Panasonic KX-TGK310RUB / KX-TGK320RUB / KX-TGKA31RUB Service Manual ▷ View online
21
KX-TGK310SP/KX-TGK310JT/KX-TGK320JT/KX-TGK310FR/KX-TGK310RU/KX-TGK320RU/KX-TGK310NE//KX-TGK310GR/KX-TGKA31EX/KX-TGKA31RU
8.1.1.2.
For RU
_ _ _ _ _ _
Set Addr.:
Default Data
Set Addr.:
C
New Data
Set Addr.:
C
Service Mode
Read EEP
Write EEP
Get S/W Ver.
OK
OK
OK
1
4
7
8
0
2
5
9
3
6
Important:
Make sure the address on LCD is correct when entering new data. Otherwise, you may ruin the unit.
9). Press to return to standby mode.
After that, turn the base unit power off and then power on.
2). Select "Initial Setup" using or
then press
{
OK
}
.
H/S key operation
{^}
4). Enter "7", "2", "6", "2", "7", "6", "6", "4".
Note: 7262 7664 = PANA SONI
(see letters printed on dial keys)
6). Enter " ", " ", " ", " " (Address). (*1)
7). Enter " ", " " (New Data). (*1)
5). Select "Write EEP" using or
then press
or
{>}
.
3). Select "Line Setup" using or
then press
{
OK
}
or
{>}
.
8). Press , a long confirmation beep
will be heard.
{
OK
}
{
OK
}
1). Press .
{
}
{V}
{^}
{V}
{^}
{V}
{ }(Off/Power)
H/S LCD
Soft keys
(Volume) key/
(Phonebook)/
(Caller list) key/
(Redial) key/
Navigator key/
Base Unit
{ }(Off/Power)
/ECO
{
}
R
R: Recall/Flash
ECO: Eco mode shortcut key
ECO: Eco mode shortcut key
(Talk)
{
}
Dial Keypad
22
KX-TGK310SP/KX-TGK310JT/KX-TGK320JT/KX-TGK310FR/KX-TGK310RU/KX-TGK320RU/KX-TGK310NE//KX-TGK310GR/KX-TGKA31EX/KX-TGKA31RU
Frequently Used Items (Base Unit)
Note:
*: When you enter the address, please refer to the table below.
ex.)
for SP / FR
(*1)
for JT
(*1)
for RU
Desired Number (hex)
Input Keys
Desired Number (hex)
Input Keys
0
0
A
Press and keep 1
1
1
B
Press and keep 2
.
.
C
Press and keep 3
.
.
D
Press and keep 4
.
.
E
Press and keep 5
9
9
F
Press and keep 6
Items
Address
Default Data
New Data
Remarks
Frequency
00 07 / 00 08
00/01
-
-
Use these items in a READ-ONLY mode to confirm
the contents. Careless rewriting may cause serious
damage to the computer system.
the contents. Careless rewriting may cause serious
damage to the computer system.
ID
00 02 ~ 00
06
Given value
-
-
Bell length
03 98
32 (5.0 sec)
(*1)
1E (3 sec)
14 (2 sec)
This is time until bell stops ringing. (Unit: 100 msec)
PULSE Dial speed
(10PPS -> 20PPS)
(10PPS -> 20PPS)
03 67
23 (33msec)
(*1)
00 C8 (20msec)
-
This is pulse make time. (Unit:0.1ms)
03 68
41 (67msec)
(*1)
01 2C (30msec)
-
This is pulse break time. (Unit:0.1ms)
03 87
57 (870msec)
(*1)
11 30 (440msec)
-
This is inter-digit time in pulse mode.
(Unit:0.1ms)
(Unit:0.1ms)
Bell length
32 (hex) = 50 (dec)
50 x 100 msec = 5000 msec (5.0 sec)
PULSE Dial speed
(10PPS -> 20PPS)
(10PPS -> 20PPS)
23 (hex) = 35 (dec)
(35-2) x 1 msec = 33 msec
41 (hex) = 65 (dec)
(65+2) x 1 msec = 67 msec
57 (hex) = 87 (dec)
87 x 10 msec = 870 msec
Items
Address
Default Data
New Data
Remarks
Frequency
00 07 / 00 08
00/01
-
-
Use these items in a READ-ONLY mode to confirm
the contents. Careless rewriting may cause serious
damage to the computer system.
the contents. Careless rewriting may cause serious
damage to the computer system.
