51
The LAN interface for the UP-800F/UP-810F POS enables the UP-800F/UP-810F to perform in-line
communications to a host P.C. through the connection to a Manager Work Station (MWS).
For the setup of the Manager Work Station, please be sure to consult your authorized SHARP dealer.
The function of Manager Work Station:
1) Downloading of the terminal data
[Terminal 
PC]
2) Uploading of the terminal data
[Terminal 
PC]
3) Remote Job Entry (RJE) function
[Terminal 
PC]
4) T-LOG function
[Terminal 
PC]
5) ELECTRONIC MAIL function
[Terminal 
PC]
(1) Programming of the MWS terminal number
The terminal number of MWS can be specified by the following procedure:
1. 
Enter the PGM2 mode from the mode selection window.
2. 
Select “SETTING” and press the 
e
key.
The SETTING window will appear.
3. 
Select “MWS CONFIG” and press the 
e
key.
The MWS CONFIG window will appear.
4. 
Move the cursor to the “IP ADDRESS 4” line.
Enter the terminal number (0-254) in the IP ADDRESS 4 line
of MWS and press the 
c
key.
• Entering a terminal number of the machine itself results in
“ENTRY ERROR”.
9. Programming for the Manager Work Station (MWS) 
– master and satellite
52
(2) Programming of the time-out time
The time-out value for receiving the data can be specified by the following procedure:
1. 
Enter the PGM2 mode from the mode selection window.
2. 
Select “SETTING” and press the 
e
key.
The SETTING window will appear.
3. 
Select “MWS CONFIG” and press the 
e
key.
The MWS CONFIG window will appear.
4. 
Move the cursor to the “TIME OUT” line.
Enter the time-out time (1-255 (sec)) and press the 
c
key.
• This value (time-out value) will depend upon the application.
Please consult your authorized SHARP dealer.
(3) Programming of the gateway number
The gateway number can be specified by the following procedure:
1. 
Enter the PGM2 mode from the mode selection window.
2. 
Select “SETTING” and press the 
e
key.
The SETTING window will appear.
3. 
Select “MWS CONFIG” and press the 
e
key.
The MWS CONFIG window will appear.
4. 
Move the cursor to the “G.W. ADDR. 4” line.
Enter the gateway number (0-254) and press the 
c
key.
• Entering a terminal number of the machine itself results in
“ENTRY ERROR”.
• Entering a same number as pre-entered number in the IP
ADDRESS4 line results in “ENTRY ERROR”.
53
1. 
Enter the PGM2 mode from the mode selection window.
2. 
Select “READING” and press the 
e
key.
The READING window will appear.
3. 
Select “MWS CONFIG” and press the 
e
key.
The OUTPUT TO window will appear.
4. 
Select “DISPLAY” or “REPORT PRINTER” and press the 
e
key.
PGM2
MWS PRESET
TERMINAL NO.
192.168.070.001
TIME OUT
007
GATEWAY NO.
192.168.070.000
Terminal No.
Time-out time (7 sec)
GATEWAY No.
Sample Print (master)
10. Reading the contents of the Manager Work Station
(MWS) programming – master and satellite
54
4
System Back-Up
The IRC system incorporates a back-up system.
One of the satellites can be designated to serve as a back-up master.
For the setup of a back-up master in your IRC system, please consult your authorized SHARP dealer.
When both the master and back-up master are in order, the system works in the following sequence:
1) Each satellite sends updated GLU data (and clerk data*) to the master.
2) The master receives the data and sends back an acknowledgment signal to the satellite.
3) The satellite sends the updated data to the back-up master.
4) The back-up master receives the data and sends back an acknowledgment signal to the satellite.
*Only for the centralized clerk file system
If the master breaks down, the back-up master serves as the master after a master declaration is made at
the back-up master. If the back-up master breaks down, updated data transmission to it can be stopped by
a master declaration at the master. When the master or back-up master recovers from the breakdown, it
resumes its function as the master or back-up master by the recovery declaring operation.
1) Updated data
3) Updated data
2) Acknowledgment signal
4) Acknowledgment signal
Satellite
Back-up master
Master
1. How the IRC back-up system works
Page of 68