DOWNLOAD Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B Service Manual ↓ Size: 129.09 MB | Pages: 127 in PDF or view online for FREE

Model
U-50PE2E5A U-100PE1E8A U-100PEY1E8 U-125PE1E8A U-125PEY1E8 U-140PE1E8A U-140PEY1E8 S-100PU2E5B S-125PU2E5B S-140PU2E5B S-71PU2E5B S-100PF1E5B S-125PF1E5B S-140PF1E5B S-71PF1E5B
Pages
127
Size
129.09 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
u-50pe2e5a-u-100pe1e8a-u-100pey1e8-u-125pe1e8a-u-1.pdf
Date

Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B Service Manual ▷ View online

1-1-4-9
1
1
Single -Type
1-1.  Unit Specifications
PE2
4. Low Silhouette Ducted Type S-60PF1E5B / U-60PE2E5A
*1
: In case it is necessary to indicate the air flow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:  If the EUROVENT Certified models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230 V shall 
be used.
*3
: Network Impedance shall be applicable for EUROPE and CHINA models.
*4
: The annual consumption is calculated by multiplying the input power at 230V (400V) by an average of 500 hours per year in cooling mode.
*5
: EER and COP classification is at 230V (400 V) only in accordance with EU directive 2002/31/EC.
*6
:  SEER and SCOP classification is at 230V (400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season, Other fiche data 
indicates in an attached sheet.
INDOOR
MODEL
S-60PF1E5B
-
-
OUTDOOR
MODEL
-
U-60PE2E5A
-
Branch pipe
MODEL
-
Performance test condition
ISO13253  /  EN14511  /   EN12102  /  EN14825
Power supply
Ø, Hz
1ø 50Hz
1ø 50Hz
V
220
230
240
220
230
240
Min
Max
C
O
O
L
I
N
G
Capacity
kW
6.00
6.00
6.00
-
-
-
2.0 
7.1 
BTU/h
20500
20500
20500
-
-
-
6800 
24200 
Current
A
0.91
0.89
0.87
7.70 
7.40 
7.10 
-
-
Input power
W
120
120
120
1.530k
1.530k
1.530k
-
-
TOTAL W
-
1.650k
1.650k
1.650k
335
2.350k
Annual consumption
TOTAL kWh *
4
-
-
825
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.64 
3.64/A
3.64 
5.97
3.02
Erp
*
6
Pdesign
kW
-
-
-
-
6.0 
-
-
-
SEER
(W/W)
-
-
-
-
6.1 
-
-
-
Annual consumption
kWh
-
-
-
-
344 
-
-
-
Class
-
-
-
-
A++
-
-
-
Power factor
%
-
-
-
90 
90 
90 
-
-
Noise indoor
dB-A (H/M/L)
35/32/26
-
-
-
Power Level dB
57/54/48
-
-
-
Noise outdoor
dB-A (H/L)
-
46/-
-
-
Power Level dB
-
65/-
-
-
H
E
A
T
I
N
G
Capacity
kW
7.00
7.00
7.00
-
-
-
1.8 
8.0 
BTU/h
23900
23900
23900
-
-
-
6100 
27300 
Current
A
0.91
0.89
0.87
8.25 
7.85 
7.55
-
-
Input power
W
120
120
120
1.630k
1.630k
1.630k
-
-
TOTAL W
-
1.750k
1.750k
1.750k
285
2.100k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
4.00 
4.00/A
4.00 
6.32
3.81
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
6.0 
-
-
-
Tbivalent
°C
-
-
-
-
-8
-
-
-
SCOP
(W/W)
-
-
-
-
4.0 
-
-
-
Annual consumption
kWh
-
-
-
-
2100
-
-
-
Class
-
-
-
-
A+
-
-
-
Power factor
%
-
-
-
90 
90 
90 
-
-
Noise indoor
dB-A (H/M/L)
35/32/26
-
-
-
Power Level dB
57/54/48
-
-
-
Noise outdoor
dB-A (H/L)
-
49/-
-
-
Power Level dB
-
69/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
1.26/160
1.20/160
1.15/160
16.5/3.27k
16.5/3.42k
16.5/3.57k
-
Starting current(A) / Comp output(W)
-
-
-
8.25/1.7k
7.85/1.7k
7.55/1.7k
-
Network Impedance(ΩMAX.)