ID
00 02 ~ 00
06
Given value
-
-
Bell length
03 98
32 (5.0 sec)
(*1)
1E (3 sec)
14 (2 sec)
This is time until bell stops ringing. (Unit: 100 msec)
PULSE Dial speed
(10PPS -> 20PPS)
(10PPS -> 20PPS)
03 67
2A (40msec)
(*1)
00 C8(20msec)
-
This is pulse make time. (Unit:0.1ms)
03 68
3A (60msec)
(*1)
01 2C(30msec)
-
This is pulse break time. (Unit:0.1ms)
03 87
57 (870msec)
(*1)
11 30(440msec)
-
This is inter-digit time in pulse mode.
(Unit:0.1ms)
(Unit:0.1ms)
Bell length
32 (hex) = 50 (dec)
50 x 100 msec = 5000 msec (5.0 sec)
PULSE Dial speed
(10PPS -> 20PPS)
(10PPS -> 20PPS)
2A (hex) = 42 (dec)
(42-2) x 1 msec = 40 msec
3A (hex) = 58 (dec)
(58+2) x 1 msec = 60 msec
57 (hex) = 87 (dec)
87 x 10 msec = 870 msec
Items
Address
Default Data
New Data
Remarks
C-ID (FSK) sensitivity
(for RU)
(for RU)
09 16/09 17
28/00
1C/00
(3 dB up)
14/00
(6 dB up)
When hex changes from “00/28” to “00/1C” or “00/
14”, gain increases by 3 dB or 6 dB.
14”, gain increases by 3 dB or 6 dB.
C-ID (DTMF) sensitivity
(for RU)
(for RU)
07 EF/07 F0
00/08
4C/0B
(3 dB up)
F6/0F
(6 dB up)
When hex changes from “08/00” to “0B/4C” or “0F/
F6”, gain increases by 3 dB or 6 dB.
F6”, gain increases by 3 dB or 6 dB.
Frequency
00 07 / 00 08
00/01
-
-
Use these items in a READ-ONLY mode to confirm
the contents. Careless rewriting may cause serious
damage to the computer system.
the contents. Careless rewriting may cause serious
damage to the computer system.
ID
00 02 ~ 00
06
Given value
-
-
Bell length
03 98
32 (5.0 sec)
(*1)
1E (3 sec)
14 (2 sec)
This is time until bell stops ringing. (Unit: 100 msec)
23
KX-TGK310SP/KX-TGK310JT/KX-TGK320JT/KX-TGK310FR/KX-TGK310RU/KX-TGK320RU/KX-TGK310NE//KX-TGK310GR/KX-TGKA31EX/KX-TGKA31RU
(*1)
for NE
(*1)
for GR
(*1)
PULSE Dial speed
(10PPS -> 20PPS)
(10PPS -> 20PPS)
03 67
28 (38msec)
(*1)
00 C8 (20msec)
-
This is pulse make time. (Unit:0.1ms)
03 68
3C (62msec)
(*1)
01 2C (30msec)
-
This is pulse break time. (Unit:0.1ms)
03 87
57 (870msec)
(*1)
11 30 (440msec)
-
This is inter-digit time in pulse mode.
(Unit:0.1ms)
(Unit:0.1ms)
Items
Address
Default Data
New Data
Remarks
Bell length
32 (hex) = 50 (dec)
50 x 100 msec = 5000 msec (5.0 sec)
PULSE Dial speed
(10PPS -> 20PPS)
(10PPS -> 20PPS)
28 (hex) = 40 (dec)
(40-2) x 1 msec = 38 msec
3C (hex) = 60 (dec)
(60+2) x 1 msec = 62 msec
57 (hex) = 87 (dec)
87 x 10 msec = 870 msec
Items
Address
Default Data
New Data
Remarks
SMS (FSK) receiving
sensitivity (for NE)
sensitivity (for NE)
09 16/09 17
28/00
1C/00
(3 dB up)
14/00
(6 dB up)
When hex changes from “00/28” to “00/1C” or “00/
14”, gain increases by 3 dB or 6 dB.
14”, gain increases by 3 dB or 6 dB.
SMS (FSK) sending
level (for NE)
level (for NE)
08 61/08 62
82/0C
4C/0B
(3 dB up)
F6/0F
(6 dB up)
When hex changes from “0C/82” to “0B/4C” or “0F/
F6”, gain increases by 3 dB or 6 dB.
F6”, gain increases by 3 dB or 6 dB.
