Panasonic KX-TGK310RUB / KX-TGK320RUB / KX-TGKA31RUB Service Manual ▷ View online
33
KX-TGK310SP/KX-TGK310JT/KX-TGK320JT/KX-TGK310FR/KX-TGK310RU/KX-TGK320RU/KX-TGK310NE//KX-TGK310GR/KX-TGKA31EX/KX-TGKA31RU
9.1.4.2.
Handset
Cross Reference:
Power Supply Circuit/Reset Circuit (P.11)
Check the RF part (P.34)
Check the RF part (P.34)
Note:
(*1) Refer to Handset (Main) (P.81).
(*2) Refer to Check Point (Handset) (H) (P.43).
(*2) Refer to Check Point (Handset) (H) (P.43).
Check around Power Supply Circuit/Reset Circuit .
Check BBIC (IC1)
Does Handset make link with Base Unit?
(Correct working unit)
(Correct working unit)
Check around X1 and adjust clock frequency.
(*2)
NO
NO
NO
NO
Is the voltage of "1.8V" about 1.8 V?
(*1)
YES
YES
YES
YES
Is the voltage of CP3V about 3.0 V?
(*1)
Does the RF clock (CKM) oscillate: 10.368 MHz
in Handset Test Mode?
in Handset Test Mode?
Handset is OK. Check Base Unit.
YES
OK
Check the RF part.
NO
NO
Adjust 1.8V voltage to 1.8 V.
Is the voltage of CP4V about 4.0V?
(*1)
(When LED is ON)
34
KX-TGK310SP/KX-TGK310JT/KX-TGK320JT/KX-TGK310FR/KX-TGK310RU/KX-TGK320RU/KX-TGK310NE//KX-TGK310GR/KX-TGKA31EX/KX-TGKA31RU
9.1.5.
Check the RF part
9.1.5.1.
Finding out the Defective part
After All the Checkings or Repairing
1. Re-register the checked handset to the checked base unit, and Regular HS to Regular BU.
Note:
(*1) HS: Handset
(*2) BU: Base Unit
(*2) BU: Base Unit
1. Prepare Regular HS(*1) and Regular BU(*2).
2. a. Re-register regular HS (Normal mode) to base unit (to be checked).
If this operation fails in some ways, the base unit is defective.
b. Re-register handset (to be checked) to regular BU (Normal mode).
If this operation fails in some ways, the handset is defective.
2. a. Re-register regular HS (Normal mode) to base unit (to be checked).
If this operation fails in some ways, the base unit is defective.
b. Re-register handset (to be checked) to regular BU (Normal mode).
If this operation fails in some ways, the handset is defective.
Base unit is defective
Handset is defective
START
Registration of
Regular HS to
base unit
Registration of
handset to
Regular BU
(other checkings)
Registration of handset to base unit
(checked ones)
Registration of Regular HS to Regular BU
Yes
No
No
Yes
35
KX-TGK310SP/KX-TGK310JT/KX-TGK320JT/KX-TGK310FR/KX-TGK310RU/KX-TGK320RU/KX-TGK310NE//KX-TGK310GR/KX-TGKA31EX/KX-TGKA31RU
9.1.5.2.
RF Check Flowchart
Each item (1 ~ 6) of RF Check Flowchart corresponds to Check Table for RF part (P.36).
Please refer to the each item.
Please refer to the each item.
Note:
(*1) Refer to Check Link (P.32).
Start
Link
confirmation
Normal
1
Control
signal
confirmation
X'tal
Frequency
confirmation
TX confirmation
RX confirmation
Range
confirmation
Normal
TEST RANGE Check.
Check BBIC interface parts.
(RF Block <->BBIC on BU/HS P.C.B)
(RF Block <->BBIC on BU/HS P.C.B)
Adjust X'tal Frequency. (*1)
Check TX Block.
Check RX Block.
GOOD
6
2
3
4
5
OK
OK
OK
OK
NG
NG
NG
NG
NG
NG
OK
OK
36
KX-TGK310SP/KX-TGK310JT/KX-TGK320JT/KX-TGK310FR/KX-TGK310RU/KX-TGK320RU/KX-TGK310NE//KX-TGK310GR/KX-TGKA31EX/KX-TGKA31RU
9.1.5.3.
Check Table for RF part
Note:
(*1) Adjustment Standard (Base Unit) (P.52)
(*2) Adjustment Standard (Handset) (P.55)
(*2) Adjustment Standard (Handset) (P.55)
No.
Item
BU (Base Unit) Check
HS (Handset) Check
1
Link Confirmation Normal
HS, BU Mode [Normal Mode]
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
2
X
'
tal Frequency confirmation
HS, BU Mode: [Adjustment]
Check X
'
tal Frequency.
(13.824000 MHz ±100 Hz)
Check X
'
tal Frequency.
(10.368000 MHz ±100 Hz)
3
TX confirmation
Regular HS (BU) Mode:
[Test RX Mode]
[Test RX Mode]
BU (HS) Mode:
[Test TX_Burst Mode]
[Test TX_Burst Mode]
1. Place Regular HS 15 cm away from a
checked BU.
2. Confirm "TXDATA" waveform of BU (*1)
and “RXDATA“ waveform of Regular HS by
Digital Oscilloscope.
Digital Oscilloscope.
1. Place Regular BU 15 cm away from a
checked HS.
2. Confirm "TXDATA" waveform of HS (*2)
and "RXDATA" waveform of Regular BU by
Digital Oscilloscope.
Digital Oscilloscope.
4
RX confirmation
Regular HS (BU) Mode:
[Test TX_Burst Mode]
[Test TX_Burst Mode]
BU (HS) Mode:
[Test RX Mode]
[Test RX Mode]
1. Place Regular HS 15 cm away from a
checked BU.
2. Confirm "RXDATA" waveform of BU (*1)
and “TXDATA“ waveform of Regular HS by
Digital Oscilloscope.
Digital Oscilloscope.
1. Place Regular BU 15 cm away from a
checked HS.
2. Confirm "RXDATA" waveform of HS (*2)
and "TXDATA" waveform of Regular BU by
Digital Oscilloscope.
Digital Oscilloscope.
5
Range Confirmation Normal
HS, BU Mode: [Normal Mode]
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
3. Compare the range of the BU (being
checked) with that of the Regular BU.
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
3. Compare the range of the HS (being
3. Compare the range of the HS (being
checked) with that of the Regular HS.
Click on the first or last page to see other KX-TGK310RUB / KX-TGK320RUB / KX-TGKA31RUB service manuals if exist.