44
Items to be programmed
TERMINAL#
Enter the terminal number (1-254, 0).
CHANNEL#
Enter the channel number (0-5).
PRINTER
Select the model of the remote printer.
ER-01PU (SHARP)
TM-T90 (EPSON)
TM-H6000R (EPSON)
TM-T88(3)/T88(4) (EPSON)
TM-U220/230 (EPSON)
AUTO CUTTER
Choose whether to disable or enable the auto cutter function.
NO:
Disables the auto cutter function.
YES: Enables the auto cutter function.
PRINT TYPE
Select the receipt type.
ADDITION: Addition receipt type
S/D:
Single/double receipt type
ADD.+S:
Addition + single receipt type
D ADD.:
Double addition receipt type
D ADD+S: Double (addition + single) receipt type
SECOND KP
Enter the second remote (kitchen) printer number (1-9, 0).
NAME
Enter the name of the remote printer (max.12 characters).
INITIAL FEED#
Enter the initial line feed for the remote printer (0 to 64 lines).
SORT RCPT. CUTTING
Choose whether to disable or enable the partial cut between each sort group.
NO:
Disables the partial cut function.
YES: Enables the partial cut function.
SEQUENTIAL PRINT
Choose whether to disable or enable the sequential print function.
NO:
Disables the sequential print function.
YES: Enables the sequential print function.
Please consult your authorized SHARP dealer for appropriate settings of each item.
NOTE
45
(2) Optional programming for the remote printer – master and satellite
With the following procedure, you can specify what items to be printed on the remote printer.
1. 
Enter the PGM2 mode from the mode selection window.
2. 
Select “2 SETTING” from the displayed menu.
The SETTING window will appear.
3. 
Select “10 OPTIONAL” from the displayed menu.
The OPTIONAL window will appear.
4. 
Select “5 PRINT SELECT2” from the displayed menu.
The PRINT SELECT2 window will appear.
5. 
Make appropriate settings for items to be printed on the remote printer and touch the [EXIT] key.
(See below for programming of individual items.)
The DATA NOT SAVED  SAVE IT? dialogue will appear.
6. 
Select  “1.SAVE.”
Items to be programmed
SEPARATOR LINE
NO:
Does not print the separator line on the remote printer.
YES: Prints the separator line on the remote printer.
FREE TEXT ON KP
NO:
Does not print the free text on the remote printer.
YES: Prints the free text on the remote printer.
ITEM CODE ON KP
NO:
Does not print the PLU/department code on the remote printer.
YES: Prints the PLU/department code on the remote printer.
PRICE ON KP
NO:
Does not print the price on the remote printer.
YES: Prints the price on the remote printer.
AMOUNT ON KP
NO:
Does not print the amount on the remote printer.
YES: Prints the amount on the remote printer.
GUEST# ON KP
NO:
Does not print the number of guests on the remote printer.
YES: Prints the number of guests on the remote printer.
QTY=1 ON KP
NO:
Does not print quantity data on the remote printer when the quantity is “1.”
YES: Prints quantity data on the remote printer even though the quantity is “1.”
UNIT PRICE PRINT
NO:
Does not print the unit price on the bill printer.
YES: Prints the unit price on the bill printer.
For settings of the rest of the programming items for PRINT SELECT2, see the UP-3500
Instruction Manual.
NOTE
46
Manager Work Station (MWS) is the system that enables inline data communication between UP-3500 POS
terminals in the IRC system and a host P.C. via LAN interface.
For the setup of the Manager Work Station, please be sure to consult your authorized SHARP dealer.
The function of Manager Work Station:
1) Downloading of POS terminal data
[Terminal 
PC]
2) Uploading of POS terminal data
[Terminal 
PC]
3) Remote Job Entry (RJE) function
[Terminal 
PC]
4) T-LOG function
[Terminal 
PC]
5) MAIL MESSAGE function
[Terminal 
PC]
6) Uploading of SD card data
[Terminal 
PC]
(1) Programming of the MWS terminal number
The terminal number of MWS can be specified by the following procedure:
1. 
Enter the PGM2 mode from the mode selection window.
2. 
Select “2 SETTING” from the displayed menu.
The SETTING window will appear.
3. 
Select “22 MWS CONFIG” from the displayed menu.
The MWS CONFIG window will appear.
4. 
Touch the “IP ADDRESS 4” line and enter a terminal number (1-254) for a MWS terminal, and then
touch the [EXIT] key.
The DATA NOT SAVED  SAVE IT? dialogue will appear.
• Entering a terminal number of the machine itself results in “ENTRY ERROR.”
5. 
Select “1.SAVE.”
A terminal number for a machine in MWS must be different from its terminal number for the IRC
system.
NOTE
9. Programming for the Manager Work Station (MWS) 
– master and satellite
47
(2) Programming of the time-out time
The time-out value for receiving the data can be specified by the following procedure:
1. 
Enter the PGM2 mode from the mode selection window.
2. 
Select “2 SETTING” from the displayed menu.
The SETTING window will appear.
3. 
Select “22 MWS CONFIG” from the displayed menu.
The MWS CONFIG window will appear.
4. 
Touch the “TIME OUT” line and enter a number (1-255 (sec)) for the time-out time, and then touch the
[EXIT] key.
The DATA NOT SAVED  SAVE IT? dialogue will appear.
• This value (time-out value) will depend upon the application. Please consult your authorized SHARP
dealer.
5. 
Select “1.SAVE.”
(3) Programming of the gateway number
The gateway number can be specified by the following procedure:
1. 
Enter the PGM2 mode from the mode selection window.
2. 
Select “2 SETTING” from the displayed menu.
The SETTING window will appear.
3. 
Select “22 MWS CONFIG” from the displayed menu.
The MWS CONFIG window will appear.
4. 
Touch the “G.W. ADDR. 4” line and enter a number (1-254) for gateway IP address 4, and then touch
the [ENTER] key.
• Entering a terminal number of the machine itself results in “ENTRY ERROR.”