Opening the Intake Grille
Opening the Screw Caps
• Remove the control box cover and insert the cable into the main unit 
through the cable holder located on the side.
• Check the colors of the wires on the terminal board, and secure 
them with screws.
• Secure the outer sheath of the connecting cable with the cord clamp. 
• Reattach the control box cover in its original position.
• Connect the indoor/outdoor connecting cable using the 
prescribed cable, and secure it firmly so that external force from 
the cable is not transmitted to the terminal connectors.
• Lift up the decorative grille from directly below to match it with the main 
unit, and tentatively secure it in place.
• Open the intake grille and the screw caps, and secure the decorative 
grille using the lock screws (4).
• When finishing the ceiling after the air conditioner has been installed, use the pattern       
    8  to indicate the ceiling opening dimensions as shown below. (The protection sheet 
of the pattern is used to prevent the air conditioner discharge vent from becoming 
dirty, so wrap it around the discharge vent as shown in the illustration.)
Connecting the Indoor/Outdoor Connecting Cable
8
Attaching the Decorative grille
9
Using the Pattern   8 
• Connecting cable between indoor unit and outdoor unit shall be 
approved polychloroprene sheathed 4 
× 1.5 mm
2
 flexible cord, type 
designation 245 IEC 57(H05RN-F) or heavier cord. 
   • Ensure the color of wires of outdoor unit and the terminal Nos. 
are the same to the indoor’s  respectively.
   • Earth lead wire shall be longer than the other lead wires as 
shown in the figure for the electrical safety in case of the slipping 
out of the cord from the anchorage. 
Terminals on the indoor unit
1          2         3
Color of wires
Terminals on the outdoor unit
1          2         3
 • Secure the cable onto the control board with the holder (clamper).
Press the three locations shown 
below and open the grille.
Press the edge (outside) of the 
screw cap to open it.
Indoor/outdoor 
connection terminals
Earth wire
Cord clamp
Indoor/outdoor 
connecting cable
Control box cover 
lock screw
Control box cover
Insert
Cable holder
Indoor/outdoor
connecting cable
Fold back the protection sheet
and affix using double-sided 
adhesive tape
Air conditioning unit
Pattern attachment 
hole (small hole)
Pattern fixing screw
 9  (4)
Discharge vent
Pattern  8
Decorative 
grille 
temporary 
hooks
Decorative 
grille 
temporary 
hooks
Air conditioning 
unit
Air conditioning 
unit
Screw cap
Screw cap
Lock screw (4)
(supplied with the decorative grille)
Decorative 
grille
Screw cap
Press Decorative grille
Intake grille
CS
-M
E
7C
B
1P
/
C
S
-M
E
10CB1
P
/
CS
-M
E
12CB1
P
/
CS
-M
E
14CB1
P
/
CS
-M
E
10CD3
P
/
CS
-M
E
14
CD3P
33
OPEN
Is there any gas leakage at  
flare nut connections?
Is the power supply voltage 
complied with rated value?
Is there any abnormal sound?
Is the cooling / heating operation 
normal?
Is the thermostat operation 
normal?
Is the remote control’s LCD 
operation normal?
Has the heat insulation been carried  
out at flare nut connection?
Is the connecting cable being fixed 
to terminal board firmly?
Is the connecting cable being  
clamped firmly?
Is the drainage ok?
(Refer to “Check the drainage” 
 section)
Is the earth wire connection 
properly done? 
ENGLISH
MATSUSHITA ELECTRIC INDUSTRIAL CO., LTD.
Web Site : http://www.panasonic.co.jp/global/
F612424  
PRINTED IN JAPAN
CHECK ITEMS
The below operations will be performed by pressing the “AUTO” switch.
1. AUTO OPERATION MODE
1.
The Auto operation will be activated 
immediately once the “AUTO” switch is pressed.
2. TEST RUN OPERATION (FOR PUMP 
DOWN/SERVICING PURPOSE)
     The Test Run operation will be activated if 
the “AUTO” switch is pressed continuously for 
more than 5 sec. to below 8 sec..
1.
