1-1-3-16
1
1
Simultaneous (Double-Twin) -Type
1-1.  Unit Specifications
PE1
3. Wall Mounted Type S-36PK2E5B×4 / U-125PE1E8A
INDOOR
MODEL
S-36PK2E5B×4
-
-
PANEL
MODEL
-
-
-
OUTDOOR
MODEL
-
U-125PE1E8A
-
Branch pipe
MODEL
CZ-P155BK1×3
Performance test condition
ISO5151  /  EN14511  /  EN12102  /  EN14825
Power supply
Ø, Hz
1Ø 50Hz
3Ø 50Hz
V
220
230
240
380
400
415
Min
Max
C
O
O
L
I
N
G
Capacity
kW
12.5 
12.5 
12.5 
-
-
-
3.3 
14.0 
BTU/h
42700
42700
42700
-
-
-
11300
47800
Current
A
0.35×4
0.34×4
0.33×4
5.75 
5.55 
5.40 
-
-
Input power
W
20×4
20×4
20×4
3.685k
3.685k
3.685k
-
-
TOTAL W
-
3.765k
3.765k
3.765k
840
4.600k
Annual consumption
TOTAL kWh *
4
-
-
-
-
1882.5
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.32 
3.32/A
3.32 
3.93
3.04
Erp
*
6
Pdesign
kW
-
-
-
-
12.5 
-
-
-
η 
s,c
%
-
-
-
-
240.3 
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
97 
96 
95 
-
-
Noise indoor
dB-A (H/M/L) *
7
35/31/27
-
-
-
Power Level dB
51/47/43
-
-
-
Noise outdoor
dB-A (H/L)
-
53/-
-
-
Power Level dB
-
70/-
-
-
H
E
A
T
I
N
G
Capacity
kW
14.0 
14.0 
14.0 
-
-
-
4.1 
16.0 
BTU/h
47800
47800
47800
-
-
-
14000
54600
Current
A
0.36×4
0.35×4
0.34×4
5.75 
5.55
5.40
-
-
Input power
W
20×4
20×4
20×4
3.685k
3.685k
3.685k
-
-
TOTAL W
-
3.765k
3.765k
3.765k
900
5.200k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.72 
3.72/A
3.72 
4.56
3.08
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
12.5 
-
-
-
Tbivalent
°C
-
-
-
-
-9 
-
-
-
η 
s,h
%
-
-
-
-
140.5 
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
97 
96 
95 
-
-
Noise indoor
dB-A (H/M/L) *
7
35/31/27
-
-
-
Power Level dB
51/47/43
-
-
-
Noise outdoor
dB-A (H/L)
-
53/-
-
-
Power Level dB
-
70/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
0.36/20×4
0.35/20×4
0.34/20×4
10.0/ 6.20k
10.0/6.50k
10.0/6.75k
-
Starting current(A) / Comp output(W)
-
-
-
5.75/3.0k
5.55/3.0k
5.40/3.0k
-
Network Impedance(ΩMAX.)
-
-
-
Fan motor output (Indoor/Outdoor) W
54
90× 2
-
Moisture removal volume
L/h(Pt/h)
3.6
(0.9×4)
(7.4)
-
-
External static pressure
Pa
-
-
-
Indoor  
Air flow *
7
Cooling
m³/min (ft³/min)
13.0×4/11.0×4/9.0×4 (459)×4/(388)×4/(318)×4
-
-
-
Heating
m³/min (ft³/min)
13.0×4/11.0×4/9.0×4 (459)×4/(388)×4/(318)×4
-
-
-
Outdoor  
Air flow
Cooling
m³/min (ft³/min)
-
130.0 (4591)
-
-
Heating
m³/min (ft³/min)
-
110.0 (3885)
-
-
Refrigerant type / amount g(oz)
-
R410A  
3.40k
(119.9)
-
Product dimension
Height mm(inch)
302 
(11-29/32)
1416 (55-3/4)
-
Width
mm(inch)
1120 
(44-3/32)
940 (37-1/32)
-
Depth
mm(inch)
236 
(9-9/32)
340 (13-13/32)
-
Product dimension (Panel) H×W×D mm, inch
-
-
Packing dimension
Height mm(inch)
282 
(11-1/8)
1556 
-
Width
mm(inch)
1190 
(46-7/8)
1055 
-
Depth
mm(inch)
378 
(14-29/32)
485 
-
Weight
(NET)
kg(lb)
13 
(29)
98
(216)
-
(GROSS)  kg(lb)
16 
(36)
108
(238)
-
Panel (NET)  kg(lb)
-
-
-
Layers limit (actually)
11 (12)
1(2)
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)Ø6.35(1/4) (Gas)Ø12.7(1/2)
(Liquid)Ø9.52(3/8) (Gas)Ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range     m (ft)
5 ~ 75m (16.4 ~246.1)
-
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m (0.538)
-
Pipe length for additional gas  m (ft)
20m (65.6)
-
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6  
η 
s,c
 and 
η 
s,h
 classification is at 230V(400V) only in accordance with EN-14825. For heating, 
η 
s,h
 indicates the value of only Average heating season.