-
-
-
Fan motor output (Indoor/Outdoor) W
120
60
-
Moisture removal volume
L/h(Pt/h)
3.4
(7.1)
-
-
External static pressure
Pa
70 (MIN10 - MAX150)
-
-
Indoor  
Air flow  
Cooling
m³/min (ft³/min)
21.0 / 19.0 / 15.0 (742) / (671) / (530)
-
-
-
Heating
m³/min (ft³/min)
21.0 / 19.0 / 15.0 (742) / (671) / (530)
-
-
-
Outdoor  
Air flow
Cooling
m³/min (ft³/min)
-
38.0
(1342)
-
-
Heating
m³/min (ft³/min)
-
41.0
(1448)
-
-
Refrigerant type / amount g(oz)
-
R410A
1.95k
(68.8)
-
Product dimension
Height mm(inch)
290  
(11-13/32)
619  
(24-3/8)
-
Width
mm(inch)
1000  
(39-3/8)
799  
(31-29/64)
-
Depth
mm(inch)
700  
(27-9/16)
299  
(11-49/64)
-
Product dimension (Panel) H×W×D mm, inch
-
-
-
Packing dimension
Height mm(inch)
355
(13-31/32)
688 
-
Width
mm(inch)
1214
(47-13/16)
931 
-
Depth
mm(inch)
850
(33-15/32)
422 
-
Weight
(NET)
kg(lb)
33   
(73)
40   
(88)
-
(GROSS)  kg(lb)
41   
(91)
45   
(99)
-
Panel (NET)  kg(lb)
-
-
-
Layers limit (actually)
9 (10) 
5 (6) 
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range     m (ft)
3 ~ 40m
(9.8 ~ 131.2)
-
Indoor unit & Outdoor unit height difference m (ft)
15m (OD located lower) / 30m (OD located higher)
(49.2/98.4)
-
Add gas amount g/m (oz/ft)
40g/m 
(0.430)
-
Pipe length for additional gas  m (ft)
30m
(98.4)
-
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   9
19/09/26   17:01:35
1-1-4-10
1
1
Simultaneous (Twin) -Type
1-1.  Unit Specifications
PE1
4. Low Silhouette Ducted Type S-60PF1E5B×2 / U-125PE1E5A
INDOOR
MODEL
S-60PF1E5B×2
-
-
OUTDOOR
MODEL
-
U-125PE1E5A
-
Branch pipe
MODEL
CZ-P155BK1
Performance test condition
ISO13253  /  EN14511  /  EN12102  /  EN14825
Power supply
Ø, Hz
1ø 50Hz
1ø 50Hz
V
220
230
240
220
230
240
Min
Max
C
O
O
L
I
N
G
Capacity
kW
12.5
12.5
12.5
-
-
-
3.3
14.0
BTU/h
42700
42700
42700
-
-
-
11300
47800
Current
A
0.91×2
0.89×2
0.87×2
16.6
15.9
15.3
-
-
Input power
W
120×2
120×2
120×2
3.355k
3.355k
3.355k
-
-
TOTAL W
-
3.595k
3.595k
3.595k
840
4.600k
Annual consumption
TOTAL kWh *
4
-
-
1797.5
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.48
3.48 / A
3.48
3.93
3.04
Erp
*
6
Pdesign
kW
-
-
-
-
12.5
-
-
-
η 
s,c
%
-
-
-
-
234.1
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
92
92
91
-
-
Noise indoor
dB-A (H/M/L)
35/32/26
-
-
-
-
-
Power Level dB
57/54/48
-
-
-
-
-
Noise outdoor
dB-A (H/L)
-
53/-
-
-
Power Level dB
-
70/-
-
-
H
E
A
T
I
N
G
Capacity
kW
14.0
14.0
14.0
-
-
-
4.1
16.0
BTU/h
47800
47800
47800
-
-
-
14000
54600
Current
A
0.91×2
0.89×2
0.87×2
16.3
15.8
15.1
-
-
Input power
W
120×2
120×2
120×2
3.270k
3.270k
3.270k
-
-
TOTAL W
-
3.510k
3.510k
3.510k
900
5.200k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.99
3.99 / A
3.99
4.56
3.08
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
12.5
-
-
-
Tbivalent
°C
-
-
-
-
-9
-
-
-
η 
s,h
%
-
-
-
-
146.6
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
91
90
90
-
-
Noise indoor
dB-A (H/M/L)
35/32/26
-
-
-
Power Level dB
57/54/48
-
-
-
Noise outdoor
dB-A (H/L)
-
53/-
-
-
Power Level dB
-
70/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
1.26×2/160×2 1.20×2/160×2 1.15×2/160×2 28.0/6.000k 28.0/6.200k 28.0/6.400k
-
Starting current(A) / Comp output(W)
-
-
-
16.6/3.0k
15.9/3.0k
15.3/3.0k
-
Network Impedance(ΩMAX.)