A short beep sound will occur at the fifth sec., 
in order to identify the starting of Test Run 
operation.
• When installing two air conditioners in one room, each air conditioner can be 
synchronized to the remote control.
In order to operate separately, open the rear cover of one of the remote control and set 
to “B”.
Setting the air conditioner unit to “B”
1. Press the “AUTO” switch for about 11 to 15 seconds.  When you hear three short beeps,  
release the switch.
1. 
Note: you will hear one short beep in about 5 seconds, and then two short beeps in about 
8 seconds.
2. Press again the  “AUTO”  switch within 60 seconds.  Every press the “AUTO” switch, you 
will hear a short beep.  When you hear eventually a long beep, stop pressing the
 “AUTO” switch , which achieves “B” setting.
1. 
If you stop pressing the “AUTO” switch midway at the short beep, this will achieve 
“A” setting.
3. After 60 seconds or longer of the above setting, use the “B” set remote control to confirm 
successful operation.
Set “B” on the remote control.
This can be achieved by cutting 
the jumper wire of the remote 
control with a cutter.
Changing the remote control transmission code
AUTO SWITCH OPERATION
Remote control
Give two cuts.
Side view of jumper
The disconnected jumper 
wire is “B” setting.
Jumper wire
“DRAIN TEST” 
 switch
“AUTO” switch
CS
-M
E
7C
B
1P
/
C
S
-M
E
10CB1
P
/
CS
-M
E
12CB1
P
/
CS
-M
E
14CB1
P
/
CS
-M
E
10CD3
P
/
CS
-M
E
14
CD3P
34
10.2. Duct Type
1. Philips screw driver
2. Level gauge
3. Electric drill, hole core drill 
 
(ø70 mm)
4. Hexagonal wrench (4 mm)
5. Spanner
6. Pipe cutter
7. Reamer
8. Knife
9. Gas leak detector
10. Measuring tape
11. Thermometer
12. Megameter
13. Multimeter
14. Torque wrench
      18 N•m (1.8 kgf.m)
      42 N•m (4.2 kgf.m)
15. Vacuum pump
16. Gauge manifold
Required tools for Installation Works
SAFETY PRECAUTIONS
•   Read the following “SAFETY PRECAUTIONS” carefully before installation.
•   Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main 
circuit for the model to be installed.
•   The caution items stated here must be followed because these important contents are related to safety. The meaning of 
each indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the 
seriousness is classified by the following indications.
•   Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, 
care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future 
reference.
WARNING
This indication shows the possibility of causing death or serious injury.
CAUTION
This indication shows the possibility of causing injury or damage to properties only.
Symbol with background white denotes item that is PROHIBITED from doing.
WARNING
1)
Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, 
electrical shock or fire.
2)
Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical 
shock or fire.
3)
Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, 
fire or electrical shock.
4)
Install at a strong and firm location which is able to withstand the set's weight. If the strength is not enough or 
installation is not properly done, the set will drop and cause injury.
1)
This equipment must be earthed. It may cause electrical shock if grounding is not perfect.
5)
For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent 
circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will
cause electrical shock or fire.
3)
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and 
damage the furniture.
7)
Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed 
perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock.
6)
Use the specified cable (1.5 mm
2
) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable 
so that no
 externa
l force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the 
connection.
8)
When carrying out piping connection, take care not to let air substances other than the specified 
refrigerant go into refrigeration cycle.
8)
Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and 
injury.
9)
When connecting the piping, do not allow air or any substances other than the specified refrigerant 
(R410A) to enter the refrigeration cycle. Otherwise, this may lower the capacity, cause abnormally high 
pressure in the refrigeration cycle, and possibly result in explosion and injury.
10) Do not modify the length of the power supply cord or use of the extension cord, and do not share the 
single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.
2)
Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and 
accumulates at surrounding of the unit, it may cause fire.  
2)
Do not release refrigerant.
3)
Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take 
care of the liquid refrigerant, it  may cause frostbite.
3)
Installation work.
4)
It may need two people to carry out the installation work.
4)
Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
1)
Selection of the installation location.