*7 H: High at setting 5 stage (Level 5), M: Middle at setting 5 stage (Level 3), L: Low at setting 5 stage (Level 1)
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   16
19/09/26   17:01:29
1-1-3-17
1
1
Simultaneous (Triple) -Type
1-1.  Unit Specifications
PE1
3. Wall Mounted Type S-45PK2E5B×3 / U-125PE1E8A
INDOOR
MODEL
S-45PK2E5B×3
-
-
PANEL
MODEL
-
-
-
OUTDOOR
MODEL
-
U-125PE1E8A
-
Branch pipe
MODEL
CZ-P3HPC2
Performance test condition
ISO5151  /  EN14511  /  EN12102  /  EN14825
Power supply
Ø, Hz
1Ø 50Hz
3Ø 50Hz
V
220
230
240
380
400
415
Min
Max
C
O
O
L
I
N
G
Capacity
kW
12.5 
12.5 
12.5 
-
-
-
3.3 
14.0 
BTU/h
42700
42700
42700
-
-
-
11300
47800
Current
A
0.38×3
0.37×3
0.36×3
5.75 
5.55 
5.40 
-
-
Input power
W
30×3
30×3
30×3
3.675k
3.675k
3.675k
-
-
TOTAL W
-
3.765k
3.765k
3.765k
840
4.600k
Annual consumption
TOTAL kWh *
4
-
-
-
-
1882.5
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.32 
3.32/A
3.32 
3.93
3.04
Erp
*
6
Pdesign
kW
-
-
-
-
12.5 
-
-
-
η 
s,c
%
-
-
-
-
240.3 
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
97 
96 
95 
-
-
Noise indoor
dB-A (H/M/L) *
7
38/34/30
-
-
-
Power Level dB
54/50/46
-
-
-
Noise outdoor
dB-A (H/L)
-
53/-
-
-
Power Level dB
-
70/-
-
-
H
E
A
T
I
N
G
Capacity
kW
14.0 
14.0 
14.0 
-
-
-
4.1 
16.0 
BTU/h
47800
47800
47800
-
-
-
14000
54600
Current
A
0.38×3
0.37×3
0.36×3
5.75 
5.55
5.40
-
-
Input power
W
30×3
30×3
30×3
3.675k
3.675k
3.675k
-
-
TOTAL W
-
3.765k
3.765k
3.765k
900
5.200k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.72 
3.72/A
3.72 
4.56
3.08
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
12.5 
-
-
-
Tbivalent
°C
-
-
-
-
-9 
-
-
-
η 
s,h
%
-
-
-
-
140.5 
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
97 
96 
95 
-
-
Noise indoor
dB-A (H/M/L) *
7
38/34/30
-
-
-
Power Level dB
54/50/46
-
-
-
Noise outdoor
dB-A (H/L)
-
53/-
-
-
Power Level dB
-
70/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
0.38/30×3
0.37/30×3
0.36/30×3
10.0/ 6.20k
10.0/6.50k
10.0/6.75k
-
Starting current(A) / Comp output(W)
-
-
-
5.75/3.0k
5.55/3.0k
5.40/3.0k
-
Network Impedance(ΩMAX.)
