1-1. Unit Specifications
PE1
5. Ducted Type S-36PN1E5B×2 / U-71PE1E5A
INDOOR
MODEL
S-36PN1E5B×2
-
-
PANEL
MODEL
-
-
-
OUTDOOR
MODEL
-
U-71PE1E5A
-
Branch pipe
MODEL
-
Performance test condition
ISO13253 / EN14511 / EN14825 / EN12102
Power supply
Ø, Hz
1ø 50Hz
1ø 50Hz
V
220
230
240
220
230
240
Min
Max
C
O
O
L
I
N
G
Capacity
kW
7.1
7.1
7.1
-
-
-
2.5
8.0
BTU/h
24200
24200
24200
-
-
-
8500
27300
Current
A
0.42×2
0.43×2
0.44×2
9.50
9.20
8.95
-
-
Input power
W
90×2
95×2
100×2
1.970k
1.960k
1.950k
-
-
TOTAL W
-
2.150k
2.150k
2.150k
610
2.790k
Annual consumption
TOTAL kWh *
4
-
-
1075
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.30
3.30/A
3.30
4.10
2.87
Erp
*
6
Pdesign
kW
-
-
-
-
7.1
-
-
-
SEER
(W/W)
-
-
-
-
5.3
-
-
-
Annual consumption
kWh
-
-
-
-
467
-
-
-
Class
-
-
-
-
A
-
-
-
Power factor
%
-
-
-
94
93
91
-
-
Noise indoor
dB-A (H/M/L)
35/33/30
-
-
-
Power Level dB
57/55/52
-
-
-
Noise outdoor
dB-A (H/L)
-
48/-
-
-
Power Level dB
-
65/-
-
-
H
E
A
T
I
N
G
Capacity
kW
8.00
8.00
8.00
-
-
-
2.0
9.0
BTU/h
27300
27300
27300
-
-
-
6800
30700
Current
A
0.42×2
0.43×2
0.44×2
9.95
9.65
9.40
-
-
Input power
W
90×2
95×2
100×2
2.080k
2.070k
2.060k
-
-
TOTAL W
-
2.260k
2.260k
2.260k
500
2.960k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.54
3.54/B
3.54
4.00
3.04
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
6.2
-
-
-
Tbivalent
°C
-
-
-
-
-9
-
-
-
SCOP
(W/W)
-
-
-
-
3.8
-
-
-
Annual consumption
kWh
-
-
-
-
2282
-
-
-
elbu(-10°C)
kW
-
-
-
-
0.25
-
-
-
Class
-
-
-
-
A
-
-
-
Power factor
%
-
-
-
95
93
91
-
-
Noise indoor
dB-A (H/M/L)
35/33/30
-
-
-
Power Level dB
57/55/52
-
-
-
Noise outdoor
dB-A (H/L)
-
50/-
-
-
Power Level dB
-
67/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
0.60×2/130×2 0.62×2/140×2 0.63×2/150×2 18.0/3.800k
18.0/3.930k
18.0/4.060k
-
Starting current(A)/Comp output(W)
-
-
-
9.95/2.0k
9.65/2.0k
9.40/2.0k
-
Network Impedance(ΩMAX.)
-
-
Fan motor output (Indoor/Outdoor) W
60×2
90
-
Moisture removal volume
L/h(Pt/h)
4.2
(2.1×2)
(8.8)
-
-
External static pressure
Pa
25 (MAX80)
-
-
Indoor
Air flow
Cooling
m³/min (ft³/min)
14.0×2/12.0×2/10.0×2 (494)×2/(424)×2/(353)×2
-
-
-
Heating
m³/min (ft³/min)
14.0×2/12.0×2/10.0×2 (494)×2/(424)×2/(353)×2
-
-
-
Outdoor
Air flow
Cooling
m³/min (ft³/min)
-
60.0
(2119)
-
-
Heating
m³/min (ft³/min)
-
60.0
(2119)
-
-
Refrigerant type / amount g(oz)
-
R410A
2.35k
(82.9)
-
Product dimension
Height mm(inch)
250 (9-27/32)
996 (39-7/32)
-
Width
mm(inch)
780 [+100] (30-45/64 [+3-15/16])
940 (37-1/32)
-
Depth
mm(inch)
650 (25-19/32)
340 (13-13/32)
-
Product dimension (Panel) H×W×D mm, inch
-
-
-
Packing dimension
Height mm(inch)
338 (13-5/16)
1136
-
Width
mm(inch)
991 (39-1/64)
1055
-
Depth
mm(inch)
761 (29-61/64)
485
-
Weight
(NET)
kg(lb)
29 (64)
69 (152)
-
(GROSS) kg(lb)
34 (75)
77 (170)
-
Panel (NET) kg(lb)
-
-
-
Layers limit (actually)
5 (6)
2 (3)
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
Max Working Pressure HP/LP Mpa (bar)
4.15/2.70 (41.5/27.0)
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range m (ft)
5 ~ 50m
(16.4 ~ 164.0)
-
Indoor unit & Outdoor unit height difference m (ft)
15m (OD located lower) / 30m (OD located higher)
(49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m
(0.538)
-
Pipe length for additional gas m (ft)
30m
(98.4)
-
*1 : In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 : If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230V shall
be used.