-
-
-
Fan motor output (Indoor/Outdoor) W
120
90x2
-
Moisture removal volume
L/h(Pt/h)
7.9
(3.9×2)
(16.6)
-
-
External static pressure
Pa
70 (MIN10 - MAX150)
-
-
Indoor  
Air flow 
Cooling
m³/min (ft³/min)
21.0×2/19.0×2/15.0×2 (742)×2/(671)×2/(530)×2
-
-
-
Heating
m³/min (ft³/min)
21.0×2/19.0×2/15.0×2 (742)×2/(671)×2/(530)×2
-
-
-
Outdoor  
Air flow
Cooling
m³/min (ft³/min)
-
130.0
(4591)
-
-
Heating
m³/min (ft³/min)
-
110.0
(3885)
-
-
Refrigerant type / amount g(oz)
-
R410A
3.40k
(119.9)
-
Product dimension
Height mm(inch)
290  (11-13/32)
1416  (55-3/4)
-
Width
mm(inch)
1000  (39-3/8)
940  (37-1/32)
-
Depth
mm(inch)
700  (27-9/16)
340  (13-13/32)
-
Packing dimension
Height mm(inch)
355
1556
-
Width
mm(inch)
1214
1055
-
Depth
mm(inch)
850
485
-
Weight
(NET)
kg(lb)
33   (73)
98   (216)
-
(GROSS)  kg(lb)
41   (91)
108   (238)
-
Layers limit (actually)
9 (10) 
1 (2) 
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range     m (ft)
5 ~ 75m
(16.4 ~ 246.1)
-
Indoor unit & Outdoor unit height difference m (ft)
15m (OD located lower) / 30m (OD located higher)
(49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m 
(0.538)
-
Pipe length for additional gas  m (ft)
30m
(98.4)
-
*1
: In case it is necessary to indicate the air flow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:  If the EUROVENT Certified models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 
230 V shall be used.
*3
: Network Impedance shall be applicable for EUROPE and CHINA models.
*4
: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5
: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6
:  η 
s,c
 and 
η 
s,h
 classification is at 230V(400V) only in accordance with EN-14825. For heating, 
η 
s,h
 indicates the value of only Average heating season.
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   10
19/09/26   17:01:35
1-1-4-11
1
1
Single -Type
1-1.  Unit Specifications
PE1
4. Low Silhouette Ducted Type S-71PF1E5B / U-71PE1E5A
INDOOR
MODEL
S-71PF1E5B
-
-
OUTDOOR
MODEL
-
U-71PE1E5A
-
Branch pipe
MODEL
-
Performance test condition
ISO13253  /  EN14511  /  EN14825  /   EN12102
Power supply
Ø, Hz
1ø 50Hz
1ø 50Hz
V
220
230
240
220
230
240
Min
Max
C
O
O
L
I
N
G
Capacity
kW
7.10
7.10
7.10
-
-
-
2.5
8.0
BTU/h
24200
24200
24200
-
-
-
8500
27300
Current
A
0.91
0.89
0.87
8.90
8.60
8.30
-
-
Input power
W
120
120
120
1.730k
1.730k
1.730k
-
-
TOTAL W
-
1.850k
1.850k
1.850k
530
2.650k
Annual consumption
TOTAL kWh *
4
-
-
925
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.84 / A
3.84 / A
3.84 / A
4.72
3.02
Erp
*
6
Pdesign
kW
-
-
-
-
7.1
-
-
-
SEER
(W/W)
-
-
-
-
6.4
-
-
-
Annual consumption
kWh
-
-
-
-
388
-
-
-
Class
-
-
-
-
A++
-
-
-
Power factor
%
-
-
-
94
94
93
-
