8.5.15.
Paper Sensor
6. Unhook the 2 hooks of Hopper Plate.
1. Remove the Hopper Plate. (See 8.5.14.)
2. Remove the 2 screws to release the Paper Sensor with plate
from the Hopper Plate Assembly.
from the Hopper Plate Assembly.
3. Remove the screw to separate the sensor from the plate, and
then disconnect the Connector.
then disconnect the Connector.
82
8.5.16.
Conveyor bottom
8.5.17.
USR SENSOR Board
8.5.18.
DFP Pressure Motor
1. Remove the Hopper Plate. (See 8.5.14.)
2. Remove the 2 screws.
3. Remove the Conveyor bottom.
1. Remove the Conveyor bottom. (See 8.5.16.)
2. Remove the screw, and then disconnect the connector.
1. Remove the Left Cover. (See 8.5.10.)
2. Remove the Conveyor bottom. (See 8.5.16.)
3. Remove the USR SENSOR Board. (see 8.5.17.)
4. Remove the UL Tape.
5. Remove the connector from □ Hole.
6. Remove the screw(a) and 4 screws(b) on the Reinforcement
Plate.
Plate.
83
7. Remove the screw (a) on the left side.
8. Pull upward and remove the Reinforcement Plate.
9. Remove the screw(a), and take out DFP motor cover plate.
10. Remove the 2 screws(b), and then raise the DFP Pressure
Motor with plate.
Motor with plate.
84
8.5.19.
DFP HOME SENSOR Board
8.5.20.
Inner Cover C
11. Disconnect the connector, and then remove the 2 screws to
release the motor from the plate.
release the motor from the plate.
1. Remove the DFP Pressure Motor. (See 8.5.18.)
2. Remove the screw, and then disconnect the connector of the
DFP HOME SENSOR Board.
DFP HOME SENSOR Board.
3. Remove the Poly-slider and Hopper Cam Shutter.
4. Remove the DFP HOME SENSOR Board.
1. Remove the 2 screws that fasten the Inner Cover C to the
scanner.
scanner.
2. Push down the cover to remove it.
Click on the first or last page to see other KV-S5076H / KV-S5046H service manuals if exist.