59
The recovery declaration procedure is as follows:
1. 
Enter the PGM2 mode from the mode selection window.
2. 
Select “DECLARATION” and press the 
e
key.
The DECLARATION window will appear.
3. 
Select “RECOVER DECLARE” and press the 
e
key.
60
(2) When the back-up master recovers from a breakdown – Recovery
declaration at the master
Flow of a recovery declaration at the master
1) The recovery declaration operation is done at the master.
2) Each satellite stops sending updated GLU data (and clerk data*) to the master temporarily.
3) The master sends the updated GLU data (and clerk data*) files to the back-up master.
4) The master informs all satellites of the back-up master's recovery.
5) The satellites restart sending updated GLU data (and clerk data*) to the back-up master and the
IRC system returns to the normal state.
*Only for the centralized clerk file system
The recovery declaration procedure is the same as “(1) When the master recovers from a breakdown.”
2) Transmission stops 
     temporarily.
3) Updated data file
Satellite
4) Back-up master 
      recovery information
Back-up master
Master
 1) Recovery declaration
5) Restart of updated data transmission
61
5
Error Recovery
With the manual clear operation, you can clear various item memories when necessary. This operation
should be done only when the master or system breaks down.
(1) Manual clearing procedure
In case of trouble, you can compulsively clear item memories causing the trouble and restore your
system using the following procedure,
Clearing procedure
1. 
Enter the PGM2 mode from the mode selection window.
2. 
Select “DATA CLEAR” and press the 
e
key.
The DATA CLEAR window will appear.
3. 
Referring to the list on the next page, select the
corresponding item and press the 
e
key.
The above-mentioned manual clearing jobs should be performed at the advice of your
authorized SHARP dealer.
NOTE
1. Manual clear operation
62
(2) List of manual clearing items
Manual clearing of the clerk 
sign-on state
Manual clearing of the ‘GLU 
data in use’ state
Manual clearing of the 
GENERAL (dept. and 
transaction) data memory
Manual clearing of the hourly 
sales data memory
Manual clearing of the clerk 
sales data memory
Manual clearing of the cashier 
sales data memory
Manual clearing of the daily net 
sales data memory
Manual clearing of the T-LOG 
buffer
Manual clearing of the electronic 
journal data
M
M
M
M
M
M
M
M
M
-
-
S
S
S
S
S
S
S
Effective only for clerks who is in the 
sign-on state at the master. (*2)
This operation clears all GLU data 
that is currently in use.
Only for the clerk + cashier system.
For T-LOG polling, see page 19.
SIGN ON FLAG
GLU USED FLAG
TRANSACTION
HOURLY
CLERK
CASHIER
DAILY NET
T-LOG
E. JOURNAL
Master(M)
Satellite(S)
Item
Description
Terminal*1
Remarks
*
1
 ‘M’ denotes manual clearing functions available at the master while ‘S’ denotes manual clearing functions available at 
satellites.
*
2
 Clerk sales data for each satellite at which a clerk signs on is not collected by manual clearing of the sign-on state. 
Clerk sales data is collected only when sign-off operation is done correctly at satellites.
Page of 68