-
-
-
Fan motor output (Indoor/Outdoor) W
54
90× 2
-
Moisture removal volume
L/h(Pt/h)
4.5
(1.5×3)
(9.5)
-
-
External static pressure
Pa
-
-
-
Indoor  
Air flow *
7
Cooling
m³/min (ft³/min)
14.5×3/12.5×3/10.3×3 (512)×3/(441)×3/(364)×3
-
-
-
Heating
m³/min (ft³/min)
14.5×3/12.5×3/10.3×3 (512)×3/(441)×3/(364)×3
-
-
-
Outdoor  
Air flow
Cooling
m³/min (ft³/min)
-
130.0 (4591)
-
-
Heating
m³/min (ft³/min)
-
110.0 (3885)
-
-
Refrigerant type / amount g(oz)
-
R410A  
3.40k
(119.9)
-
Product dimension
Height mm(inch)
302 
(11-29/32)
1416 (55-3/4)
-
Width
mm(inch)
1120 
(44-3/32)
940 (37-1/32)
-
Depth mm(inch)
236 
(9-9/32)
340 (13-13/32)
-
Product dimension (Panel) H×W×D mm, inch
-
-
Packing dimension
Height mm(inch)
282 
(11-1/8)
1556 
-
Width
mm(inch)
1190 
(46-7/8)
1055 
-
Depth
mm(inch)
378 
(14-29/32)
485 
-
Weight
(NET)
kg(lb)
13 
(29)
98
(216)
-
(GROSS)  kg(lb)
16 
(36)
108
(238)
-
Panel (NET)  kg(lb)
-
-
-
Layers limit (actually)
11(12)
1(2)
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)Ø6.35(1/4) (Gas)Ø12.7(1/2)
(Liquid)Ø9.52(3/8) (Gas)Ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range     m (ft)
5 ~ 75m (16.4 ~246.1)
-
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m (0.538)
-
Pipe length for additional gas  m (ft)
20m (65.6)
-
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6  
η 
s,c
 and 
η 
s,h
 classification is at 230V(400V) only in accordance with EN-14825. For heating, 
η 
s,h
 indicates the value of only Average heating season.
*7 H: High at setting 5 stage (Level 5), M: Middle at setting 5 stage (Level 3), L: Low at setting 5 stage (Level 1)
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   17
19/09/26   17:01:30
1-1-3-18
1
1
Simultaneous (Twin) -Type
1-1.  Unit Specifications
PE1
3. Wall Mounted Type S-50PK2E5B×2 / U-100PE1E8A
INDOOR
MODEL
S-50PK2E5B×2
-
-
PANEL
MODEL
-
-
-
OUTDOOR
MODEL
-
U-100PE1E8A
-
Branch pipe
MODEL
CZ-P155BK1
Performance test condition
ISO5151 / EN14511 / EN12102/ EN14825
Power supply
Ø, Hz
1Ø 50Hz
3Ø 50Hz
V
220
230
240
380
400
415
Min
Max
C
O
O
L
I
N
G
Capacity
kW
10.0 
10.0 
10.0 
-
-
-
3.3 
12.5 
BTU/h
34100
34100
34100
-
-
-
11300
42700
Current
A
0.40×2
0.39×2
0.38×2
3.95 
3.75 
3.65 
-
-
Input power
W
35×2
35×2
35×2
2.510k
2.510k
2.510k
-
-
TOTAL W
-
2.580k
2.580k
2.580k
840
3.700k
Annual consumption
TOTAL kWh *
4
-
-
-
-
1290
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.88 
3.88/A
3.88 
3.93
3.38
Erp
*
6
Pdesign
kW
-
-
-
-
10.0 
-
-
-
SEER
(W/W)
-
-
-
-
6.1 
-
-
-
Annual consumption
kWh
-
-
-
-
574 
-
-
-
Class
-
-
-
-
A++
-
-
-
Power factor
%
-
-
-
96 
96 
96 
-
-
Noise indoor
dB-A (H/M/L) *
7
40/36/32
-
-
-
Power Level dB
56/52/48
-
-
-
Noise outdoor
dB-A (H/L)
-
52/-
-
-
Power Level dB
-
69/-
-
-
H
E
A
T
I
N
G
Capacity
kW
11.2 
11.2 
11.2 
-
-
-
4.1 
14.0 
BTU/h
38200
38200
38200
-
-
-
14000
47800
Current
A
0.40×2
0.39×2
0.38×2
4.35 
4.15
4.00
-
-
Input power
W
35×2
35×2
35×2
2.690k
2.690k
2.690k
-
-
TOTAL W
-
2.760k
2.760k
2.760k
900
4.400k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
4.06 
4.06/A
4.06 
4.56
3.18
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
10.0 
-
-
-
Tbivalent
°C
-
-
-
-
-10 
-
-
-
SCOP
(W/W)
-
-
-
-
4.0 
-
-
-
Annual consumption
kWh
-
-
-
-
3500 
-
-
-
Class
-
-
-
-
A+
-
-
-
Power factor
%
-
-
-
94 
94 
94 
-
-
Noise indoor
dB-A (H/M/L) *
7
40/36/32
-
-
-
Power Level dB
56/52/48
-
-
-
Noise outdoor
dB-A (H/L)
-
52/-
-
-
Power Level dB
-
69/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
0.40/35×2
0.39/35×2
0.38/35×2
9.0 /5.63k
9.0 /5.86k
9.0 /6.02k
-
Starting current(A) / Comp output(W)
-
-
-
4.35/3.0k
4.15/3.0k
4.00/3.0k
-
Network Impedance(ΩMAX.)