*3 : Network Impedance shall be applicable for EUROPE and CHINA models.
*4 : The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 : EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6 : SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season, Other fiche data
indicates in an attached sheet.
SM830274-02_欧州向けR410Aシングル_TD&SM.indb 2
19/09/26 17:01:42
1-1-5-3
1
1
Simultaneous (Triple) -Type
1-1. Unit Specifications
PE1
5. Ducted Type S-36PN1E5B×3 / U-100PE1E5A
INDOOR
MODEL
S-36PN1E5B×3
-
-
PANEL
MODEL
-
-
-
OUTDOOR
MODEL
-
U-100PE1E5A
-
Branch pipe
MODEL
-
Performance test condition
ISO13253 / EN14511 / EN14825 / EN12102
Power supply
Ø, Hz
1ø 50Hz
1ø 50Hz
V
220
230
240
220
230
240
Min
Max
C
O
O
L
I
N
G
Capacity
kW
10.0
10.0
10.0
-
-
-
3.3
12.5
BTU/h
34100
34100
34100
-
-
-
11300
42700
Current
A
0.42×3
0.43×3
0.44×3
11.3
10.9
10.5
-
-
Input power
W
90×3
95×3
100×3
2.400k
2.385k
2.370k
-
-
TOTAL W
-
2.670k
2.670k
2.670k
840
4.090k
Annual consumption
TOTAL kWh *
4
-
-
1335
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.75
3.75/A
3.75
3.93
3.06
Erp
*
6
Pdesign
kW
-
-
-
-
10.0
-
-
-
SEER
(W/W)
-
-
-
-
5.8
-
-
-
Annual consumption
kWh
-
-
-
-
600
-
-
-
Class
-
-
-
-
A+
-
-
-
Power factor
%
-
-
-
97
96
94
-
-
Noise indoor
dB-A (H/M/L)
35/33/30
-
-
-
Power Level dB
57/55/52
-
-
-
Noise outdoor
dB-A (H/L)
-
52/-
-
-
Power Level dB
-
69/-
-
-
H
E
A
T
I
N
G
Capacity
kW
11.2
11.2
11.2
-
-
-
4.1
14.0
BTU/h
38200
38200
38200
-
-
-
14000
47800
Current
A
0.42×3
0.43×3
0.44×3
12.5
12.3
11.8
-
-
Input power
W
90×3
95×3
100×3
2.680k
2.665k
2.650k
-
-
TOTAL W
-
2.950k
2.950k
2.950k
990
4.290k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.80
3.80/A
3.80
4.14
3.26
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
10.0
-
-
-
Tbivalent
°C
-
-
-
-
-10
-
-
-
SCOP
(W/W)
-
-
-
-
3.9
-
-
-
Annual consumption
kWh
-
-
-
-
3589
-
-
-
elbu(-10°C)
kW
-
-
-
-
0.00
-
-
-
Class
-
-
-
-
A
-
-
-
Power factor
%
-
-
-
97
95
94
-
-
Noise indoor
dB-A (H/M/L)
35/33/30
-
-
-
Power Level dB
57/55/52
-
-
-
Noise outdoor
dB-A (H/L)
-
52/-
-
-
Power Level dB
-
69/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
0.60×3/130×3 0.62×3/140×3 0.63×3/150×3 25.0/5.350k
25.0/5.550k
25.0/5.750k
-
Starting current(A)/Comp output(W)
-
-
-
12.5/3.0k
12.3/3.0k
11.8/3.0k
-
Network Impedance(ΩMAX.)