-
Noise indoor
dB-A (H/M/L)
35/32/26
-
-
-
Power Level dB
57/54/48
-
-
-
Noise outdoor
dB-A (H/L)
-
48
-
-
Power Level dB
-
65
-
-
H
E
A
T
I
N
G
Capacity
kW
8.00
8.00
8.00
-
-
-
2.0
9.0
BTU/h
27300
27300
27300
-
-
-
6800
30700
Current
A
0.91
0.89
0.87
9.90
9.50
9.20
-
-
Input power
W
120
120
120
1.960k
1.960k
1.960k
-
-
TOTAL W
-
2.080k
2.080k
2.080k
480
2.900k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.85 / A
3.85 / A
3.85 / A
4.17
3.10
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
7.1
-
-
-
Tbivalent
°C
-
-
-
-
-9
-
-
-
SCOP
(W/W)
-
-
-
-
4.0
-
-
-
Annual consumption
kWh
-
-
-
-
2485
-
-
-
Class
-
-
-
-
A+
-
-
-
Power factor
%
-
-
-
96
95
94
-
-
Noise indoor
dB-A (H/M/L)
35/32/26
-
-
-
Power Level dB
57/54/48
-
-
-
Noise outdoor
dB-A (H/L)
-
50
-
-
Power Level dB
-
67
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
1.26/160
1.20/160
1.15/160
18.0/3.800k 18.0/3.930k 18.0/4.060k
-
Starting current(A) / Comp output(W)
-
-
-
9.90/2.000k 9.50/2.000k 9.20/2.000k
-
Network Impedance(ΩMAX.)
-
-
-
Fan motor output (Indoor/Outdoor) W
120
90
-
Moisture removal volume
L/h(Pt/h)
4.2
(8.8)
-
-
External static pressure
Pa
70 (MIN10 - MAX150)
-
-
Indoor  
Air flow 
Cooling
m³/min (ft³/min)
21.0/19.0/15.0 (742)/(671)/(530)
-
-
-
Heating
m³/min (ft³/min)
21.0/19.0/15.0 (742)/(671)/(530)
-
-
-
Outdoor  
Air flow
Cooling
m³/min (ft³/min)
-
60.0
(2119)
-
-
Heating
m³/min (ft³/min)
-
60.0
(2119)
-
-
Refrigerant type / amount g(oz)
-
R410A
2.35k
(82.9)
-
Product dimension
Height mm(inch)
290  (11-13/32)
996  (39-7/32)
-
Width
mm(inch)
1000  (39-3/8)
940  (37-1/32)
-
Depth
mm(inch)
700  (27-9/16)
340  (13-13/32)
-
Packing dimension
Height mm(inch)
355
1136
-
Width
mm(inch)
1214
1055
-
Depth
mm(inch)
850
485
-
Weight
(NET)
kg(lb)
33   (73)
69   (152)
-
(GROSS)  kg(lb)
41   (91)
77   (170)
-
Layers limit (actually)
9 (10) 
2 (3) 
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range     m (ft)
5 ~ 50m
(16.4 ~ 164.0)
-
Indoor unit & Outdoor unit height difference m (ft)
15m (OD located lower) / 30m (OD located higher)
(49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m 
(0.538)
-
Pipe length for additional gas  m (ft)
30m
(98.4)
-
*1
: In case it is necessary to indicate the air flow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:  If the EUROVENT Certified models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 
230 V shall be used.
*3
: Network Impedance shall be applicable for EUROPE and CHINA models.
*4
: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5
: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6
:  SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season, 
Other fiche data indicates in an attached sheet.
