DOWNLOAD Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B Service Manual ↓ Size: 129.09 MB | Pages: 127 in PDF or view online for FREE

Model
U-50PE2E5A U-100PE1E8A U-100PEY1E8 U-125PE1E8A U-125PEY1E8 U-140PE1E8A U-140PEY1E8 S-100PU2E5B S-125PU2E5B S-140PU2E5B S-71PU2E5B S-100PF1E5B S-125PF1E5B S-140PF1E5B S-71PF1E5B
Pages
127
Size
129.09 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
u-50pe2e5a-u-100pe1e8a-u-100pey1e8-u-125pe1e8a-u-1.pdf
Date

Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B Service Manual ▷ View online

TECHNICAL DATA & SERVICE MANUAL
REFERENCE NO.
SM830274-02
R410A Models
Model No.
Indoor Units
Outdoor Units
Indoor Unit
Outdoor Unit
Wall Mounted
Ceiling
Low Silhouette Ducted
4-Way Cassette
4-Way Cassette 60 x 60
Ducted
Order No. SBPAC1810004CE 
Indoor 
UnitsType
36
45
50
60
71
100
125
140
4-Way Cassette
S-36PU2E5B S-45PU2E5B S-50PU2E5B S-60PU2E5B S-71PU2E5B S-100PU2E5B S-125PU2E5B S-140PU2E5B
S-36PF1E5B S-45PF1E5B S-50PF1E5B S-60PF1E5B S-71PF1E5B S-100PF1E5B S-125PF1E5B S-140PF1E5B
S-36PN1E5B S-45PN1E5B S-50PN1E5B S-60PN1E5B S-71PN1E5B S-100PN1E5B S-125PN1E5B S-140PN1E5B
S-36PT2E5B S-45PT2E5B S-50PT2E5B S-60PT2E5B S-71PT2E5B S-100PT2E5B
S-100PK2E5B
S-125PT2E5B S-140PT2E5B
S-36PK2E5B S-45PK2E5B S-50PK2E5B S-60PK2E5B S-71PK2E5B
Wall Mounted
Low Silhouette 
Ducted
Ducted
S-36PY2E5B S-45PY2E5B S-50PY2E5B
4-Way 
Cassette 60 x 60
Y2
Type
U2
K2
F1
N1
T2 Ceiling
50
36
60
71
100
125
140


U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A
U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8A
U-60PE2E5A
U-50PE2E5A
U-36PE2E5A
Type
PE1
PE2
PEY1
PEY2
Outdoor UnitsType
Single Split (1-phase)
Single Split (1-phase)
Single Split (1-phase)
Single Split (3-phase)
Single Split (1-phase)
Single Split (3-phase)
U-100PEY1E8 U-125PEY1E8
U-60PEY2E5 U-71PEY2E5
U-100PEY1E5 U-125PEY1E5
U-140PEY1E8
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   1
2019/09/24   16:21:13
i
IMPORTANT!
Please Read Before Starting
This air conditioner must be installed by the sales dealer 
or installer.
This information is provided for use only by authorized 
persons.
For safe installation and trouble-free operation, you 
must:
  Carefully read this instruction booklet before beginning.
  Follow each installation or repair step exactly as shown.
  This air conditioner shall be installed in accordance with 
National Wiring Regulations.
  That compliance with national gas regulations shall be 
observed.
  The product meets the technical requirements of 
EN/IEC 61000-3-3.
  Pay close attention to all warning and caution notices 
given in this manual.
 
WARNING
This symbol refers to a hazard or 
unsafe practice which can result in 
severe personal injury or death.
 
