INF-11
SECTION 1 SERVICE INFORMATION
<98/86SQ1>
3. 4. Network connection check  mode (NW Mode)
1. Display the CAT mode (Refer to 3.1.).
2.  The CAT mode menu appears on the screen. Select the [NW Mode] menu with [pq] buttons and press the [ENTER] button 
to enter the NW mode.
3. Press the [ENTER] button to start the network connection check. The check result will be displayed in a few seconds.
To exit the NW mode
Press the [RETURN] button to return to the CAT mode menu
-8
 
dB
-17
 
dB
Displays the result of [TEST]
 
• OK  
: There is a response of PING
 
• BSY  
: On test executing
 
• G_NG  
: No response of PING
 
• L_NG  
: A LINK state is not established
Displays the signal quality of 4-route (A,B,C,D) at 
DIGITAL LINK operation 
 
• Min  
: Minimum signal level
 
• Max  
: Maximum signal level
Software version of Valens IC(RX) 
Cable length (It is displayed only 
                     when the LINK status is DIGITAL LINK.)
Model name of connected DIGITAL LINK apparatus
Displays the connection status
 
• No link  
: No connection
 
• DIGITAL LINK : Operates as DIGITAL LINK
 
• Ethernet  
: Operate as Ethernet
Displays HDMI ON/OFF, HDCP status
 
• No HDMI   :  Can not be recognized as a HDMI signal
 
• HDMI on   : Not HDCP HDMI signal
 
• HDCP on   : HDCP HDMI signal
CAT Panel sys.8.2
IIC Mode
CD Mode
NW Mode
SD Mode
MS Mode
ID Mode
INF-12
SECTION 1 SERVICE INFORMATION
<98/86SQ1>
3. 5. Status display mode (SD Mode)
•  In the SD mode, internal temperature, cumulated used time and cumulated power-on times can be checked.
1. Display the CAT mode (Refer to 3.1.).
2.  The CAT mode menu appears on the screen. Select the [SD Mode] menu with [pq] buttons and press the [ENTER] button  
to enter the SD mode.
To exit the SD mode
Press the [RETURN] button to return to the CAT mode.
CAT Panel sys.8.2
IIC Mode
CD Mode
NW Mode
SD Mode
MS Mode
ID Mode
• 
Parameter 
 
WT  
  : Cumulated power-on times
 
PT   
  : Cumulated used time (hour)
• 
Condition   Internal temperature (ºC) 
 
SLOT-IF : Temperature of
                        the SLOT-IF module (ºC)
 
BL   
  : Back Light setting value
• G Sensor
  [X, Y, Z]
 
 
 
  Angle (Displays up to 90 degrees.)
 
 
 
  Acceleration sensor value
INF-13
SECTION 1 SERVICE INFORMATION
<98/86SQ1>
3.6. Market select setting mode (MS Mode)
n
 After replacing the A module, this market select setting must be done following to the procedure below.
1. Display the CAT mode (Refer to 3.1.).
2.  The CAT mode menu appears on the screen. Select the [MS Mode] menu with [pq] buttons and press the [MUTE] button 
for more than 3 seconds to enter the MS mode.
3.  Select desired destination number with [pq] buttons and press the [ENTER] button to set. The present destination number 
will be changed to the same number of new destination number. At this moment, new destination number will be applied 
and all the user setting value will be reset to the factory initial data according to the destination set.
4. The message "Please turn off the power" appears on the screen. Please to power cord removal and insertion.
5.  The Display will turn on and then the "Display Language Selection" menu will be displayed on the screen. Select your lan-
guage with the [pq] buttons and press the [ENTER] button to set.
New destination number
Present destination number
Number Model
Destination
0
TH-98/86SQ1J
Japan
3
TH-98/86SQ1W
North America
Europe, Asia, Oceania
18
TH-98/86SQ1C
China
31
-
For factory use
33
English
 
English (UK)
Deutsch
Français
Italiano
Español
ENGLISH (US)
Русский
 OSD language
CAT Panel sys.8.2
IIC Mode
CD Mode
NW Mode
SD Mode
MS Mode
ID Mode
INF-14
SECTION 1 SERVICE INFORMATION
<98/86SQ1>
4. Troubleshooting Guide
The failure symptom "Power off" or "No picture or No sound" is reported but it can not be confirmed in the service, use this 
function to confirm the failure status and narrow down the failure circuit.
4. 1. Self check of signal system
1. Display the CAT mode (Refer to 3.1.).
2.  The CAT mode menu appears on the screen. Select the [ID Mode] menu with [pq] buttons, and press and hold the 
[MUTE] button until the ID mode menu appears. (It takes a few seconds to display it.)
To exit the ID mode
 - Press the [RETURN] button to return to the CAT mode menu
n
 Treatment action
Items
IIC Device
Symptom
Action
A
IC1
HA0_MEM
Not memorized some settings below.
Items listed below in the SETUP menu.
(Display ID Setting/Timer Setting/Control Terminal Select)
Check or replace A module
IC1
H50_DLK
Cannot receive signals through the LAN or DIGITAL LINK.
IC2
H92_TEMP
Temperature sensor is not working normally.
IC2
H16C_ACC
"Auto" function on "Display orientation (Landscape/Portrait)" 
menu is not work normally.
IC5
HA0_MEN
LAN function is not working normally.
IC6
H64_RTC
Timer function is not working normally.
SUB IC1
H6E_FE
Video and Audio of Digital signal (HDMI 1/2, DVI-D, DisplayPort, 
SLOT) and Analog signal (PC) are abnormal.
Check or replace FE module
F
IC2
H40_FRC
Frame creation function is not working normally.
Check or replace FRC module
SLT IC4
H90_TEMP
Temperature sensor is not working normally.
Check or replace SLOT IF module
CAT Panel sys.8.2
IIC Mode
CD Mode
NW Mode
SD Mode
MS Mode
ID Mode