Panasonic PT-RCQ10 / PT-RCQ80 (serv.man3) Service Manual ▷ View online
INF-13
SECTION 1 SERVICE INFORMATION
< RCQ10 / RCQ80 >
1. DYNAMIC GAMMA MODE
• Setting of the DYNAMIC GAMMA circuit operation.
- ON : Enable the Dynamic gamma function. (Default setting)
- OFF : Disable the Dynamic gamma function.
2. 3DCMS
• Setting of the 3D Color Management System circuit operation.
- ON : Enable the 3D Color Management system function. (Default setting)
- OFF : Disable the 3D Color Management system function.
3. SELF CHECK
• Self-diagnosing information Displays.
① --- Model number
② --- Serial number
------------ Firmware version ------------
③ --- Main microprocessor
④ --- Sub microprocessor
⑤ --- FPGA (FPGA2/FPGA3)
⑥ --- CPLD
⑦ --- Formatter
⑧ --- Digital Link
⑨ --- LD driver (LD1/LD2)
⑩ --- Power microprocessor
⑪ --- Interface board FPGA
② --- Serial number
------------ Firmware version ------------
③ --- Main microprocessor
④ --- Sub microprocessor
⑤ --- FPGA (FPGA2/FPGA3)
⑥ --- CPLD
⑦ --- Formatter
⑧ --- Digital Link
⑨ --- LD driver (LD1/LD2)
⑩ --- Power microprocessor
⑪ --- Interface board FPGA
⑫ --- Status of Emulate
------------ DEVICE CHECK ------------
⑬ --- Intake air temperature check (Celsius/Fahrenheit)
⑭ --- DMD temperature check (Celsius/Fahrenheit)
⑮ --- Exhaust air temperature check (Celsius/Fahrenheit)
⑯ --- LD1 temperature check (Celsius)
⑰ --- LD2 temperature check (Celsius)
⑱ --- FPGA temperature check (FPGA2/FPGA3 celsius)
⑲ --- Interface board FPGA temperature check (Celsius)
⑳ --- Power temperature check (NORMAL:OK/HIGH:NG)
㉑ --- LD1 check (1: normal / 0: abnormal)
㉒ --- LD2 check (1: normal / 0: abnormal)
------------ DEVICE CHECK ------------
⑬ --- Intake air temperature check (Celsius/Fahrenheit)
⑭ --- DMD temperature check (Celsius/Fahrenheit)
⑮ --- Exhaust air temperature check (Celsius/Fahrenheit)
⑯ --- LD1 temperature check (Celsius)
⑰ --- LD2 temperature check (Celsius)
⑱ --- FPGA temperature check (FPGA2/FPGA3 celsius)
⑲ --- Interface board FPGA temperature check (Celsius)
⑳ --- Power temperature check (NORMAL:OK/HIGH:NG)
㉑ --- LD1 check (1: normal / 0: abnormal)
㉒ --- LD2 check (1: normal / 0: abnormal)
INF-14
SECTION 1 SERVICE INFORMATION
< RCQ10 / RCQ80 >
OK : FAN
1111 1111 1111 11
R
A
D
IA
TO
R
3
--
-
P
W
1 ---
P
W
2 ---
P
OW
ER
-
--
LD
D
R
IV
ER
--
-
E
X
H
AU
ST
3
---
D
M
D
---
E
X
H
AU
ST
1
---
E
X
H
AU
ST
2
---
R
A
D
IA
TO
R
2
--
-
R
A
D
IA
TO
R
1
--
-
PR
IS
M
---
PU
M
P1
---
PU
M
P
2
---
OK : LD1 1
0
LD
1-
1 -
--
LD
1-
2 -
--
OK : LD2 1 1
LD
2-
1 -
--
LD
2-
2 -
--
LD1-1
LD1-2
LD2-2
LD2-1
EXHAUST3 FAN
EXHAUST2 FAN
EXHAUST1 FAN
RADIATOR1 FAN
POWER FAN
DMD FAN
PRISM FAN
LD DRIVER FAN
PHOSPHOR2 FAN
PHOSPHOR1 FAN
RADIATOR2 FAN
RADIATOR3 FAN
• Items ⑬ to ㉖ indicates the status of "NG" or "OK". If the "NG" indicates in red, the projector has an abnormal-
ity now. If the "OK" indicates in red, the projector had an abnormality in the past and operates normally now.
The item [DEVICE CHECK] also indicates the status as
same as the above.
• To clear the error status, press the [MENU] button in the
SELF CHECK mode, the confirmation window will
appear and select [OK] and press the [ENTER] button.
• This must be done after finishing the repair or maintenance.
CLEAR ERROR INFOMATION ?
