DOWNLOAD Panasonic PT-EZ590E / PT-EZ590LE / PT-EW650E / PT-EW650LE / PT-EW550E / PT-EX620E / PT-EX620LE / PT-EX520E (serv.man2) Service Manual ↓ Size: 32.15 MB | Pages: 110 in PDF or view online for FREE

Model
PT-EZ590E PT-EZ590LE PT-EW650E PT-EW650LE PT-EW550E PT-EX620E PT-EX620LE PT-EX520E (serv.man2)
Pages
110
Size
32.15 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / LCD PROJECTOR
File
pt-ez590e-pt-ez590le-pt-ew650e-pt-ew650le-pt-ew550.pdf
Date

Panasonic PT-EZ590E / PT-EZ590LE / PT-EW650E / PT-EW650LE / PT-EW550E / PT-EX620E / PT-EX620LE / PT-EX520E (serv.man2) Service Manual ▷ View online

INF-11
SECTION 1 SERVICE INFORMATION
<EZ590/EW650/EW550/EX620/EX520>
1. FREEZE MESSAGE
• Setting the display of on-screen message "FREEZE"
  - ON : Display "FREEZE" message in the freeze mode.
  - OFF : Not display "FREEZE" message in the freeze mode.
2. FAN FULL MODE
• Setting the mode of cooling fan motor to the maximum.
  - ON : Fixed high speed cooling mode
  - OFF : Normal mode (Spinning speed changes depending on the surrounding temperature)
  * It sets OFF at the normal.
  * The highland mode is not available if it sets ON.
3. VGA60/480p
• Setting the switching mode of RGB input signal
  - AUTO : Select VGA60 or 480p of RGB input signal automatically
  - 480p : Select 480p mode forcedly.
  - VGA60 : Select VGA60 mode forcedly.
4. EMULATE
• Setting the serial command format when using other model's serial control commands.
-DEFAULT: Standard
-D3500
-D4000
-D/W5k series
-D/W/Z6k series
-L730 series
-L780 series
-L735 series
-L785 series
-F/W  series
-LZ370
-LB/W  series
-VX500  series
-EZ570  series
-VW431D
-MODE_HI: other company
-MODE_NE: other company
-MODE_EP: other company
-MODE_SA: other company
-MODE_SH: other company
-MODE_MI: other company
-MODE_SO: other company
-MODE_IN: other company
-OTHER:other models
*  Software of sub-microprocessor cannot be updated when the MODE_** (other company) or OTHER is selected in the EMU-
LATE menu.
5. BAUD RATE
• Setting the baud rate of RS232C communication
  - 9600 / -19200 / -38400 / - 57600 / -115200
  * The using baud rate will be set when the OTHER  is selected in the EMULATE menu. (Use 9600 in normal)
6. VERSION
*  The version no. of command will be displayed when the MODE_** (other company) or OTHER is selected in the EMULATE 
menu.
7. INPUT SELECT
* The input select command will be assigned when the MODE_IN is selected in the EMULATE menu.
INF-12
SECTION 1 SERVICE INFORMATION
<EZ590/EW650/EW550/EX620/EX520>
(1) – Firmware version of each microprocessor
   
 MM: Main microprocessor, SM: Sub microprocessor, 
   
NT: Network microprocessor, FPGA: FPGA microprocessor
   
DIGITAL LINK
(2) –  Input signal name
(3) – Input signal frequency (Horizontal / Vertical)
(4)  – Temperature error check
(5) –  Temperature at sensors (Celsius) 
   
 INTK (Intake air) / EXST (Exhaust air) / FLTR (Filter 
clogged)
(6) –  Value of clogged sensor.
(7) – Fan rotation check
   
 INTK (Intake fan) / LAMP (Lamp fan) / EXST (Exhaust fan)/
POWER (Power fan)
(8) – Iris error check (NG: error)
(9) – Lamp error check (NG: error)
(10) – Lamp memory communication check (NG: error)
(11) – Projector accumulated runtime
(12) –  Converted lamp runtime / Lamp on times
   
Current / 1 time before reset / 2 times before reset
(13) – Projector serial no.
(14) –  FPGA version 
(15) –  Version no. of emulate software (when selecting other 
company). [--] means not set.
(16) – Status of correction data in the memories
   
G-SAVED: Gamma correction data
   
U-SAVED: Color shading correction data
(17) –  Temperature at sensors (Celsius) when the latest shut-
down occurred by temp error.
   
