Panasonic KV-S5076H / KV-S5046H Service Manual ▷ View online
69
8.4.15.
SKEW SENSOR (L), (R) Board
8.4.16.
HOPPER POSITION SENSOR Board
1. Remove the Paper Feed Motor. (See 8.4.12.)
2. Remove the 2 screws.
3. Release the 2 connectors.
4. Remove SKEW SENSOR (L), (R) Board.
1. Remove the Top Cover. (See 8.4.7.)
2. Release the cable from clamper.
3. Disconnect the connector.
4. Remove the screw.
5. Remove the HOPPER POSITION SENSOR Board.
70
8.5.
Lower Block
8.5.1.
Right Cover (with Right Front Cover)
1. Remove the 2 screws on the right side of the scanner.
2. Push the ADF Door Release to open the ADF Door
3. Remove the screw (a) and screw (b).
4. While slightly flexing the rear of the Right Cover in the
direction of the arrow (1) and holding up the cover in the
direction of the arrow (2), pull the cover forward.
direction of the arrow (1) and holding up the cover in the
direction of the arrow (2), pull the cover forward.
71
8.5.2.
Right Front Cover
8.5.3.
PANEL Board
5. Disconnect the connector from the PANEL Board to release
the Right Cover (with Right Front Cover) from the scanner.
the Right Cover (with Right Front Cover) from the scanner.
1. Remove the Right Cover with Right Front Cover. (See 8.5.1.)
2. Remove the 3 screws to release the Right Front Cover from
the Right Cover.
the Right Cover.
1. Remove the Right Front Cover. (See 8.5.2.)
2. Remove the 4 screws to release the Panel Cover from the
Right Front Cover.
Right Front Cover.
72
8.5.4.
FAN
8.5.5.
Micro Switch
3. Remove the 3 screws on the PANEL Board.
1. Remove the Right Cover (with Right Front Cover).
(See 8.5.1.)
(See 8.5.1.)
2. Remove the 2 screws.
3. Disconnect the connector from the POWER Board.
(See 8.5.7.)
(See 8.5.7.)
1. Remove the Right Cover (with Right Front Cover).
(See 8.5.1.)
(See 8.5.1.)
2. Disconnect the connector.
3. Remove the 2 screws and the Micro Switch.
Click on the first or last page to see other KV-S5076H / KV-S5046H service manuals if exist.