Panasonic CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Simplified Service Manual ▷ View online
1 Features
3
2 About Lead Free Solder (PbF)
3
2.1.
DISTINCTION OF PbF P.C. BOARD
3
2.2.
CAUTION
3
3 Functions
4
3.1.
REMOTE CONTROL
4
3.2.
INDOOR UNIT
5
4 Product Specifications
7
5 Dimensions
8
© 2003 Matsushita Electric Industrial Co., Ltd. All
rights
rights
CS-ME7CB1P
CS-ME10CB1P
CS-ME12CB1P
CS-ME14CB1P
CS-ME10CD3P
CS-ME14CD3P
CS-ME10CB1P
CS-ME12CB1P
CS-ME14CB1P
CS-ME10CD3P
CS-ME14CD3P
5.1.
Cassette Type
8
5.2.
Grille
10
5.3.
Duct Type
11
6 Refrigeration Cycle Diagram
12
7 Block Diagram
13
8 Wiring Diagram
14
8.1.
Cassette Type (CS-
ME7CB1P/ME10CB1P/ME12CB1P/ME14CB1P)
14
8.2.
Duct Type (CS-ME10CD3P/ME14CD3P)
15
Multi Air Conditioner
Please file and use this manual together with the service manual for Model No. CS-ME7CKPG, CS-
ME10CKPG, CS-ME12CKPG, CS-ME14CKPG, CS-ME18CKPG, CU-2E15CBPG, CU-2E18CBPG, CU-
3E23CBPG, CU-4E27CBPG, Order No. RAC0209005C2.
ME10CKPG, CS-ME12CKPG, CS-ME14CKPG, CS-ME18CKPG, CU-2E15CBPG, CU-2E18CBPG, CU-
3E23CBPG, CU-4E27CBPG, Order No. RAC0209005C2.
CONTENTS
Page
Page
ORDER NO. RAC0312001A8
9 Operation Details (Functions & Protection)
16
9.1.
Simultaneous Operation Control
16
9.2.
Airflow Direction Control (Cassette Type only)
17
9.3.
Indoor Fan Control
18
9.4.
Drain Pump Control
20
9.5.
Auto Restart Control
21
9.6.
Other Indoor Unit Operation Functions
22
10 Installation Instructions
30
10.1. Cassette Type
30
10.2. Duct Type
35
11 Operating Instructions
41
12 Disassembly of Parts
53
12.1. Cassette Type (Indoor Unit: CS-
ME7CB1P/ME10CB1P/ME12CB1P/ME14CB1P)
53
12.2. Duct Type (Indoor Unit: CS-ME10CD3P/ME14CD3P) 57
13 Technical Data
59
13.1. OPERATION CHARACTERISTICS
59
14 Electronic Circuit Diagram
63
14.1. REMOTE CONTROL
63
14.2. Cassette Type
64
14.3. Duct Type
65
15 Exploded View & Replacement Parts List
66
15.1. CS-ME7CB1P/ME10CB1P/ME12CB1P/ME14CB1P
66
15.2. CS-ME10CD3P/ME14CD3P
68
2
CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P
·
Serviceability
−
−
−
−
Self diagnosis
−
−
−
−
Test Run at both Cooling and Heating rated frequency
·
Built-in drain pump (Cassette and Duct type)
−
−
−
−
A drain pump is built in.
The pipe can rise to 200 mm above the drain outlet.
1 Features
·
Product
−
−
−
−
A single OUTDOOR unit enables air conditioning of up to four separate rooms
Remarks:
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
capacity range of outdoor unit. (Shown in the above table)
Example: The below indoor units combination is not possible to connect CU-3E23CBPG. (Total nominal capacity
of indoor unit is between 5.0kW and 10.0kW)
1) Two CS-ME7CB1P only. (Total nominal cooling capacity is 4.4kW)
2) Three CS-ME14CB1P only. (Total nominal cooling capacity is 12.0kW)
of indoor unit is between 5.0kW and 10.0kW)
1) Two CS-ME7CB1P only. (Total nominal cooling capacity is 4.4kW)
2) Three CS-ME14CB1P only. (Total nominal cooling capacity is 12.0kW)
−
−
−
−
Inverter controlled for High energy efficiency and optimal comfort
−
−
−
−
New refrigerant R410A is used for protecting ozone layer
−
−
−
−
Lead - free P.C. Board
2 About Lead Free Solder (PbF)
2.1. DISTINCTION OF PbF P.C. BOARD
P.C. Boards (manufactured) using lead free solder will have a PbF stamp on the P.C. Board.
2.2. CAUTION
·
Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70 °F (30 - 40 °C) higher.
Please use a high temperature solder iron and set it to 700 ± 20 °F (370 ± 10 °C).
Please use a high temperature solder iron and set it to 700 ± 20 °F (370 ± 10 °C).
·
Pb free solder will tend to splash when heated too high (about 1100 °F/ 600 °C).
If you must use Pb solder, please completely remove all of the Pb free solder on the pins or solder area before applying Pb
solder. If this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
solder. If this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
3
CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P
3 Functions
3.1. REMOTE CONTROL
4
CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P