CAUTION
This symbol refers to a hazard or 
unsafe practice which can result 
in personal injury or product or 
property damage.
If Necessary, Get Help 
These instructions are all you need for most installation 
sites and maintenance conditions. If you require help for 
a special problem, contact our sales/service outlet or your 
certified dealer for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for 
improper installation or maintenance service, including 
failure to follow the instructions in this document.
 WARNING
 Do not use means to accelerate 
the defrosting process or to clean, 
other than those recommended by 
the manufacturer.
 The appliance shall be stored 
in a room without continuously 
operating ignition sources (for 
example: open flames, an 
operating gas appliance or an 
operating electric heater).
 Do not pierce or burn.
 Be aware that refrigerants may not 
contain an odour.
SPECIAL PRECAUTIONS
 WARNING  When Wiring
WARNING
Risk of Electric Shock
ELECTRICAL SHOCK CAN 
CAUSE SEVERE PERSONAL 
INJURY OR DEATH. ONLY A 
QUALIFIED, EXPERIENCED 
ELECTRICIAN SHOULD 
ATTEMPT TO WIRE THIS 
SYSTEM.
 Do not supply power to the unit until 
all wiring and tubing are completed or 
reconnected and checked.
 Highly dangerous electrical voltages are 
used in this system. Carefully refer to the 
wiring diagram and these instructions 
when wiring. Improper connections 
and inadequate grounding can cause 
accidental injury or death.
 Connect all wiring tightly. Loose wiring 
may cause overheating at connection 
points and a possible fire hazard.
 Provide a power outlet to be used 
exclusively for each unit.
 Provide a power outlet exclusively for 
each unit, and full disconnection means 
having a contact separation by 3 mm 
in all poles must be incorporated in the 
fixed wiring in accordance with the wiring 
rules.
  To prevent possible hazards from 
insulation failure, the unit must be 
grounded.
00_301040_all.indb   2
2018/3/2   10:02:31
 Check that cabling will not be subject 
to wear, corrosion, excessive pressure, 
vibration, sharp edges or any other 
adverse environmental effects.
  The check shall also take into account 
the effects of aging or continual vibration 
from sources such as compressors or 
fans.
  This equipment is strongly 
recommended to be installed with 
Earth Leakage Circuit Breaker (ELCB) 
or Residual Current Device (RCD). 
Otherwise, it may cause electrical 
shock and fire in case of equipment 
breakdown or insulation breakdown.
When Transporting
• It may need two or more people to carry
out the installation work.
• Be careful when picking up and moving
the indoor and outdoor units. Get a 
partner to help, and bend your knees 
when lifting to reduce strain on your 
back. Sharp edges or thin aluminum 
fins on the air conditioner can cut your 
fingers.
When storing…
 WARNING
• The appliance shall be stored
in a well-ventilated area where 
the room size corresponds to 
the room area as specified for 
operation.
• The appliance shall be stored
in a room without continuously 
operating open flames (for 
example: an operating gas 
appliance) and ignition sources 
(for example: an operating 
electric heater).
• The appliance shall be stored so as
to prevent mechanical damage from 
occurring.
When Installing…
• Select an installation location which is
rigid and strong enough to support or 
hold the unit, and select a location for 
easy maintenance.
• In cases that require mechanical
ventilation, ventilation openings shall be 
kept clear of obstruction.
…In a Room
Properly insulate any tubing run inside 
a room to prevent “sweating” that can 
cause dripping and water damage to 
walls and floors.
 CAUTION
Keep the fire alarm and 
the air outlet at least  
1.5 m away from the 
unit.
…In Moist or Uneven Locations
Use a raised concrete pad or concrete 
blocks to provide a solid, level foundation 
for the outdoor unit. This prevents water 
damage and abnormal vibration.
…In an Area with High Winds
Securely anchor the outdoor unit down 
with bolts and a metal frame. Provide a 
suitable air baffle.
…In a Snowy Area (for Heat Pump-
type Systems)
Install the outdoor unit on a raised 
platform that is higher than drifting snow. 
Provide snow vents.
(Type K2) 
...At least 1.8m 
Indoor unit of this air conditioner shall be 
installed in a height of at least 1.8 m.
…In laundry rooms
Do not install in laundry rooms. Indoor 
unit is not drip proof.
When Connecting Refrigerant 
Tubing
Pay particular attention to refrigerant 
leakages.
(Type Y2)
(Type U2, Type T2, Type F1, Type N1)
...At least 2.5m
Indoor unit of this air conditioner shall be 
installed in a height of at least 2.5 m.
…At least 2.2m
Indoor unit of this air conditioner shall be 
installed in a height of at least 2.2m.
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   1
2019/09/24   16:21:15
ii
IMPORTANT!
Please Read Before Starting
This air conditioner must be installed by the sales dealer 
or installer.
This information is provided for use only by authorized 
persons.
For safe installation and trouble-free operation, you 
must:
  Carefully read this instruction booklet before beginning.
  Follow each installation or repair step exactly as shown.
  This air conditioner shall be installed in accordance with 
National Wiring Regulations.
  That compliance with national gas regulations shall be 
observed.
  The product meets the technical requirements of 
EN/IEC 61000-3-3.
  Pay close attention to all warning and caution notices 
given in this manual.
 