OK
CANCEL
EXECUTE
CHANGE
ENTER
㉓ --- Fan check (1: normal / 0: abnormal)
㉔ --- Luminance sensor check (detected value R/G/B/Y)
㉕ --- Atmospheric pressure sensor check (hPa/Celsius)
㉖ --- Angle sensor check (Horizontal angle / Vertical angle)
㉔ --- Luminance sensor check (detected value R/G/B/Y)
㉕ --- Atmospheric pressure sensor check (hPa/Celsius)
㉖ --- Angle sensor check (Horizontal angle / Vertical angle)
w
Details of self-diagnosis
⑯--- LD1 check (1: normal / 0: abnormal)
⑰--- LD2 check (1: normal / 0: abnormal)
⑱--- Fan check (1: normal / 0: abnormal)
INF-15
SECTION 1 SERVICE INFORMATION
< RCQ10 / RCQ80 >
4. AUTO INDEX CALIBRATION
• When replaced the phosphor wheel or color wheel, perform automatic adjustment of each wheel rotational phase.
* Please refer to SECTION 3 (Adjustments) for the procedure.
5. PW1 INDEX
6. PW2 INDEX
7. CW INDEX
6. PW2 INDEX
7. CW INDEX
8. POWER OFF MESSAGE
• Operation setting of shutter at standby operation.
- SHUTTER KEEP: When pushing the standby key while the shutter mode is on, the projector keeps the shutter mode
on and sets into standby mode.
- SHUTTER OPEN: When pushing the standby key while the shutter mode is on, the projector opens the shutter and
displays the "Power OFF confirmation message". (Default setting)
9. ERROR OSD
• Enables to display the error information of the LIGHT indicators on the screen.
(It is useful when using the projector with rear projection mode)
- ON : "LD1/LD2 ERROR" is displayed on the screen if the lighting error occurs.
(It will disappear when any of the control buttons is pressed.)
- OFF : No message is displayed on the screen if the lighting error occurs. (Default setting)
10. MODEL
• Set the model and destination of this projector after replacing the A-PCB.
* This model setting is effective after main power restart.
11. LIGHT ADJUST
• Used when checking the light source. (It is not normally used.)
[LIGHT SELECT]
• You can setup the light source to be lit.
- ALL: All lighting blocks (LD1 / LD2) will light up. (Default setting)
- LD1: Only the lower side of the lighting block (LD1) will be lit.
- LD 2: Only the upper side of the lighting block (LD2) is lit.
* After selection, press the <ENTER> button to switch.
* When the power is turned off , it returns to "ALL". (Default setting)
[TEST PATTERN]
• Display test pattern (all white) for optical adjustment. (For factory adjustment)
12. LIGHT RUNTIME RESET
• When replacing the LD unit with a new one, reset the LD runtime.
This resetting is effective after main power restart.
* Please refer to SECTION 3 (Adjustments) for the procedure.
13. MUTE TIME OFFSET
• Set the extension of black mute time.
It hides the input switching noise.
- DISABLE : Does not extend the mute time. (Default setting)
- 0.5s --- 5.0s : Extension of mute time can be set in 0.5 second steps.
14. INDICATOR SETTING
• Set this when you want to turn off the indicator LED.
[INDICATOR MODE]
- NORMAL : Turn on or off the indicator LED according to the projector status.(Default setting)
- OFF : The indicator will be forcibly turned off.
- TIMEOUT : The indicator turns off when no operation is taken for a setting time.
[NO ACTIVITY TIME]
Setup the time to turn off when INDICATOR MODE setting is TIMEOUT.
You can set the time up to 15 minutes with 1 minute step. (default setting is 15 MIN.)
*If INDICATOR MODE setting is NORMAL or OFF, this will be grayed out.
• Make the rotation phase adjustment of the wheels individually.
(Do not change the setting, usually.)
INF-16
SECTION 1 SERVICE INFORMATION
< RCQ10 / RCQ80 >
15. COMMAND CONTROL TIMEOUT
• Set up the communication specifications of the command control.
- 0SEC : 1 Command 1 session mode. (Default)
- 30SEC : Keeps a session for 30 seconds.
16. DIGITAL LINK OPTION
• Setup when failing the DIGITAL LINK firmware updating. (Normally not used)
- 0 : Normal (Default)
- 1 : Firmware writing mode by the special tool.
17. HDMI HOT PLUG CONTROL
• At the turning on the projector, setup when the abnormal HDMI signal (no information frame, etc.) is output from source
equipment, it controls the Hot Plug and outputs the signal again.
- DISABLE : Hot Plug is "High" during connecting to the source equipment.*1
- POWER ON : Hot Plug is switched from "Low" to "High" once when starting up the main power supply. (Default) *1, *2
*1 : When changing the setting of "EDID Selection" or "EDID Mode" on the HDMI IN menu, the Hop Plug becomes
"Low".
*2 : The source equipment may output the signal again to the connected equipment (monitors, projectors).
18. SAVE LOG
• Save log data to USB memory via USB port.
The saved log data can be checked using the log backup tool.
* Please refer to [5.4.Log acquisition procedure using USB memory] of this section for the procedure.
19. PIXEL SHIFT ADJUST
• Adjusts the smooth pixel drive function when the WOB unit is replaced.
* Please refer to SECTION 3 (Adjustments) for the procedure.
20. BOUNDARY SMOOTHER
• Setting of the gradation smooth processing circuit operation.
- ON : Enable the smooth gradation steps processing. (Default setting)
- OFF : Disable