Frequency
00 07 / 00 08
00/01
-
-
Use these items in a READ-ONLY mode to confirm
the contents. Careless rewriting may cause serious
damage to the computer system.
the contents. Careless rewriting may cause serious
damage to the computer system.
ID
00 02 ~ 00
06
Given value
-
-
Bell length
03 98
64 (10 sec)
(*1)
1E (3 sec)
14 (2 sec)
This is time until bell stops ringing. (Unit: 100 msec)
Bell length
64(hex) = 100 (dec)
100 x 100 msec = 10000 msec (10 sec)
Items
Address
Default Data
New Data
Remarks
SMS (FSK) receiving
sensitivity (for NE)
sensitivity (for NE)
09 16/09 17
28/00
1C/00
(3 dB up)
14/00
(6 dB up)
When hex changes from “00/28” to “00/1C” or “00/
14”, gain increases by 3 dB or 6 dB.
14”, gain increases by 3 dB or 6 dB.
SMS (FSK) sending
level (for NE)
level (for NE)
08 61/08 62
82/0C
4C/0B
(3 dB up)
F6/0F
(6 dB up)
When hex changes from “0C/82” to “0B/4C” or “0F/
F6”, gain increases by 3 dB or 6 dB.
F6”, gain increases by 3 dB or 6 dB.
Frequency
00 07 / 00 08
00/01
-
-
Use these items in a READ-ONLY mode to confirm
the contents. Careless rewriting may cause serious
damage to the computer system.
the contents. Careless rewriting may cause serious
damage to the computer system.
ID
00 02 ~ 00
06
Given value
-
-
Bell length
03 98
32 (5 sec)
(*1)
1E (3 sec)
14 (2 sec)
This is time until bell stops ringing. (Unit: 100 msec)
PULSE Dial speed
(10PPS -> 20PPS)
(10PPS -> 20PPS)
03 67
2A (40msec)
(*1)
00 C8(20msec)
-
This is pulse make time. (Unit:0.1ms)
03 68
3A (60msec)
(*1)
01 2C(30msec)
-
This is pulse break time. (Unit:0.1ms)
03 87
57 (870msec)
(*1)
11 30(440msec)
-
This is inter-digit time in pulse mode.
(Unit:0.1ms)
(Unit:0.1ms)
Bell length
32 (hex) = 50 (dec)
50 x 100 msec = 5000 msec (5.0 sec)
PULSE Dial speed
(10PPS -> 20PPS)
(10PPS -> 20PPS)
2A (hex) = 42 (dec)
(42-2) x 1 msec = 40 msec
3A (hex) = 58 (dec)
(58+2) x 1 msec = 60 msec
57 (hex) = 87 (dec)
87 x 10 msec = 870 msec
24
KX-TGK310SP/KX-TGK310JT/KX-TGK320JT/KX-TGK310FR/KX-TGK310RU/KX-TGK320RU/KX-TGK310NE//KX-TGK310GR/KX-TGKA31EX/KX-TGKA31RU
8.1.2.
Handset
8.1.2.1.
KX-TGKA31EX
_ _ _ _ _ _
Set Addr.:
Set Addr.:
Set Addr.:
Service Mode
Read EEP
Write EEP
Get S/W Ver.
C
C
OK
OK
OK
Important:
Make sure the address on LCD is correct when entering new data. Otherwise, you may ruin the unit.
9).
After that, turn the base unit power off and then power on.
2). Select "Initial Setup" using or
then press
{
OK
}
.
H/S key operation
{^}
3). Enter "7", "2", "6", "2", "7", "6", "6", "4".
Note: 7262 7664 = PANA SONI
(see letters printed on dial keys)
6). Enter " ", " ", " ", " " (Address). (*1)
7). Enter " ", " " (New Data). (*1)
4). Select "Write EEP" using or
then press
then press
or
{>}
.
H/S LCD
Default Data
New Data
8). Press , a long confirmation beep
will be heard.
{
OK
}
{
OK
}
1). Press .
{
}
{V}
{^}
{V}
Soft keys
(Volume) key/
(Phonebook)/
(Caller list) key/
(Redial) key/
Navigator key/
{ }(Off/Power)
/ECO
{
}
R
R: Recall/Flash
ECO: Eco mode shortcut key
ECO: Eco mode shortcut key
(Talk)
Dial Keypad
{
}
Press to return to standby mode.
{ }(Off/Power)
Click on the first or last page to see other KX-TGK310RUB / KX-TGK320RUB / KX-TGKA31RUB service manuals if exist.