WARNING
This symbol refers to a hazard or 
unsafe practice which can result in 
severe personal injury or death.
 
CAUTION
This symbol refers to a hazard or 
unsafe practice which can result 
in personal injury or product or 
property damage.
If Necessary, Get Help 
These instructions are all you need for most installation 
sites and maintenance conditions. If you require help for 
a special problem, contact our sales/service outlet or your 
certified dealer for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for 
improper installation or maintenance service, including 
failure to follow the instructions in this document.
 WARNING
 Do not use means to accelerate 
the defrosting process or to clean, 
other than those recommended by 
the manufacturer.
 The appliance shall be stored 
in a room without continuously 
operating ignition sources (for 
example: open flames, an 
operating gas appliance or an 
operating electric heater).
 Do not pierce or burn.
 Be aware that refrigerants may not 
contain an odour.
SPECIAL PRECAUTIONS
 WARNING  When Wiring
WARNING
Risk of Electric Shock
ELECTRICAL SHOCK CAN 
CAUSE SEVERE PERSONAL 
INJURY OR DEATH. ONLY A 
QUALIFIED, EXPERIENCED 
ELECTRICIAN SHOULD 
ATTEMPT TO WIRE THIS 
SYSTEM.
 Do not supply power to the unit until 
all wiring and tubing are completed or 
reconnected and checked.
 Highly dangerous electrical voltages are 
used in this system. Carefully refer to the 
wiring diagram and these instructions 
when wiring. Improper connections 
and inadequate grounding can cause 
accidental injury or death.
 Connect all wiring tightly. Loose wiring 
may cause overheating at connection 
points and a possible fire hazard.
 Provide a power outlet to be used 
exclusively for each unit.
 Provide a power outlet exclusively for 
each unit, and full disconnection means 
having a contact separation by 3 mm 
in all poles must be incorporated in the 
fixed wiring in accordance with the wiring 
rules.
  To prevent possible hazards from 
insulation failure, the unit must be 
grounded.
00_301040_all.indb   2
2018/3/2   10:02:31
 Check that cabling will not be subject 
to wear, corrosion, excessive pressure, 
vibration, sharp edges or any other 
adverse environmental effects.
  The check shall also take into account 
the effects of aging or continual vibration 
from sources such as compressors or 
fans.
  This equipment is strongly 
recommended to be installed with 
Earth Leakage Circuit Breaker (ELCB) 
or Residual Current Device (RCD). 
Otherwise, it may cause electrical 
shock and fire in case of equipment 
breakdown or insulation breakdown.
When Transporting
• It may need two or more people to carry
out the installation work.
• Be careful when picking up and moving
the indoor and outdoor units. Get a 
partner to help, and bend your knees 
when lifting to reduce strain on your 
back. Sharp edges or thin aluminum 
fins on the air conditioner can cut your 
fingers.
When storing…
 WARNING
• The appliance shall be stored
in a well-ventilated area where 
the room size corresponds to 
the room area as specified for 
operation.
• The appliance shall be stored
in a room without continuously 
operating open flames (for 
example: an operating gas 
appliance) and ignition sources 
(for example: an operating 
electric heater).
• The appliance shall be stored so as
to prevent mechanical damage from 
occurring.
When Installing…
• Select an installation location which is
rigid and strong enough to support or 
hold the unit, and select a location for 
easy maintenance.
• In cases that require mechanical
ventilation, ventilation openings shall be 
kept clear of obstruction.
…In a Room
Properly insulate any tubing run inside 
a room to prevent “sweating” that can 
cause dripping and water damage to 
walls and floors.
 CAUTION
Keep the fire alarm and 
the air outlet at least  
1.5 m away from the 
unit.
…In Moist or Uneven Locations
Use a raised concrete pad or concrete 
blocks to provide a solid, level foundation 
for the outdoor unit. This prevents water 
damage and abnormal vibration.
…In an Area with High Winds
Securely anchor the outdoor unit down 
with bolts and a metal frame. Provide a 
suitable air baffle.
…In a Snowy Area (for Heat Pump-
type Systems)
Install the outdoor unit on a raised 
platform that is higher than drifting snow. 
Provide snow vents.
(Type K2) 
...At least 1.8m 
Indoor unit of this air conditioner shall be 
installed in a height of at least 1.8 m.
…In laundry rooms
Do not install in laundry rooms. Indoor 
unit is not drip proof.
When Connecting Refrigerant 
Tubing
Pay particular attention to refrigerant 
leakages.
(Type Y2)
(Type U2, Type T2, Type F1, Type N1)
...At least 2.5m
Indoor unit of this air conditioner shall be 