1)
Select a installation location which is rigid and strong enough to support or hold the unit, and select a location for easy 
maintenance.
The items to be followed are classified by the symbols:
CAUTION
ATTENTION
Installation Instructions
CS
-M
E
7C
B
1P
/
C
S
-M
E
10CB1
P
/
CS
-M
E
12CB1
P
/
CS
-M
E
14CB1
P
/
CS
-M
E
10CD3
P
/
CS
-M
E
14
CD3P
35
Liquid side
Gas side
ø 6.35 (1/4") t 0.8
ø 9.52 (3/8") t 0.8
CAUTION
When the wall is hollow, 
please be sure to use the 
sleeve for tube ass'y to 
prevent dangers caused by 
mice biting the connecting 
cable. 
Attaching the remote control holder to the wall
1
2
6
3
4
5
7
8
10
9
11
12
Indoor Unit Accessory Parts
1
2
1
2
1
1
2
1
1
1
2
2
Required Materials
• Read the catalog and other technical materials and prepare the required materials.
Product name                                                    Remarks
VP20 (outer diameter ø26); also sockets, 
elbows and other parts as necessary
PVC adhesive
For refrigerant piping insulation (foamed 
polyethylene with a thickness of 8 mm or more)
For drain piping insulation (foamed polyethylene 
with a thickness of 10 mm or more)
× 1.5 mm
2
 flexible cord, type designation 
245 IEC 57 (H05RN-F)
Hanging bolts (M10) (4) and nuts (12), Flat 
washers (8) (when hanging the indoor unit)  
Rigid PVC pipe
Adhesive
Insulation
  
Indoor/outdoor connecting cable
Hanging bolt related parts
Other Items to be Prepared (Locally Purchased)
Take into consideration the following contents when creating the blueprint.
Indoor unit installation location
Remote control mounting location
The location should be strong enough to support the main unit 
without vibration.
There should not be any heat or steam sources nearby.
Drainage should be easy. Avoid locating the drain port close to 
ditches (domestic wastewater).
Avoid locations above entrances and exits.
Do not block the intake and discharge.
Select the location so that the cool and warm air spreads 
throughout the entire room.
Locate the indoor unit at least 1 m or more away from a TV, radio, 
wireless equipment, antenna cables and fluorescent lights, and 2 
m or more away from a telephone.
Note that if the air conditioning unit is installed near an 
electronically lit fluorescent light (inverter, rapid start type, etc.), 
it may not receive the remote control signals.
Signals may not be transmitted and received correctly when 
the remote control is operated while in the holder. Take the 
remote control in your hand to operate the unit.
Mount the holder in a location that is not subject to the 
effects of heat (direct sunlight and stoves, etc.).
Selecting the Installation Location
1
Selecting the Piping
2
To Drill a Hole in the Wall and 
Install a Sleeve of Piping
3
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes 
about 15 mm from the wall.
4. Finish by sealing the sleeve with 
putty or caulking compound at the 
final stage. 
• Prepare the piping set shown in the table 
below or equivalent products for the 
refrigerant piping.
* See the Outdoor Unit Installation 
  Instructions.
Remote control holder
fixing screws 
Remote control 
holder
Remote
control  3
5
6
Bushing for 
tube ass'y 
15 mm
Outdoor
Indoor
Wall
Sleeve for 
tube ass'y
ø70 through 
hole
Putty or caulking 
compound
Approx. 
5 - 7 mm
Piping 
insulation
Band
Remote control
Battery
Remote control holder
Drain hose insulation   
Receiver
Remote control holder  
fixing screw
Receiver cover
Clamp 
Clamp mounting screw
Receiver mount
No.
No.
Accessory part
Accessory part
Qty.
Qty.
CS
-M
E
7C
B
1P
/
C
S
-M
E
10CB1
P
/
CS
-M
E
12CB1
P
/
CS
-M
E
14CB1
P
/
CS
-M
E
10CD3
P
/
CS
-M
E
14
CD3P
36
Page of 69
Display

Click on the first or last page to see other CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P service manuals if exist.