Panasonic KV-S5055C (serv.man2) Service Manual ▷ View online
97
Image Sensor
Output
Output
1. Click “Image Sensor Output” on the main menu.
2. Push the ADF Door Release to open the ADF Door. And
hold a sheet of clean white paper between the Scanning
Glass (F) and Scanning Glass (B), and then close the ADF
Door.
2. Push the ADF Door Release to open the ADF Door. And
hold a sheet of clean white paper between the Scanning
Glass (F) and Scanning Glass (B), and then close the ADF
Door.
3. Set the value of “Gain”. (Value:10 to 120)
4. Select a side (Front or Back).
5. Click “START” on the “Image Sensor Output” dialog box to
start monitoring the image output level graph.
6. Click “STOP” on the “Image Sensor Output” dialog box to
finish the test.
7. Click “Close” to return to the main menu.
8. Open the ADF Door, and then remove the paper.
4. Select a side (Front or Back).
5. Click “START” on the “Image Sensor Output” dialog box to
start monitoring the image output level graph.
6. Click “STOP” on the “Image Sensor Output” dialog box to
finish the test.
7. Click “Close” to return to the main menu.
8. Open the ADF Door, and then remove the paper.
—
Note:
This operation indicates a
sensor output waveform
to check whether there is
any partial depression of
the level.
If the waveform has any
partial depression, clean
the surface of the
Scanning Glass (F) or
Scanning Glass (B).
sensor output waveform
to check whether there is
any partial depression of
the level.
If the waveform has any
partial depression, clean
the surface of the
Scanning Glass (F) or
Scanning Glass (B).
When setting "Shading
Correction" by checking
check-box, the image
sensor output-level after
shading correction can be
seen.
Correction" by checking
check-box, the image
sensor output-level after
shading correction can be
seen.
Double Feed
1. Click “Double Feed” for “Test” item on the main menu.
2. Set “Send Level” on “Double Feed Sensor” dialog box.
3. Push the ADF Door Release to open the ADF Door.
And hold a piece of clean white paper between Scanning
Glass (F) and Scanning Glass (B), and then close the ADF
Door.
4. Click “START” on the “Double Feed Sensor” dialog box to
start the double feed sensor’s sensitivity test.
5. Check whether the peak level is within the specification.
(See Remarks.)
6. Click “STOP” to finish this test.
7. Push the ADF Door Release to open the ADF Door.
And remove the white paper, and then close the ADF Door.
8. Click “Close” to return to the main menu.
3. Push the ADF Door Release to open the ADF Door.
And hold a piece of clean white paper between Scanning
Glass (F) and Scanning Glass (B), and then close the ADF
Door.
4. Click “START” on the “Double Feed Sensor” dialog box to
start the double feed sensor’s sensitivity test.
5. Check whether the peak level is within the specification.
(See Remarks.)
6. Click “STOP” to finish this test.
7. Push the ADF Door Release to open the ADF Door.
And remove the white paper, and then close the ADF Door.
8. Click “Close” to return to the main menu.
—
Memory
1. Click “Memory” on the main menu.
2. Click “START” on the “Memory” dialog box to start Memory
Read / Write Test.
3. Check the result.
4. Click “Close” to return to the main menu.
2. Click “START” on the “Memory” dialog box to start Memory
Read / Write Test.
3. Check the result.
4. Click “Close” to return to the main menu.
—
For details on Error Codes,
refer to Sec. 9.3.2.
refer to Sec. 9.3.2.
Ionizer
1. Click “Ionizer” on the main menu.
2. Click “START” on the “Ionizer Test” dialog box to start
Ionizer ON /OFF Test.
3. Check the result.
4. Click “Close” to return to the main menu.
2. Click “START” on the “Ionizer Test” dialog box to start
Ionizer ON /OFF Test.
3. Check the result.
4. Click “Close” to return to the main menu.
—
Note:
This test does not starts
until the ADF Door is
closed.
until the ADF Door is
closed.
Item
Operation
Default
Remarks
98
9.3.7.
Adjustment
Item
Operation
Default
Remarks
Shading
1. Click “Shading” on the main menu.
2. Confirm the message “The data of User Shading will be
also overwritten” on the display.
And if the message is acceptable, click “OK”.
Note:
2. Confirm the message “The data of User Shading will be
also overwritten” on the display.
And if the message is acceptable, click “OK”.
Note:
This procedure is avaiable only after executing User
Shading.
Shading.
3. Clean the conveyor, rollers, Scanning Glass (F), and
Scanning Glass (B) according to the message on the display.
And click “OK”.
4. Reverse Reference Plates to white according to the message
on the display.
And click “OK”.
5. Set the accessory Shading Sheet or Shading Sheet
(Part No.: See 14.8.) on the Hopper in landscape
orientation.
6. And click “OK” to scan the Shading Sheet.
7. Reverse the Reference Plates to black according to the
message on the display.
8. Click “OK” to return to the main menu.
Scanning Glass (B) according to the message on the display.
And click “OK”.
4. Reverse Reference Plates to white according to the message
on the display.
And click “OK”.
