Panasonic TH-103PF12W / TH-103PF12T Service Manual ▷ View online

49
TH-103PF12W / TH-103PF12T
22. Disconnect the connectors (DS4, DS6).
23. Remove 3 screws and then remove the Slot Block.
24. Disconnect the connectors of P-Board (Main_1) (CM1,
CM2, CM3, CM4, CM5, P2).
25. Disconnect the connector of C5-Board (lower) (C55).
26. Remove 10 screws and then remove P-Board (MAIN_1).
27. Disconnect the connector of C5-Board (upper) (C55).
28. Disconnect the connectors of P-Board (Main_2) (CM1,
CM2, CM3, CM4, P6, P11).
29. Remove 10 screws and then remove P-Board (MAIN_2).
30. Disconnect the connectors (P9, P25).
31. Remove 9 screws and then remove P-Board (SUB).
32. Remove Duct Barrier K.
33. Disconnect the connector (SS21).
34. Remove the flexible cables from the connectors (D20,
D31, D32, D33, D34).
35. Remove 4 screws and then remove D-Board.
50
TH-103PF12W / TH-103PF12T
36. Remove 4 screws and then remove PB-Board.
37. Remove 2 screws and then remove AC Inlet Cover.
38. Remove 3 screws and then remove the AC Inlet.
39. Remove 8 screws and then remove the Fan Box (A, B).
40. Remove the Duct Barrier E, Duct Barriers F, Duct Barrier
G, Duct Barrier H, Duct Barrier L, Duct Barrier N and Duct
Barrier O.
41. Exchange the Plasma Display Panel.
51
TH-103PF12W / TH-103PF12T
10 Measurements and Adjustments
10.1. Adjustment Procedure
10.1.1. Driver Set-up
10.1.1.1. Item / Preparation
1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
Caution
1. First perform Vsus adjustment.
2. Confirmation of Vscn voltage should be performed after
confirmation of Vad adjustment.
When Vad=-135V, Voltage of Vscn is +10V ±4V.
10.1.1.2. Adjustments
Adjust driver section voltages. (Refer to the panel data on the
Panel Label).
Check or adjust the following voltages with the multimeter. 
*See the Panel Label.
**See chap. 10.1.6.
Name
Test Point
Voltage
Volume
Remarks
Vsus
(SC side)
TPVSUS 
(SC)
Vsus ± 2V
VR251 
(P_Main_1)
*
Vsus
(SS side)
TPVSUS 
(SS)
Vsus ± 2V
VR251 
(P_Main_2)
*
Ve**
TPVE (SS)
Ve ± 1V
VR16001
(SS)
*
Vda
TP9 
(P_Main_1)
70V +1V, -2V Fixed
TP9 
(P_Main_2)
70V +1V, -2V Fixed
Vad
TPVAD (SC) -135V ± 1V
VR16600 
(SC)
Vscn
TPVSCN 
(SC)
Vad_base:
+145V±4V
GND_base: 
 +10V±6V
Fixed
52
TH-103PF12W / TH-103PF12T
10.1.2. Initialization Pulse Adjust
1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
3. Connect Oscilloscope to TPSC1 and adjust VR16601 for 125V ± 5V.
Test Point
Volume
Level
TPSC1 (SC)
VR16601 (SC)
125V ± 5V
at 50 
µs 
period on the down slope.