DOWNLOAD Panasonic PT-DS100XE / PT-DS12KE / PT-DS20K2E / PT-DS20K2EJ / PT-DS20KE / PT-DW11KE / PT-DW17K2E / PT-DW17KE / PT-DW90XE / PT-DZ10KE / PT-DZ110XE / PT-DZ13KE / PT-DZ16K2E / PT-DZ16KE / PT-DZ21K2E / PT-DZ21KE / PT-RQ13KE / PT-RQ22KEJ / PT-RQ32KE / PT-RS11KE / PT-RS30KE / PT-RZ12KE / PT-RZ21KE / PT-RZ31KE Service Manual ↓ Size: 12.5 MB | Pages: 44 in PDF or view online for FREE

Model
PT-DS100XE PT-DS12KE PT-DS20K2E PT-DS20K2EJ PT-DS20KE PT-DW11KE PT-DW17K2E PT-DW17KE PT-DW90XE PT-DZ10KE PT-DZ110XE PT-DZ13KE PT-DZ16K2E PT-DZ16KE PT-DZ21K2E PT-DZ21KE PT-RQ13KE PT-RQ22KEJ PT-RQ32KE PT-RS11KE PT-RS30KE PT-RZ12KE PT-RZ21KE PT-RZ31KE
Pages
44
Size
12.5 MB
Type
PDF
Document
Service Manual / Other
Brand
Device
Projector / 3-CHIP DLP BASED PROJECTOR
File
pt-ds100xe-pt-ds12ke-pt-ds20k2e-pt-ds20k2ej-pt-ds2.pdf
Date

Panasonic PT-DS100XE / PT-DS12KE / PT-DS20K2E / PT-DS20K2EJ / PT-DS20KE / PT-DW11KE / PT-DW17K2E / PT-DW17KE / PT-DW90XE / PT-DZ10KE / PT-DZ110XE / PT-DZ13KE / PT-DZ16K2E / PT-DZ16KE / PT-DZ21K2E / PT-DZ21KE / PT-RQ13KE / PT-RQ22KEJ / PT-RQ32KE / PT-RS11KE / PT-RS30KE / PT-RZ12KE / PT-RZ21KE / PT-RZ31KE Service Manual / Other ▷ View online

DMD chip, FM-PCB and TIR prism Replacing Procedure
DMD chip, FM-PCB and TIR prism Replacing Procedure
17
4. Mount the DMD chip on the alignment plate.
1. Set a new DMD chip on the alignment plate.
2. Apply the adhesive bond at 3 point as like as the original.
[Note]: It takes about 20 minutes or more for dry up the bond completely.
5. Mount the DMD aperture unit on the alignment plate.
E
Alignment plate
Interposer
DMD aperture unit
(Torque: 22±2 N•cm)
Adhesive bond :
3M [DP420] 0.025g
Adhesive bond
Aperture dustproof
Dustproof sheet
Wide cut-
ting part
Ellipse hole side
For PT-RZ12K series
1.  Clean up the surfaces of aperture dustproof and the DMD by using air 
blower or proper chemical cleaner.
2. Attache the interposer on the DMD chip on the aliment plate.
3. Mount the DMD aperture unit on the alignment plate with 2 screws-E.
DMD chip, FM-PCB and TIR prism Replacing Procedure
DMD chip, FM-PCB and TIR prism Replacing Procedure
18
E
Alignment plate
Heat conductive sheet*
(only for G-DMD)
* PT-DZ21K series do not pro-
vide this sheet.
Aperture holder
Interposer
DMD aperture unit
(Torque: 22±2 N•cm)
Aperture dustproof
Dustproof sheet
Wide cut-
ting part
Ellipse hole side
For PT-RZ31K series,  PT-RZ21K series, PT-DZ21K2 series, PT-DZ21K series
1. Stick the heat conductive sheet on the alignment plate. (G-DMD only)
2.  Clean up the surfaces of aperture dustproof and the DMD by using air 
blower or proper chemical cleaner.
3. Attache the interposer on the DMD chip on the aliment plate.
4.  Mount the DMD aperture unit on the alignment plate with 2 aperture 
holders and 6 screws-E.
DMD chip, FM-PCB and TIR prism Replacing Procedure
DMD chip, FM-PCB and TIR prism Replacing Procedure
19
For PT-DZ13K series, PT-DZ8700 series
1.  Clean up the surfaces of aperture unit and the DMD by using air blower or proper chemical cleaner.
2. Attache the interposer on the DMD chip on the aliment plate.
3. Mount the DMD aperture unit on the alignment plate with 2 screws-E.
E
Alignment plate
Interposer
DMD aperture unit
(Torque: 22±2 N•cm)
Ellipse hole side
(Torque: 22±2 N•cm)
DMD Aperture
Aperture 
holder
Wide cut-
ting part
Ellipse hole side
E
E
DMD chip, FM-PCB and TIR prism Replacing Procedure
DMD chip, FM-PCB and TIR prism Replacing Procedure
20
6. Mount the DMD unit without FM-PCB on the DMD block.
1.  Clean up the surface of aperture dustproof on the DMD unit and prism surface of the DMD block by using air blower or proper 
chemical cleaner.
2. Set the DMD unit on the DMD block by guiding the screw drivers as shown in the picture below.
  1) Set 3 convergence adjusting screws on the alignment plate to be 3.5mm distance. (G and R-DMD plate only)
  2)  Set the alignment plate as the 4 holes on the alignment plate comes on the center of the 4 holes on the DMD fixing plate. 
You may align it slightly with the convergence adjusting screws.
3. Tighten 4 screws to fix the DMD unit on the DMD block temporarily.
Guide holes
3.5mm
3.5mm
3.5mm
Fixing holes
Convergence adjust-
ing screws
DMD block
DMD unit fixing screws*
DMD unit fixing screws*
Guide drivers
(3.0mm diameter shaft driv-
ers are recommended)
*  Type of DMD fixing screw differs depend-
ing on the DMD for R, G, or B.
D
D
E.g.: PT-RZ12K series
Caution!
Do not touch the part of the metal pin on the interposer and 
the contact part on the FM-PCB. Cause the poor contact 
outbreak
[Note]: 
•  When loosing screws-D, do not use ball pointed hex driver 
but use 2.0 mm straight hex driver and special wrench 
(DPKW1001Z) for the longer screws.
Screw
Type
Parts No.
Screw D
Long type THEL138
Short type THEL139
Screw F -
XVE2B6FP
F
Page of 44
Display

Click on the first or last page to see other PT-DS100XE / PT-DS12KE / PT-DS20K2E / PT-DS20K2EJ / PT-DS20KE / PT-DW11KE / PT-DW17K2E / PT-DW17KE / PT-DW90XE / PT-DZ10KE / PT-DZ110XE / PT-DZ13KE / PT-DZ16K2E / PT-DZ16KE / PT-DZ21K2E / PT-DZ21KE / PT-RQ13KE / PT-RQ22KEJ / PT-RQ32KE / PT-RS11KE / PT-RS30KE / PT-RZ12KE / PT-RZ21KE / PT-RZ31KE service manuals if exist.