 INTK (Intake air) / EXST (Exhaust air) / CLOG (Filter 
clogged)
(18) – Compensation value of filter clog
(19) – Status of lamp replacement time
   
NG:  Lamp runtime exceeds a specified time at lamp power 
normal.
(20) – Lamp runtime reset times
(21) – Actual lamp runtime
   
Current / last time reset / 2nd last time reset
8. SELF CHECK
• Displays the self diagnostic information 
9. TEST PATTERN
• Displays test patterns of White/Red/Green/Blue raster signals,
  - Change the patterns by as buttons, Change the color by qw buttons.
10. FLICKER ADJUST
• Performs the flicker adjustment. (Refer to "SECTION 3 Adjustment")
11. MODEL NO. SETTING
• Setting up the model no. of the projector. (Refer to "SECTION 3 Adjustment")
12. PANEL TYPE SETTING
• Setting up the LCD panel type (L-Type or R-Type). (Refer to "SECTION 3 Adjustment")
13. INPUT AUTO CALIBRATION
•  Performs the auto calibration of input signal level. (For factory inspection purpose)
14. WHITE BALANCE ADJUST
• Adjusts the white balance. (Refer to "SECTION 3 Adjustment")
*  The display information varies depending on the input signal and 
version of the software.
*  The word "OK" of Items (TEMP/FAN/MECHANICAL/LAMP) would 
be indicated in red if the projector had shutdown due to abnormality 
last time.
SELF CHECK  1/2 
S/N  DB1234567
MM: 1.04 
SM: 1.00
NT:  
FPGA: 1.00
DIGITAL LINK : 1.30.90.C
XGA60 
EMULATE   ---
 48.21KHZ 
G-SAVED OK
 59.81HZ 
U-SAVED OK
            ------------- TEMP -----------
TEMP OK
INTK +24.1 
INTK ---
EXST +35.2 
EXST ---
FLTR +42.1 
FLTR.C.V. -1.6
CLOG +56.5 
CLOG ---
            ------------- FAN ------------
R,B /G  /PBS /LAMP /REAR /POWER/EXST OK
            --------- MECHANICAL ---------
IRIS OK
            ------------- LAMP -----------
LAMP OK 
1000H OK
MEMORY OK
            -------- UNIT HISTORY --------
TOTAL 
      1000H 
RESET 
2
 186H20 
238 
  183H30
  0H00 
   0H00
  0H00 
   0H00
(1)
(13)
(16)
(15)
(17)
(18)
(19)
(20)
(21)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(10)
(11)
(12)
(9)
(14)
SELF CHECK  2/2
----------- ASIA MODEL ------------
CONNECTION 
: YES
VERSION 
: 13.00.007
LEVEL 
: +33/-110
UNLOCK 
: YES
LIMIT COUNT 
: 30/30
(23)
(22)
(24)
(25)
(26)
SELF CHECK (Page2)
Switch pages with qw buttons. (Available Asia model only.)
(22) – GSM signal analyzing status
(23) – GSM I firmware version
(24) – Signal level
(25) – Unlock status
(26) – Countdown status of lock
INF-13
SECTION 1 SERVICE INFORMATION
<EZ590/EW650/EW550/EX620/EX520>
15. KEYSTONE CALIBRATION
• Performs the auto keystone calibration. (Refer to "SECTION 3 Adjustment")
16. CLOG SENSOR CALIBRATION
• Performs the calibration of clogged sensor circuit. (Refer to "SECTION 3 Adjustment")
17. VALENS (Only for PT-EZ590, PT-EW650, PT-EX620)
• Displays information about Valens.
18. DIGITAL LINK SETUP (Only for PT-EZ590, PT-EW650, PT-EX620)
• Setting up the communication mode of DIGITAL LINK and the Ethernet.
 
DIGITAL LINK SETUP
DUPLEX(ETHERNET)
 AUTONEGOTIATION
DUPLEX(DIGITAL LINK) 
AUTONEGOTIATION
STORE
Available mode
Description
AUTONEGOTIATION
The communication method is set automatically.
100BaseTX-FUll
Full-duplex communication method is set.
100BaseTX-Half
Half-duplex communication method is set.
 