installed in a height of at least 2.5 m.
…At least 2.2m
Indoor unit of this air conditioner shall be 
installed in a height of at least 2.2m.
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   2
2019/09/24   16:21:15
iii
 WARNING
• When performing piping work, do 
not mix air except for specified 
refrigerant (R410A) in refrigeration  
cycle. It causes capacity down, and  
risk of explosion and injury due to  
high tension inside the refrigerant 
cycle.
• If the refrigerant comes in contact
with a flame, it produces a toxic 
gas.
• Do not add or replace refrigerant
other than specified type. It may 
cause product damage, burst and 
injury, etc.
• Ventilate the room immediately, in the
event that is refrigerant gas leaks during 
the installation. Be careful not to allow 
contact of the refrigerant gas with a 
flame as this will cause the generation 
of toxic gas.
• Keep all tubing runs as short as
possible.
• Use the flare method for connecting
tubing.
• Apply refrigerant lubricant to the
matching surfaces of the flare and union 
tubes before connecting them, then 
tighten the nut with a torque wrench for 
a leak-free connection.
• Check carefully for leaks before starting
the test run.
• Do not leak refrigerant while piping work
for an installation or re-installation, and 
while repairing refrigeration parts.  
Handle liquid refrigerant carefully as it 
may cause frostbite.
• Under no circumstances shall potential
sources of ignition be used in the 
searching or detection of refrigerant 
leaks.
• A halide torch (or any other detector
using a naked flame) shall not be used.
• Electronic leak detectors may be used
to detect refrigerant leaks but, the 
sensitivity may not be adequate, or 
may need re-calibration. (Detection 
equipment shall be calibrated in a 
refrigerant-free area.)
• Ensure that the detector is not a
potential source of ignition and is 
suitable for the refrigerant used.
• Leak detection fluids are suitable for
use with most refrigerants but the use of 
detergents containing chlorine shall be 
avoided as the chlorine may react with 
the refrigerant and corrode the copper 
pipe-work.
• If a leak is suspected, all naked flames
shall be removed/extinguished.
• If a leakage of refrigerant is found which
requires brazing, all of the refrigerant 
shall be recovered from the system, or 
isolated (by means of shut off valves) 
in a part of the system remote from the 
leak. Oxygen free nitrogen (OFN) shall 
then be purged through the system both 
before and during the brazing process.
When Servicing
• Contact to the sales dealer or service
dealer for a repair.
• Be sure to turn off the power before
servicing.
• Turn the power OFF at the main
power box (mains), wait at least 10 
minutes until it is discharged, then 
open the unit to check or repair 
electrical parts and wiring.
• Keep your fingers and clothing away
from any moving parts.
• Clean up the site after you finish,
remembering to check that no metal 
scraps or bits of wiring have been left 
inside the unit.
00_301040_all.indb   4
2018/3/2   10:02:31
 WARNING
• This product must not be
modified or disassembled under 
any circumstances. Modified or 
disassembled unit may cause fire, 
electric shock or injury.
• Do not clean inside the indoor and
outdoor units by users. Engage 
authorized dealer or specialist for 
cleaning.
• In case of malfunction of this
appliance, do not repair by 
yourself. Contact to the sales 
dealer or service dealer for a 
repair and disposal.
 CAUTION
• Ventilate any enclosed areas
when installing or testing the 
refrigeration system. Leaked 
refrigerant gas, on contact 
with fire or heat, can produce 
dangerously toxic gas.
• Confirm after installation that
no refrigerant gas is leaking. If 
the gas comes in contact with a 
burning stove, gas water heater, 
electric room heater or other 
heat source, it can cause the 
generation of toxic gas.
Others
When disposal of the product, comply 
with national regulations.
 WARNING
• Do not sit or step on the 
unit. You may fall down 
accidentally.
 CAUTION
• Do not touch the air inlet or 
the sharp aluminum fins of  
the outdoor unit. You may get  
injured.
• Do not stick any object into 
the FAN CASE.  
You may be injured and the  
unit may be damaged.
00_301040_all.indb   5
2018/3/2   10:02:32
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   3
2019/09/24   16:21:16
Page of 127
Display

Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B Service Manual ▷ Download

  • DOWNLOAD Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B Service Manual ↓ Size: 129.09 MB | Pages: 127 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B Air Conditioner. Information contained in Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.