SPACE:Stop
Start
or
write
verify
write
verify
• Drive status display
• Sequential seek test
•  Seek & read test
• Read test
•  Target sector read test
•  HD dump test
• Current check test
• Smart ON/OFF
• Smart value display
•  Seek & write/read-verify test
• Write/read-verify test
•  Target sector write/read-verify test
• HD patch test
• Error table
UP-X300V
DIagnostics Specifications
3 – 5
4-3-4. Test items
[Read mode test]
(1) Drive status display
The following standard values of hard disk drive are displayed:
(2) Sequential seek test
[Test condition setting]
•  LBA range (0 ~ final cylinder)
The LBA range for test is set. 
• Retry count (0 ~ 4)
The number of retry in case of an error is set. 
• Error stop/Continue/1 pass
In case of an error, selection is made whether interrupt is made or not.
Also used to select whether the test is executed or not by 1 pass. 
•  Test start? (Yes/No)
Used to select whether the test is executed or not. 
[Test contents]
Sequential seek is executed in the LBA range set in the above proce-
dure. (In the sequence of 0 
3 Final cylinder). When the seek test of the
set range is completed, it is considered as 1 pass. When an error
occurs during the above test, retry is repeated by the set number of
retry. If an error still occurs after completion of retry by the set n umber
of retry, error logging is made to the HD and the DRAM.
When "Error stop" is set in the test condition setting, if an error occurs
during the above test, the error display is interrupted. To resume the
test, press [SPACE] key.
When "Continue" is set, if an error occurs, the operation is not inter-
rupted though the error display is made.
When "1 Pass" is set, a series of tests is executed only once. 
(3) Seek & read test
[Test conditions setting]
Similar to the above (2). The following setting must be additionally per-
formed. Sector count (0 ~ Final sector)
The number of sectors to be read for one operation. 
[Test contents]
Sequential read is executed for every sector in the LBA range set by the
above procedure. (In the direction of 3 ~ Final cylinder)
When the write/read test in the set range is completed, it is considered
as 1 pass.
Before execution of read, however, seek is made to the previous LBA
and the next LBA.
[Head movement]
When reading an LBA (N), the head moves as follows:
In procedures 2 and 1, read is executed.
When an error occurs during the above test, retry is repeated by the set
retry number. If an error still occurs after completion of retry by the set
retry number, error logging is made to the DRAM.
When "Error Stop" is set in the test condition setting, if an error occurs
in the above test execution, the error display is interrupted. To resume
the test, press [SPACE] key.
When "Continue" is set, if an error occurs, the operation is not inter-
rupted though the error display is made.
When "Pass" is set, a series of tests is executed only once. 
(4) Read test
[Test condition setting]
Similar to the above (3).
[Test contents]
Sequential read is executed for every sector in the LBA range set in the
above procedure. (In the direction of 0 
3 Final cylinder).
When the read test of the set range is completed, it is considered as 1
pass. When an error occurs during the above test, retry is repeated by
the set number of retry. If an error still occurs after completion of retry
by the set n umber of retry, error logging is made to the DRAM. 
When "Error stop" is set in the test condition setting, if an error occurs
during the above test, the error display is interrupted. To resume the
test, press [SPACE] key.
When "Continue" is set, if an error occurs, the operation is not inter-
rupted though the error display is made.
When "1 Pass" is set, a series of tests is executed only once. 
(5) Target sector read test
[Test condition setting]
•  LBA range (0 - Final cylinder)
The LBA range to be tested is set. 
•  Sector count (0 - Final cylinder)
The number of sectors to be tested is set. 
•  Retry count (0 - 4)
The number of retry in case of an error is set. 
•  Error stop/Continue/1 Pass
In case of an error, selection is made whether interrupt is made or not. 
Also used to select whether the test is executed or not by 1 pass. 
•  Test start? (Yes/No)
Selection is made whether the test is executed or not. 
[Test contents]
Read is executed for the area of the sector number in the LBA range set
in the above procedure.
When the read test is completed in the set area, it is considered as 1 Pass. 
When an error occurs during the above test, retry is repeated by the set
number of retry. If an error still occurs after completion of retry by the
set n umber of retry, error logging is made to the DRAM. 
When "Error stop" is set in the test condition setting, if an error occurs
during the above test, the error display is interrupted. To resume the
test, press [SPACE] key.
When "Continue" is set, if an error occurs, the operation is not inter-
rupted though the error display is made.
When "1 Pass" is set, a series of tests is executed only once. 
(6) HD dump test
[Test condition setting]
•  Logical block address (0 - Final LBA)
A certain LBA number to be displayed is set. 
[Test contents]
The sectors set in the above are displayed in the unit of 256byte.
Hex data and ASCII characters are displayed. 
By key operations, the following 256 byte data or the previous 256 byte
data can be sequentially displayed.