-
-
Fan motor output (Indoor/Outdoor) W
60×3
90×2
-
Moisture removal volume
L/h(Pt/h)
6.0
(2.0×3)
(12.6)
-
-
External static pressure
Pa
25 (MAX80)
-
-
Indoor
Air flow
Cooling
m³/min (ft³/min)
14.0×3/12.0×3/10.0×3 (494)×3/(424)×3/(353)×3
-
-
-
Heating
m³/min (ft³/min)
14.0×3/12.0×3/10.0×3 (494)×3/(424)×3/(353)×3
-
-
-
Outdoor
Air flow
Cooling
m³/min (ft³/min)
-
110.0
(3885)
-
-
Heating
m³/min (ft³/min)
-
95.0
(3355)
-
-
Refrigerant type / amount g(oz)
-
R410A
3.40k
(119.9)
-
Product dimension
Height mm(inch)
250 (9-27/32)
1416 (55-3/4)
-
Width
mm(inch)
780 [+100] (30-45/64 [+3-15/16])
940 (37-1/32)
-
Depth
mm(inch)
650 (25-19/32)
340 (13-13/32)
-
Product dimension (Panel) H×W×D mm, inch
-
-
-
Packing dimension
Height mm(inch)
338 (13-5/16)
1556
-
Width
mm(inch)
991 (39-1/64)
1055
-
Depth
mm(inch)
761 (29-61/64)
485
-
Weight
(NET)
kg(lb)
29 (64)
98 (216)
-
(GROSS) kg(lb)
34 (75)
108 (238)
-
Panel (NET) kg(lb)
-
-
-
Layers limit (actually)
5 (6)
1 (2)
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
Max Working Pressure HP/LP Mpa (bar)
4.15/2.70 (41.5/27.0)
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range m (ft)
5 ~ 75m
(16.4 ~ 246.1)
-
Indoor unit & Outdoor unit height difference m (ft)
15m (OD located lower) / 30m (OD located higher)
(49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m
(0.538)
-
Pipe length for additional gas m (ft)
30m
(98.4)
-
*1 : In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 : If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230V shall
be used.
*3 : Network Impedance shall be applicable for EUROPE and CHINA models.
*4 : The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 : EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6 : SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season, Other fiche data
indicates in an attached sheet.
SM830274-02_欧州向けR410Aシングル_TD&SM.indb 3
19/09/26 17:01:42
1-1-5-4
1
1
Simultaneous (Double-Twin) -Type
1-1. Unit Specifications
PE1
5. Ducted Type S-36PN1E5B×4 / U-125PE1E5A
INDOOR
MODEL
S-36PN1E5B×4
-
-
PANEL
MODEL
-
-
-
OUTDOOR
MODEL
-
U-125PE1E5A
-
Branch pipe
MODEL
-
Performance test condition
ISO13253 / EN14511 / EN14825 / EN12102
Power supply
Ø, Hz
1ø 50Hz
1ø 50Hz
V
220
230
240
220
230
240
Min
Max
C
O
O
L
I
N
G
Capacity
kW
12.5
12.5
12.5
-
-
-
3.3
14.0
BTU/h
42700
42700
42700
-
-
-
11300
47800
Current
A
0.42×4
0.43×4
0.44×4
16.8
16.3
15.7
-
-
Input power
W
90×4
95×4
100×4
3.530k
3.510k
3.490k
-
-
TOTAL W
-
3.890k
3.890k
3.890k
960
4.860k
Annual consumption
TOTAL kWh *
4
-
-
1945
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.21
3.21/A
3.21
3.44
2.88
Erp
*
6
Pdesign
kW
-
-
-
-
12.5
-
-
-
η
s,c
%
-
-
-
-
266.5
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
96
94
93
-
-
Noise indoor
dB-A (H/M/L)
35/33/30
-
-
-
Power Level dB
57/55/52
-
-
-
Noise outdoor
dB-A (H/L)
-
53/-
-
-
Power Level dB
-
70/-
-
-
H
E
A
T
I
N
G
Capacity
kW
14.0
14.0
14.0
-
-
-
4.1
16.0
BTU/h
47800
47800
47800
-
-
-
14000
54600
Current
A
0.42×4
0.43×4
0.44×4
16.6
16.1
15.6
-
-
Input power
W
90×4
95×4
100×4
3.520k
3.500k
3.480k
-
-
TOTAL W
-
3.880k
3.880k
3.880k
1.160k
5.360k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.61
3.61/A
3.61
3.53
2.99
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
12.5
-
-
-
Tbivalent
°C
-
-
-
-
-7
-
-
-
η
s,h
%
-
-
-
-
145.7
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
elbu(-10°C)
kW
-
-
-
-
2.38
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
96
95
93
-
-
Noise indoor
dB-A (H/M/L)
35/33/30
-
-
-
Power Level dB
57/55/52
-
-
-
Noise outdoor
dB-A (H/L)
-
53/-
-
-
Power Level dB
-
70/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
0.60×4/130×4 0.62×4/140×4 0.63×4/150×4 28.0/6.000k
28.0/6.200k
28.0/6.400k
-
Starting current(A)/Comp output(W)
-
-
-
16.8/3.0k
16.3/3.0k
15.7/3.0k
-
Network Impedance(ΩMAX.)