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   11
19/09/26   17:01:35
1-1-4-12
1
1
Simultaneous (Twin) -Type
1-1.  Unit Specifications
PE1
4. Low Silhouette Ducted Type S-71PF1E5B×2 / U-140PE1E5A
INDOOR
MODEL
S-71PF1E5B×2
-
-
OUTDOOR
MODEL
-
U-140PE1E5A
-
Branch pipe
MODEL
CZ-P155BK1
Performance test condition
ISO13253  /  EN14511  /  EN12102  /  EN14825
Power supply
Ø, Hz
1ø 50Hz
1ø 50Hz
V
220
230
240
220
230
240
Min
Max
C
O
O
L
I
N
G
Capacity
kW
14.0
14.0
14.0
-
-
-
3.3
15.5
BTU/h
47800
47800
47800
-
-
-
11300
52900
Current
A
0.91×2
0.89×2
0.87×2
20.1
19.3
18.6
-
-
Input power
W
120×2
120×2
120×2
4.085k
4.085k
4.085k
-
-
TOTAL W
-
4.325k
4.325k
4.325k
840
6.000k
Annual consumption
TOTAL kWh *
4
-
-
2162.5
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.24
3.24 / A
3.24
3.93
2.58
Erp
*
6
Pdesign
kW
-
-
-
-
14.0
-
-
-
η 
s,c
%
-
-
-
-
226.3
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
93
92
92
-
-
Noise indoor
dB-A (H/M/L)
35/32/26
-
-
-
-
-
Power Level dB
57/54/48
-
-
-
-
-
Noise outdoor
dB-A (H/L)
-
54/-
-
-
Power Level dB
-
71/-
-
-
H
E
A
T
I
N
G
Capacity
kW
16.0
16.0
16.0
-
-
-
4.1
18.0
BTU/h
54600
54600
54600
-
-
-
14000
61400
Current
A
0.91×2
0.89×2
0.87×2
19.9
19.1
18.4
-
-
Input power
W
120×2
120×2
120×2
4.215k
4.215k
4.215k
-
-
TOTAL W
-
4.455k
4.455k
4.455k
900
5.900k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.59
3.59 / A
3.59
4.56
3.05
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
14.0
-
-
-
Tbivalent
°C
-
-
-
-
-7
-
-
-
η 
s,h
%
-
-
-
-
143.0
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
96
96
95
-
-
Noise indoor
dB-A (H/M/L)
35/32/26
-
-
-
Power Level dB
57/54/48
-
-
-
Noise outdoor
dB-A (H/L)
-
55/-
-
-
Power Level dB
-
71/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
1.26×2/160×2 1.20×2/160×2 1.15×2/160×2 30.0/6.450k 30.0/6.650k 30.0/6.850k
-
Starting current(A) / Comp output(W)
-
-
-
20.1/3.0k
19.3/3.0k
18.6/3.0k
-
Network Impedance(ΩMAX.)
-
-
-
Fan motor output (Indoor/Outdoor) W
120
90x2
-
Moisture removal volume
L/h(Pt/h)
9.0
(4.5×2)
(18.9)
-
-
External static pressure
Pa
70 (MIN10 - MAX150)
-
-
Indoor  
Air flow 
Cooling
m³/min (ft³/min)
21.0×2/19.0×2/15.0×2 (742)×2/(671)×2/(530)×2
-
-
-
Heating
m³/min (ft³/min)
21.0×2/19.0×2/15.0×2 (742)×2/(671)×2/(530)×2
-
-
-
Outdoor  
Air flow
Cooling
m³/min (ft³/min)
-
135.0
(4767)
-
-
Heating
m³/min (ft³/min)
-
120.0
(4238)
-
-
Refrigerant type / amount g(oz)
-
R410A
3.40k
(119.9)
-
Product dimension
Height mm(inch)
290  (11-13/32)
1416  (55-3/4)
-
Width
mm(inch)
1000  (39-3/8)
940  (37-1/32)
-
Depth
mm(inch)
700  (27-9/16)
340  (13-13/32)
-
Packing dimension
Height mm(inch)
355
1556
-
Width
mm(inch)
1214
1055
-
Depth
mm(inch)
850
485
-
Weight
(NET)
kg(lb)
33   (73)
98   (216)
-
(GROSS)  kg(lb)
41   (91)
108   (238)
-
Layers limit (actually)
9 (10) 
1 (2) 
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range     m (ft)
5 ~ 75m
(16.4 ~ 246.1)
-
Indoor unit & Outdoor unit height difference m (ft)
15m (OD located lower) / 30m (OD located higher)
(49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m 
(0.538)
-
Pipe length for additional gas  m (ft)
30m
(98.4)
-
*1
: In case it is necessary to indicate the air flow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:  If the EUROVENT Certified models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 
230 V shall be used.
*3
: Network Impedance shall be applicable for EUROPE and CHINA models.
*4
: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5
: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6
:  η 
s,c
 and 
η 
s,h
 classification is at 230V(400V) only in accordance with EN-14825. For heating, 
η 
s,h
 indicates the value of only Average heating season.
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   12
19/09/26   17:01:36
Page of 127
Display

Click on the first or last page to see other U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B service manuals if exist.