-
-
-
Fan motor output (Indoor/Outdoor) W
54
90×2
-
Moisture removal volume
L/h(Pt/h)
3.6
(1.8×2) 
(7.6)
-
-
External static pressure
Pa
-
-
-
Indoor  
Air flow *
7
Cooling
m³/min (ft³/min)
16.0×2/13.5×2/11.0×2 (565)×2/(477)×2/(388)×2
-
-
-
Heating
m³/min (ft³/min)
16.0×2/13.5×2/11.0×2 (565)×2/(477)×2/(388)×2
-
-
-
Outdoor  
Air flow
Cooling
m³/min (ft³/min)
-
110.0 (3885)
-
-
Heating
m³/min (ft³/min)
-
95.0 (3355)
-
-
Refrigerant type / amount g(oz)
-
R410A
3.40k
(119.9)
-
Product dimension
Height mm(inch)
302 
(11-29/32)
1416 
(55-3/4)
-
Width
mm(inch)
1120 
(44-3/32)
940 
(37-1/32)
-
Depth mm(inch)
236 
(9-9/32)
340 
(13-13/32)
-
Product dimension (Panel) H×W×D mm, inch
-
-
-
Packing dimension
Height mm(inch)
282 
(11-1/8)
1556 
-
Width
mm(inch)
1190 
(46-7/8)
1055 
-
Depth
mm(inch)
378 
(14-29/32)
485 
-
Weight
(NET)
kg(lb)
13 
(29)
98
(216)
-
(GROSS)  kg(lb)
16 
(36)
108
(238)
-
Panel (NET)  kg(lb)
-
-
-
Layers limit (actually)
11(12)
1(2)
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)Ø6.35(1/4)   (Gas)Ø12.7(1/2)
(Liquid)Ø9.52(3/8) (Gas)Ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range     m (ft)
5 ~ 75m (16.4 ~ 246.1)
-
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m (0.538)
-
Pipe length for additional gas  m (ft)
30m (98.4)
-
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6  SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season, Other fiche data  
indicates in an attached sheet.