-
-
Fan motor output (Indoor/Outdoor) W
60×4
90×2
-
Moisture removal volume
L/h(Pt/h)
7.9
(1.9×4)
(16.6)
-
-
External static pressure
Pa
25 (MAX80)
-
-
Indoor
Air flow
Cooling
m³/min (ft³/min)
14.0×4/12.0×4/10.0×4 (494)×4/(424)×4/(353)×4
-
-
-
Heating
m³/min (ft³/min)
14.0×4/12.0×4/10.0×4 (494)×4/(424)×4/(353)×4
-
-
-
Outdoor
Air flow
Cooling
m³/min (ft³/min)
-
130.0
(4591)
-
-
Heating
m³/min (ft³/min)
-
110.0
(3885)
-
-
Refrigerant type / amount g(oz)
-
R410A
3.40k
(119.9)
-
Product dimension
Height mm(inch)
250 (9-27/32)
1416 (55-3/4)
-
Width
mm(inch)
780 [+100] (30-45/64 [+3-15/16])
940 (37-1/32)
-
Depth
mm(inch)
650 (25-19/32)
340 (13-13/32)
-
Product dimension (Panel) H×W×D mm, inch
-
-
-
Packing dimension
Height mm(inch)
338 (13-5/16)
1556
-
Width
mm(inch)
991 (39-1/64)
1055
-
Depth
mm(inch)
761 (29-61/64)
485
-
Weight
(NET)
kg(lb)
29 (64)
98 (216)
-
(GROSS) kg(lb)
34 (75)
108 (238)
-
Panel (NET) kg(lb)
-
-
-
Layers limit (actually)
5 (6)
1 (2)
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
Max Working Pressure HP/LP Mpa (bar)
4.15/2.70 (41.5/27.0)
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range m (ft)
5 ~ 75m
(16.4 ~ 246.1)
-
Indoor unit & Outdoor unit height difference m (ft)
15m (OD located lower) / 30m (OD located higher)
(49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m
(0.538)
-
Pipe length for additional gas m (ft)
30m
(98.4)
-
*1 : In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 : If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230V shall
be used.
*3 : Network Impedance shall be applicable for EUROPE and CHINA models.
*4 : The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 : EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6 :
η
s,c
and
η
s,h
classification is at 230V(400V) only in accordance with EN-14825. For heating,
η
s,h
indicates the value of only Average heating season.