5. Set the accessory Shading Sheet or Shading Sheet
(Part No.: See 14.8.) on the Hopper in landscape
orientation.
6. And click “OK” to scan the Shading Sheet.
7. Reverse the Reference Plates to black according to the
message on the display.
8. Click “OK” to return to the main menu.
—
Until this process is
completed, don’t stop the
process by opening any
doors or turning off the
scanner.
completed, don’t stop the
process by opening any
doors or turning off the
scanner.
All Position
1. Set 2 pcs of test chart A (Part No.: See 14.8.) on the Hopper
in portrait orientation.
2. Click “All position” on the main menu to execute scanning
position, length, width, and paper end adjustment.
3. Check the result.
4. Click “OK” to return to the main menu.
in portrait orientation.
2. Click “All position” on the main menu to execute scanning
position, length, width, and paper end adjustment.
3. Check the result.
4. Click “OK” to return to the main menu.
—
Set 2 pcs of test chart A in
order.
1st page: Front side
2nd page: Back side
order.
1st page: Front side
2nd page: Back side
99
Individual Position 1. Adjust Automatically.
a. Set test chart A (Part No.: See 14.8.) on the Hopper.
b. Click “Individual Position” on the main menu.
c. Click one of 8 “Adjust Automatically” buttons on the
“Individual Position” dialog box to execute the
adjustment.
d. Check the result.
e. Click “OK” to finish the adjustment.
f. Click “OK” to return to the main menu.
b. Click “Individual Position” on the main menu.
c. Click one of 8 “Adjust Automatically” buttons on the
“Individual Position” dialog box to execute the
adjustment.
d. Check the result.
e. Click “OK” to finish the adjustment.
f. Click “OK” to return to the main menu.
2. Adjust Manually.
a. Click “Individual Position” on the main menu.
b. Change the parameter (mm,%) on the “Individual
Position” dialog box as required. (Refer to Remarks.)
c. Click “OK” to renew the setting, and to return to the
main menu.
a. Click “Individual Position” on the main menu.
b. Change the parameter (mm,%) on the “Individual
Position” dialog box as required. (Refer to Remarks.)
c. Click “OK” to renew the setting, and to return to the
main menu.
—
1. “Adjust Automatically”
a. Length
b. Paper End Position
c. Front Paper Width
d. Front V. Position
e. Front H. Position
f. Back Paper Width
g. Back V. Position
h. Back H. Position
2. Adjust Manually
(Length)
+: Increasing the number
makes the scanning
document length shorter.
a. Length
b. Paper End Position
c. Front Paper Width
d. Front V. Position
e. Front H. Position
f. Back Paper Width
g. Back V. Position
h. Back H. Position
2. Adjust Manually
(Length)
+: Increasing the number
makes the scanning
document length shorter.
(Vertical Position)
+: Increasing the number
makes the document
scanning position shifted
upward.
+: Increasing the number
makes the document
scanning position shifted
upward.
(Horizontal Position)
+: Increasing the number
makes the document
scanning position shifted
to the left.
+: Increasing the number
makes the document
scanning position shifted
to the left.
(Paper End Position)
+: On the LC (Length
Control) mode,
increasing the number
allows the paper-end
timing to be earlier
+: On the LC (Length
Control) mode,
increasing the number
allows the paper-end
timing to be earlier
.
(Width)
-: Decreasing the number
extends the scanning
document width.
Note
If the appropriate
scanning position can
not be obtained by any
of the manual
adjustments, check
installation.
scanning position can
not be obtained by any
of the manual
adjustments, check
installation.
Item
Operation
Default
Remarks
100
Double Feed
1. Adjust Automatically.
a. Set the Shading Sheet (Part No.: See 14.8.) on the
Hopper in portrait orientation, sliding the Document
Guides so that they match the document width.
b. Click “Double Feed” in “Adjust” section on the main
menu.
c. Click “Adjust Automatically” on the “Double Feed
Sensor” dialog box to adjust the double feed sensitivity.
d. Check the result.
e. Click “OK” to finish the adjustment.
f. Click “OK” on the “Double Feed Sensor” dialog box to
return to the main menu.
a. Set the Shading Sheet (Part No.: See 14.8.) on the
Hopper in portrait orientation, sliding the Document
Guides so that they match the document width.
b. Click “Double Feed” in “Adjust” section on the main
menu.
c. Click “Adjust Automatically” on the “Double Feed
Sensor” dialog box to adjust the double feed sensitivity.
d. Check the result.
e. Click “OK” to finish the adjustment.
f. Click “OK” on the “Double Feed Sensor” dialog box to
return to the main menu.
2. Adjust Manually.
a. Click “Double Feed” in the “Adjust “ section on the main
menu.
b. Change parameter (Send Level) on the
“Double Feed Sensor” dialog box, as required.
c. Click “OK” on the “Double Feed Sensor” dialog box to
return to the main menu.
a. Click “Double Feed” in the “Adjust “ section on the main
menu.
b. Change parameter (Send Level) on the
“Double Feed Sensor” dialog box, as required.
c. Click “OK” on the “Double Feed Sensor” dialog box to
return to the main menu.
—
Item
Operation
Default
Remarks