PREFACE
<VW360/VX430/VX431K>
Operating environment
Operating environment temperature *
3
0 °C (32 °F) to 40 °C (104 °F) 
(Elevation: below 1 400 m (4 593'); [HIGH ALTITUDE MODE]: [OFF])
0 °C (32 °F) to 30 °C (86 °F)
(Elevation: 1 400 m (4 593') ~ 2 000 m (6 562′); [HIGH ALTITUDE MODE]: [HIGH1])
0 °C (32 °F) to 30 °C (86 °F)
(Elevation: 2 000 m (6 562′) ~ 2 700 m (8 858′); [HIGH ALTITUDE MODE]: [HIGH2])
Operating environment humidity: 
20% to 80% (no condensation)
Remote 
control
Power supply
DC 3 V (battery (AAA/R03 or AAA/LR03 Type ) x 2)
Operating range Approx. 7 m (22'11-5/8") (when operated directly in front of receptor)
Weight
63 g (2.22 ozs.) (including batteries)
Dimensions
Width : 44 mm (1-23/32"), Length : 105 mm (4-1/8"), Height : 20.5 mm (13/16")
*1  Measurement, measuring conditions and method of notation all comply with ISO/IEC 21118:2012 international standards.
*2  This is an average value. It may differ depending on individual product.
*3  If the [PROJECTOR SETUP] menu → [LAMP POWER] is set to [NORMAL], [LAMP POWER] will be switched to [ECO] forcibly to protect 
the projector when the operating environment temperature becomes 35 °C (95 °F) or higher.
Note
 
f
The part numbers of accessories and separately sold components are subject to change without notice.
 
r
Terminal
<COMPUTER 1 IN> terminal
1 set high-density D-Sub 15 p (female)
RGB signal
0.7 V [p-p] 75 Ω (When G-SYNC: 1.0 V [p-p] 75 Ω)
SYNC/HD
TTL high impedance, automatic positive/negative 
polarity compatible
VD
TTL high impedance, automatic positive/negative 
polarity compatible
(The SYNC/HD and VD terminals do not support 3 value SYNC.)
YP
B
P
R
 signal
Y: 1.0 V [p-p] including synchronization signal, P
B
P
: 0.7 V [p-p] 75 Ω
Y/C signal
Y: 1.0 V [p-p], C: 0.286 V [p-p] 75 Ω
<COMPUTER 2 IN /1 OUT> 
terminal
1 set, high-density D-Sub 15 p (female)
RGB signal
0.7 V [p-p] 75 Ω (When G-SYNC: 1.0 V [p-p] 75 Ω)
SYNC/HD
TTL high impedance, automatic positive/negative 
polarity compatible
VD
TTL high impedance, automatic positive/negative
polarity compatible
(The SYNC/HD and VD terminals do not support 3 value SYNC.)
YP
B
P
R
 signal
Y: 1.0 V [p-p] including synchronization signal, P
B
P
R
: 0.7 V [p-p] 75 Ω
<VIDEO IN> terminal
1 set, pin jack 1.0 V [p-p] 75 Ω
<HDMI 1 IN>/<HDMI 2 IN> 
terminal
2 sets, HDMI 19 pin, HDCP compatible, Deep Color compatible
Audio signal
Linear PCM (Sampling frequency: 48 kHz/44.1 kHz/32 kHz)
<AUDIO IN 1>/<AUDIO IN 2>
terminal
2 sets, M3 stereo mini jack 0.5 V [rms], input impedance 22 kΩ or more
<AUDIO IN 3> terminal
1 set, pin jack x 2 (L-R) 0.5 V [rms], input impedance 22 kΩ or more
<VARIABLE AUDIO OUT> 
terminal
1 set, M3 stereo mini jack (monitor output, stereo compatible)
0 V [rms] to 2.0 V [rms] (variable), output impedance 2.2 kΩ or less
<USB A (VIEWER/
WIRELESS)> terminal
1 set, USB connector (type A)
Memory Viewer / Wireless module (Model No.: ET-WML100) compatible
<USB B (DISPLAY)> terminal
1 set, USB connector (type B), only for USB display function
<SERIAL IN> terminal
1 set, D-Sub 9 p, RS-232C compliant, for computer control
<LAN> terminal
1 set, RJ-45, for network connection, PJLink (Class 1) compatible, 10Base-T/100Base-TX
ENGLISH - 131
Chapter 7  Appendix - Specifications
9
PREFACE
<VW360/VX430/VX431K>
 
r
Wireless LAN
To use the wireless LAN function with the projector, it is necessary to attach the optional Wireless Module (Model 
No.: ET-WML100).
Compliance standards
IEEE802.11a/b/g/n
Transmission method
DSSS, OFDM
Frequency range
(Channel)
2 412 MHz to 2 462 MHz (1 to 11 ch)
Transmission speed
(Standard value)
IEEE802.11b
Maximum 11 Mbps
IEEE802.11g
Maximum 54 Mbps
IEEE802.11n
Maximum 150 Mbps
Encryption method
WPA2-PSK(AES)
 
r
Compatible signals
Refer to “List of compatible signals” of Operting Instructions
 
 
 for the types of video signals that can be used with the 
projector.
For video signal input
Horizontal : 15.73 kHz Vertical : 59.94 Hz
Horizontal : 15.63 kHz Vertical : 50 Hz
For Y/C signal input
Horizontal : 15.73 kHz Vertical : 59.94 Hz
Horizontal : 15.63 kHz Vertical : 50 Hz
For RGB signal input
 
f
Displayable resolution: 640 x 400 to 1 920 x 1 200
 
f
Dot clock frequency: 162 MHz or less
For YC
B
C
R
/YP
B
P
R
 signal input
 
f
Displayable resolution: 480i/576i to 1 920 x 1 080
 
f
Dot clock frequency: 148.5 MHz or less
For HDMI signal input
 
f
Displayable resolution for movie-based signals: 480i/576i
*1
 to 1 920 x 1 080 
Displayable resolution for still image signals: 640 x 400 to 1 920 x 1 200 (non-interlaced)
 
f
Dot clock frequency: 25 MHz - 162 MHz
*1  Pixel-Repetition signal (dot clock frequency 27.0 MHz) only
132 - ENGLISH
10
PREFACE
<VW360/VX430/VX431K>
3. Dimensions
Dimensions
<Unit : mm (inch)>
113  (4-7/16")
255  (10-1/32")
352  (13-27/32")
24  (15/16")
98  (3-27/32")
90  (3-17/32")
326  (12-27/32")
198  (7-25/32")
59  (2-5/16")
 
Actual dimension may differ by product.
ENGLISH - 133
Chapter 7  Appendix - Dimensions
SECTION
1
INF-1
 (2018-06)
CONTENTS
1. The name of each part . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-2
1. 1. Remote controls
1. 2. Projector body 
1. 3. Control panel
1. 4. Connecting terminals
2. Menu Navigation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-6
2. 1. On-screen
3. Service Mode  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-10
3. 1. Setting to Service Mode
3. 2. Resetting to User Mode
3. 3. Functions of Service Mode
4. Notes on service  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-13
4. 1. Before service operation
4. 2. Service
4. 3. Note on the parts replacement work
4. 4. Replacement of consumable parts
4. 5. Security password
5. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-20
5. 1. LAMP/WARNING indicators
5. 2. Shutdown system
5. 3. Execution procedure of Self-diagnosis
5. 4. Lamp log data acquisition method
5. 5. Troubleshooting