97
Image Sensor
Output
1. Click “Image Sensor Output” on the main menu.
2. Push the ADF Door Release to open the ADF Door. And
    hold a sheet of clean white paper between the Scanning
    Glass (F) and Scanning Glass (B), and then close the ADF
     Door.
3. Set the value of “Gain”. (Value:10 to 120)
4. Select a side (Front or Back). 
5. Click “START” on the “Image Sensor Output” dialog box to
   start monitoring the image output level graph.
6. Click “STOP” on the “Image Sensor Output” dialog box to
    finish the test.
7. Click “Close” to return to the main menu.
8. Open the ADF Door, and then remove the paper.
Note:
This operation indicates a
sensor output waveform
to check whether there is
any partial depression of
the level.
If the waveform has any
partial depression, clean
the surface of the
Scanning Glass (F) or
Scanning Glass (B).
When setting "Shading
Correction" 
by checking
check-box, the image
sensor output-level after
shading correction can be
seen.    
Double Feed 
1. Click “Double Feed” for “Test” item on the main menu. 
2. Set “Send Level” on “Double Feed Sensor” dialog box.
3. Push the ADF Door Release to open the ADF Door.
   And hold a piece of clean white paper between Scanning
   Glass (F) and Scanning Glass (B), and then close the ADF
    Door.
4. Click “START” on the “Double Feed Sensor” dialog box to
    start the double feed sensor’s sensitivity test. 
5. Check whether the peak level is within the specification.
    (See Remarks.) 
6. Click “STOP” to finish this test.
7. Push the ADF Door Release to open the ADF Door.
    And remove the white paper, and then close the ADF Door.
8. Click “Close” to return to the main menu.
Memory
1. Click “Memory” on the main menu.
2. Click “START” on the “Memory” dialog box to start Memory
     Read / Write Test.
3. Check the result.
4. Click “Close” to return to the main menu.
For details on Error Codes,
refer to Sec. 9.3.2.
Ionizer
1. Click “Ionizer” on the main menu.
2. Click “START” on the “Ionizer Test” dialog box to start
     Ionizer ON /OFF Test.
3. Check the result.
4. Click “Close” to return to the main menu.
 Note:
This test does not starts 
until the ADF Door is 
closed.
Item
Operation
Default
Remarks
98
9.3.7.
Adjustment
Item
Operation
Default
Remarks
Shading
1. Click “Shading” on the main menu.
2. Confirm the message “The data of User Shading will be
    also overwritten”
 on the display.
    And if the message is acceptable, click “OK”.
     Note:
  This procedure is avaiable only after executing User
  Shading. 
3. Clean the conveyor, rollers, Scanning Glass (F), and
     Scanning Glass (B) according to the message on the display.
     And click “OK”.
4. Reverse Reference Plates to white according to the message
    on the display.
    And click “OK”.
5. Set the accessory Shading Sheet or Shading Sheet
   (Part No.: See 14.8.) on the Hopper in landscape
    orientation.
6. And click “OK” to scan the Shading Sheet.
7. Reverse the Reference Plates to black according to the
    message on the display.
8. Click “OK” to return to the main menu.
Until this process is
completed, don’t stop the
process by opening any
doors or turning off the
scanner. 
All Position
1. Set 2 pcs of test chart A (Part No.: See 14.8.) on the Hopper
    in portrait orientation.
2. Click “All position” on the main menu to execute scanning
    position, length, width, and paper end adjustment. 
3. Check the result.
4. Click “OK” to return to the main menu.
Set 2 pcs of test chart A in
order.
 1st page: Front side
 2nd page: Back side
99
Individual Position 1. Adjust Automatically.
    a. Set test chart A (Part No.: See 14.8.) on the Hopper.
    b. Click “Individual Position” on the main menu.
    c. Click one of 8 “Adjust Automatically” buttons on the
        “Individual Position” dialog box to execute the
        adjustment.
    d. Check the result.
    e. Click “OK” to finish the adjustment.
     f. Click “OK” to return to the main menu.
2. Adjust Manually.
    a. Click “Individual Position” on the main menu.
    b. Change the parameter (mm,%) on the “Individual
        Position”
 dialog box as required. (Refer to Remarks.)
    c. Click “OK” to renew the setting, and to return to the
        main menu. 
1. “Adjust Automatically”
     a. Length
     b. Paper End Position
     c. Front Paper Width
     d. Front V. Position
     e. Front H. Position
     f. Back Paper Width   
     g. Back V. Position
     h. Back H. Position
 
2. Adjust Manually
   (Length)
    +: Increasing the number
        makes the scanning
        document length shorter.
  (Vertical Position)
     +: Increasing the number
         makes the document
         scanning position shifted
         upward.
  (Horizontal Position)
     +: Increasing the number
         makes the document
         scanning position shifted
          to the left.
  (Paper End Position)
     +: On the LC (Length
        Control) mode,
        increasing the number
        allows the paper-end
         timing to be earlier
 
   (Width)
      -: Decreasing the number
         extends the scanning
          document width.
Note
If the appropriate
scanning position can
not be obtained by any
of the manual
adjustments, check 
installation.
Item
Operation
Default
Remarks
100
Double Feed
1. Adjust Automatically.
    a. Set the Shading Sheet (Part No.: See 14.8.) on the
        Hopper in portrait orientation, sliding the Document
        Guides so that they match the document width.
     b. Click “Double Feed” in “Adjust” section on the main
        menu.
    c. Click “Adjust Automatically” on the “Double Feed
        Sensor” dialog box to adjust the double feed sensitivity.
    d. Check the result.
    e. Click “OK” to finish the adjustment.
    f. Click “OK” on the “Double Feed Sensor” dialog box to
        return to the main menu. 
        
2. Adjust Manually.
    a. Click “Double Feed” in the “Adjust “ section on the main
        menu.
    b. Change parameter (Send Level) on the 
        “Double Feed Sensor” dialog box, as required.
    c. Click “OK” on the “Double Feed Sensor” dialog box to
        return to the main menu. 
Item
Operation
Default
Remarks
Page of 127