• Drive type
• Memory capacity
•  Number of cylinders
•  Number of heads
•  Number of sectors
•  Number of LBA
• Firmware version
N-1
N+1
N
1
2
3
4
Next
10
9
11
0LBA
Previous
LBA
LBA to be tested
Next LBA
Final LBA
UP-X300V
DIagnostics Specifications
3 – 6
(7) Controller check test
The diag command built in the hard disk is executed to check the hard
disk controller.
[Write mode test]
When the following test is executed, the HDD data will be destroyed. 
(8) Smart ON/OFF
Used to select ON/OFF of the smart function of the hard disk. 
(9) Smart value display
This function is used to display the list of the values saved in the hard
disk and backed up them to the diag media. This function is valid only
when the smart function is ON.
(10) Seek & write/read-verify test
[Test condition setting]
Similar to the test (3) above.
[Test contents]
The worst pattern data are written for every sector into the LBA range
set in the above sequentially.
Then read/verify check is executed for every track. 
The read/verify check is executed only once. 
(1 Pass text)
When writing data, write different data from those stored previously.
Before executing write/read, seek is made to the previous LBA or the
next LBA of the target LBA. 
(Head movement)
When reading an LBA (N), the head moves as follows. (The head arm
oscillates back and forth.)
In the direction of 0 
3 LBA
(Worst pattern data)
There are two types of word data: B6DBh, and 6DB6h.
When an error occurs during the above test, retry is repeated by the set
number of retry. If an error still occurs after completion of retry by the
set number of retry, error logging is made to the DRAM. 
When "Error stop" is set in the test condition setting, if an error occurs
during the above test, the error display is interrupted. To resume the
test, press [SPACE] key.
When "Continue" is set, if an error occurs, the operation is not inter-
rupted though the error display is made.
When "1 Pass" is set, a series of tests is executed only once.
(11) Write/read-verify test
[Test condition setting]
Similar to the above (9).
[Test contents]
The worst pattern data are written for every sector into the LBA range
set in the above sequentially.
Then read/verify check is executed for every track. 
The read/verify check is executed only once. 
(1 Pass text)
When writing data, write different data from those stored previously.
(Worst pattern data)
There are two types of word data: B6DBh, and 6B6Gh.
When an error occurs during the above test, retry is repeated by the set
number of retry. If an error still occurs after completion of retry by the
set n umber of retry, error logging is made to the DRAM. 
When "Error stop" is set in the test condition setting, if an error occurs
during the above test, the error display is interrupted. To resume the
test, press [SPACE] key.
When "Continue" is set, if an error occurs, the operation is not inter-
rupted though the error display is made.
When "1 Pass" is set, a series of tests is executed only once. 
(12) Target sector write/read-verify test
(Test condition setting)
Similar to the test (5) above.
[Test contents] 
The write/read/verify test is executed for the sector number in the LBA
range set in the above. 
When the write/read test in the set range is completed, it is considered as 1 Pass.
When an error occurs during the above test, retry is repeated by the set
number of retry. If an error still occurs after completion of retry by the
set n umber of retry, error logging is made to the DRAM. 
When "Error stop" is set in the test condition setting, if an error occurs
during the above test, the error display is interrupted. To resume the
test, press [SPACE] key.
When "Continue" is set, if an error occurs, the operation is not inter-
rupted though the error display is made.
When "1 Pass" is set, a series of tests is executed only once. 
(13) HD patch test (Utility)
[Test condition setting]
Similar to the test (6) above. However, the LBA range is set to 000 - Final LBA.
[Test contents]
The sectors set in the above are displayed in the unit of 256 byte.
Hex data and ASCII data are displayed. 
By key operations, the following 256 byte data or the previous 256 byte
data can be sequentially displayed. 
After converting data on the display, it is written into the selected set
position. 
(14) Error table display (Diag)
In case of an error in the previous tests (1) ~ (12), error information is
saved in the DRAM. This function is used to display the information.
If there is no information, OK or NO ERROR is displayed.
(15) Other supplementary note
Error information if recorded in the sequence of occurrence up to 44
items. No further error information is recorded.
In the direction of 0 a Final LBA, write is executed. 
In the direction of 0 a Final LBA, read/verify check is executed. 
In the direction of 0 a Final LBA, write is executed.
In the direction of 0 a Final LBA, read/verify check is executed. 
N-1
N+1
N
1
2
3
4
Next
0LBA
 Previous
LBA
 LBA to be tested
Next LBA
 Final LBA
N+1
N-1
N
1
2
3
4
Next
In the direction of 0 
1 LBA
0LBA
 Previous
LBA
 LBA to be tested
Next LBA
 Final LBA
In the direction of 0 a Final LBA, write is executed. 
In the direction of 0 a Final LBA, read/verify check is executed. 
In the direction of 0 a Final LBA, write is executed.
In the direction of 0 a Final LBA, read/verify check is executed. 
Page of 73
Display