*7 H: High at setting 5 stage (Level 5), M: Middle at setting 5 stage (Level 3), L: Low at setting 5 stage (Level 1)
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   18
19/09/26   17:01:30
1-1-3-19
1
1
Simultaneous (Triple) -Type
1-1.  Unit Specifications
PE1
3. Wall Mounted Type S-50PK2E5B×3 / U-140PE1E8A
INDOOR
MODEL
S-50PK2E5B×3
-
-
PANEL
MODEL
-
-
-
OUTDOOR
MODEL
-
U-140PE1E8A
-
Branch pipe
MODEL
CZ-P3HPC2
Performance test condition
ISO5151  /  EN14511  /  EN12102  /  EN14825
Power supply
Ø, Hz
1Ø 50Hz
3Ø 50Hz
V
220
230
240
380
400
415
Min
Max
C
O
O
L
I
N
G
Capacity
kW
14.0 
14.0 
14.0 
-
-
-
3.3 
15.5 
BTU/h
47800
47800
47800
-
-
-
11300
52900
Current
A
0.40×3
0.39×3
0.38×3
7.10 
6.85 
6.65 
-
-
Input power
W
35×3
35×3
35×3
4.545k
4.545k
4.545k
-
-
TOTAL W
-
4.650k
4.650k
4.650k
840
6.000k
Annual consumption
TOTAL kWh *
4
-
-
-
-
2325
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.01 
3.01/B
3.01 
3.93
2.58
Erp
*
6
Pdesign
kW
-
-
-
-
14.0 
-
-
-
η 
s,c
%
-
-
-
-
231.0 
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
97 
96 
95 
-
-
Noise indoor
dB-A (H/M/L) *
7
40/36/32
-
-
-
Power Level dB
56/52/48
-
-
-
Noise outdoor
dB-A (H/L)
-
54/-
-
-
Power Level dB
-
71/-
-
-
H
E
A
T
I
N
G
Capacity
kW
16.0 
16.0 
16.0 
-
-
-
4.1 
18.0 
BTU/h
54600
54600
54600
-
-
-
14000
61400
Current
A
0.40×3
0.39×3
0.38×3
7.30 
6.95
6.75
-
-
Input power
W
35×3
35×3
35×3
4.665k
4.665k
4.665k
-
-
TOTAL W
-
4.770k
4.770k
4.770k
900
5.900k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.35 
3.35/C
3.35 
4.56
3.05
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
14.0 
-
-
-
Tbivalent
°C
-
-
-
-
-7 
-
-
-
η 
s,h
%
-
-
-
-
138.4 
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
97 
97 
96 
-
-
Noise indoor
dB-A (H/M/L) *
7
40/36/32
-
-
-
Power Level dB
56/52/48
-
-
-
Noise outdoor
dB-A (H/L)
-
55/-
-
-
Power Level dB
-
71/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
0.40/35×3
0.39/35×3
0.38/35×3
11.0/ 6.80k
11.0/7.15k
11.0/7.45k
-
Starting current(A) / Comp output(W)
-
-
-
7.30/3.0k
6.95/3.0k
6.75/3.0k
-
Network Impedance(ΩMAX.)
-
-
-
Fan motor output (Indoor/Outdoor) W
54
90×2
-
Moisture removal volume
L/h(Pt/h)
5.4
(1.8×3)
(11.3)
-
-
External static pressure
Pa
-
-
-
Indoor  
Air flow *
7
Cooling
m³/min (ft³/min)
16.0×3/13.5×3/11.0×3 (565)×3/(477)×3/(388)×3
-
-
-
Heating
m³/min (ft³/min)
16.0×3/13.5×3/11.0×3 (565)×3/(477)×3/(388)×3
-
-
-
Outdoor  
Air flow
Cooling
m³/min (ft³/min)
-
135.0 (4767)
-
-
Heating
m³/min (ft³/min)
-
120.0 (4238)
-
-
Refrigerant type / amount g(oz)
-
R410A  
3.40k
(119.9)
-
Product dimension
Height mm(inch)
302 
(11-29/32)
1416 (55-3/4)
-
Width
mm(inch)
1120 
(44-3/32)
940 (37-1/32)
-
Depth mm(inch)
236 
(9-9/32)
340 (13-13/32)
-
Product dimension (Panel) H×W×D mm, inch
-
-
Packing dimension
Height mm(inch)
282 
(11-1/8)
1556 
-
Width
mm(inch)
1190 
(46-7/8)
1055 
-
Depth
mm(inch)
378 
(14-29/32)
485 
-
Weight
(NET)
kg(lb)
13 
(29)
98
(216)
-
(GROSS)  kg(lb)
16 
(36)
108
(238)
-
Panel (NET)  kg(lb)
-
-
-
Layers limit (actually)
11(12)
1(2)
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)Ø6.35(1/4) (Gas)Ø12.7(1/2)
(Liquid)Ø9.52(3/8) (Gas)Ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range     m (ft)
5 ~ 75m (16.4 ~246.1)
-
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m (0.538)
-
Pipe length for additional gas  m (ft)
20m (65.6)
-
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6 
η 
s,c
 and 
η 
s,h
 classification is at 230V(400V) only in accordance with EN-14825. For heating, 
η 
s,h
 indicates the value of only Average heating season.
*7 H: High at setting 5 stage (Level 5), M: Middle at setting 5 stage (Level 3), L: Low at setting 5 stage (Level 1)
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   19
19/09/26   17:01:30
Page of 127