  - Select the item with as buttons, Change the mode with qw
 buttons.]
    After setting, select [STORE] and press the [ENTER] button to store the mode.
19. RGB PIXEL ADJUST (Only for PT-EZ590)
• Adjusts the convergence. Each pixel cab be moved +- 2 dots vertically and horizontally.
20. GHOST FB CALIBRATION (Only for PT-EZ590)
• Performs the panel ghost feedback calibration. (Refer to "SECTION 3 Adjustment")
21. OPTION
• Setting up the HDMI Selector IC IT6633E Equalizer (0 ~ 63) Initial value: 
6
  - Sets up the Equalizer level of HDMI input signal. Change the equalizer level with qw buttons.
22. HDMI SIG CHG INTR
• Setting up the HDMI signal discriminant specification against static electrical discharge. (1 ~ 31) initial value: 1
  - Change the HDMI signal discriminant period with qw buttons. 
23. CLOG SHUTDOWN
• Setting up the shutdown specification by the clog sensor (ON/OFF) Initial value: ON
  - Switches the function On or Off with qw buttons.
 The specification will change as the below when the function is "OFF".
  1) Disable the function "Transition to Lamp eco mode" and "Shutdown" due to the rising of value of filter clog sensor.
  2) Sets up the filter counter timer to "1000h".
  3) Disable the function of OSD warning message when the filter counter timer reaches the setting value. 
  When setting to "ON", the filter counter timer is set to default and enable the functions on items 1) and 3).
24. FRAME LOCK SS (Only for PT-EZ590)
• Setting up the frame lock function for the SVGA60 signal input. (ON/OFF) Initial value: ON
  - Switches the function On or Off with qw button.
INF-14
SECTION 1 SERVICE INFORMATION
<EZ590/EW650/EW550/EX620/EX520>
4. Notes on service
4. 1. Before service operation
4. 1. 1. LCD panel
1.  The display unit of this projector comprises three LCD panels. Although an LCD panel is a product of high-precision tech-
nology, some of the pixels on the image may be missing or constantly lit. Please note that this is not a failure.
2.  Displaying a still image for a longer time may result in an after-image on the LCD panels. If this happens, display the all 
white screen in the test pattern for an hour or more.
4. 1. 2. Lamp
1. The light source of the projector is a high-pressure mercury lamp.
2. A high-pressure mercury lamp has the following characteristics.
  • The luminance of the lamp will decrease by duration of usage.
  •  The lamp may burst with a loud sound or have its service life shortened because of shock, chipping, or degradation due to 
cumulative runtime.
  •  The lamp life varies greatly depending on individual differences and usage conditions. In particular, continuous use for 12 
hours or more and frequent off/on switching of the power greatly deteriorate the lamp and affects the lamp life.
  • In rare cases, the lamps burst shortly after projection starts.
  •  The risk of bursting increases when the lamp is used beyond its replacement cycle. Make sure to replace the lamp unit 
regularly.
    (Refer to items “When to replace the lamp unit”, “How to replace the lamp unit”)
  • If the lamp bursts, gas contained inside of the lamp is released in the form of smoke.
  • It is recommended that you store the Replacement Lamp Unit as a contingency.
Replacement lamp unit : ET-LAEF100
Note  
*  Panasonic takes no responsibility for any damage or malfunction of the 
product resulting from use of lamp units which are not manufactured by 
Panasonic. Use only specified lamp units.
Attention 
*   Please be sure to read the warnings and notices on the lamp that is 
described in the Operating Instructions. "Read this first!", "Precautions for 
use", "Maintenance/replacement".
4. 1. 3. Air filter unit
1.  Make sure that the air filter unit is properly attached before using the projector. If it is 
not properly attached, the projector will suck in dirt and dust causing a malfunction.
2.  Air filter replacement is recommended after cleaning the unit two times. The dust-
proof properties may be reduced after each cleaning.
3.  The cleaning and replacement cycle of the air filter unit varies depending on the us-
age environment.
Replacement air filter unit : ET-RFE300
4. 1. 4. Lithium battery
1. The lithium battery is used for the internal clock in the A-P.C.Board. So when it consumed it must be replaced.
 
  Lithium battery : CR2032
* Use only specified lithium battery.
* Used battery must be scrapped according to the instruction.
2. After replacing the lithium battery, surely set the "Date and Time" on the sub-menu in the main menu "projector set up".
Page of 110
Display