SM830274-02_欧州向けR410Aシングル_TD&SM.indb 4
19/09/26 17:01:42
1-1-5-5
1
1
Simultaneous (Triple) -Type
1-1. Unit Specifications
PE1
5. Ducted Type S-45PN1E5B×3 / U-125PE1E5A
INDOOR
MODEL
S-45PN1E5B×3
-
-
PANEL
MODEL
-
-
-
OUTDOOR
MODEL
-
U-125PE1E5A
-
Branch pipe
MODEL
-
Performance test condition
ISO13253 / EN14511 / EN14825 / EN12102
Power supply
Ø, Hz
1ø 50Hz
1ø 50Hz
V
220
230
240
220
230
240
Min
Max
C
O
O
L
I
N
G
Capacity
kW
12.5
12.5
12.5
-
-
-
3.3
14.0
BTU/h
42700
42700
42700
-
-
-
11300
47800
Current
A
0.54×3
0.55×3
0.56×3
16.8
16.3
15.8
-
-
Input power
W
115×3
120×3
125×3
3.545k
3.530k
3.515k
-
-
TOTAL W
-
3.890k
3.890k
3.890k
940
4.840k
Annual consumption
TOTAL kWh *
4
-
-
1945
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.21
3.21/A
3.21
3.51
2.89
Erp
*
6
Pdesign
kW
-
-
-
-
12.5
-
-
-
η
s,c
%
-
-
-
-
263.9
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
96
94
93
-
-
Noise indoor
dB-A (H/M/L)
36/34/30
-
-
-
Power Level dB
58/56/52
-
-
-
Noise outdoor
dB-A (H/L)
-
53/-
-
-
Power Level dB
-
70/-
-
-
H
E
A
T
I
N
G
Capacity
kW
14.0
14.0
14.0
-
-
-
4.1
16.0
BTU/h
47800
47800
47800
-
-
-
14000
54600
Current
A
0.54×3
0.55×3
0.56×3
16.7
16.1
15.8
-
-
Input power
W
115×3
120×3
125×3
3.535k
3.520k
3.505k
-
-
TOTAL W
-
3.880k
3.880k
3.880k
1.140k
5.340k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.61
3.61/A
3.61
3.60
3.00
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
12.5
-
-
-
Tbivalent
°C
-
-
-
-
-7
-
-
-
η
s,h
%
-
-
-
-
145.5
-
-
-
Annual consumption
kWh
-
-
-
-
-
-
-
-
elbu(-10°C)
kW
-
-
-
-
2.38
-
-
-
Class
-
-
-
-
-
-
-
-
Power factor
%
-
-
-
96
95
93
-
-
Noise indoor
dB-A (H/M/L)
36/34/30
-
-
-
Power Level dB
58/56/52
-
-
-
Noise outdoor
dB-A (H/L)
-
53/-
-
-
Power Level dB
-
70/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
0.76×3/165×3 0.79×3/180×3 0.80×3/190×3 28.0/6.000k
28.0/6.200k
28.0/6.400k
-
Starting current(A)/Comp output(W)
-
-
-
16.8/3.0k
16.3/3.0k
15.8/3.0k
-
Network Impedance(ΩMAX.)
-
-
Fan motor output (Indoor/Outdoor) W
85×3
90×2
-
Moisture removal volume
L/h(Pt/h)
7.9
(2.6×3)
(16.6)
-
-
External static pressure
Pa
25 (MAX80)
-
-
Indoor
Air flow
Cooling
m³/min (ft³/min)
16.0×3/13.0×3/11.0×3 (565)×3/(459)×3/(388)×3
-
-
-
Heating
m³/min (ft³/min)
16.0×3/13.0×3/11.0×3 (565)×3/(459)×3/(388)×3
-
-
-
Outdoor
Air flow
Cooling
m³/min (ft³/min)
-
130.0
(4591)
-
-
Heating
m³/min (ft³/min)
-
110.0
(3885)
-
-
Refrigerant type / amount g(oz)
-
R410A
3.40k
(119.9)
-
Product dimension
Height mm(inch)
250 (9-27/32)
1416 (55-3/4)
-
Width
mm(inch)
780 [+100] (30-45/64 [+3-15/16])
940 (37-1/32)
-
Depth
mm(inch)
650 (25-19/32)
340 (13-13/32)
-
Product dimension (Panel) H×W×D mm, inch
-
-
-
Packing dimension
Height mm(inch)
338 (13-5/16)
1556
-
Width
mm(inch)
991 (39-1/64)
1055
-
Depth
mm(inch)
761 (29-61/64)
485
-
Weight
(NET)
kg(lb)
29 (64)
98 (216)
-
(GROSS) kg(lb)
34 (75)
108 (238)
-
Panel (NET) kg(lb)
-
-
-
Layers limit (actually)
5 (6)
1 (2)
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
Max Working Pressure HP/LP Mpa (bar)
4.15/2.70 (41.5/27.0)
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range m (ft)
5 ~ 75m
(16.4 ~ 246.1)
-
Indoor unit & Outdoor unit height difference m (ft)
15m (OD located lower) / 30m (OD located higher)
(49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m
(0.538)
-
Pipe length for additional gas m (ft)
30m
(98.4)
-
*1 : In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 : If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230V shall
be used.
*3 : Network Impedance shall be applicable for EUROPE and CHINA models.
*4 : The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 : EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6 :
η
s,c
and
η
s,h
classification is at 230V(400V) only in accordance with EN-14825. For heating,
η
s,h
indicates the value of only Average heating season.