Panasonic CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Simplified Service Manual ▷ View online
1
2
3
Push
Push
Push
Care and maintenance
Cleaning the intake grille
(Must be removed from unit before washing)
1
Raise the intake grille (Keep hold of the intake grille when detaching it.)
Press in the 3 places shown to open
the intake grille.
the intake grille.
Hold onto the intake grille and slide the
release lever to release the hinge.
release lever to release the hinge.
2
Wash and dry the intake grille
Cleanse with a soft cloth and sponge.
Then, wipe dry the excess moisture and leave the panel to dry in the shade.
Then, wipe dry the excess moisture and leave the panel to dry in the shade.
●
Avoid pressing hard on the surface and avoid the use of a hard brush. (To prevent injuries)
●
Apply some mild kitchen detergent (neutral type) to wash off stubborn dirt and grime.
●
Avoid drying the panel in direct sunlight or over a stove.
(May cause color fading and structural distortions)
(May cause color fading and structural distortions)
3
To fix the intake grille
Cassette Type
Release the string from the intake grille.
Release lever
Fit the grille to the hinge on the right of
the main unit.
the main unit.
Slide and hold the release lever in
place, then fit the grille into place and
release the lever.
place, then fit the grille into place and
release the lever.
Right hinge
Release lever
Left hinge
Release lever
Center hinge
Right hinge
Intake grille
String
(stops the grille from falling)
Attach the string to the grille, then press
in the 3 places (shown in the first
illustration in step
in the 3 places (shown in the first
illustration in step
1
) to close the intake
grille.
49
CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P
Troubleshooting
The following symptoms are not faults. Please continue to use it without fear.
Is it faulty?
No, it is okay
There is noise.
●
Sound of flowing water:
• Caused by the flow of refrigerant gas through the air conditioner system.
• Caused by the flow of condensated water by drain pump.
• Caused by the flow of refrigerant gas through the air conditioner system.
• Caused by the flow of condensated water by drain pump.
For details about items not covered here, read the operating instructions attached at the outdoor uint for model
CS-ME7CKPG.
CS-ME7CKPG.
Self diagnosis
Is it okay?
Consult your dealer
■
The TIMER lamp blinks
Notify them of all abnormalities.
You can self diagnose using the remote
control. Follow the instructions below. After
confirmation, stop all operations and switch
off the power supply.
control. Follow the instructions below. After
confirmation, stop all operations and switch
off the power supply.
■
How to self diagnosis
1
Press
for 5 seconds
●
3 alphanumeric digits will appear on the remote control display.
2
When the indoor unit gives off a continuous
“Beep, Beep, Beep, Beep” sound, slowly and
repeatedly press
“Beep, Beep, Beep, Beep” sound, slowly and
repeatedly press
●
Inform your dealer on the displayed 3 alphanumeric digits.
DISPLAYED ALPHANUMERIC DIGITS
H
F
The H and F (followed by 2 numerals)
represent different sets of abnormalities.
represent different sets of abnormalities.
When H33, H36 and H37 are displayed, you must not
operate until repairs have been done.
operate until repairs have been done.
H36 : Heating • Air circulation
H37 : Cooling • Dry • Air circulation
H37 : Cooling • Dry • Air circulation
Cassette Type
Duct Type
POWER
TIMER
ODOUR WASH
POWER
TIMER
ODOUR
WASH
AUTO
OFF/ON
Receiver unit
POWER
TIMER
ODOUR WASH
“Beep, Beep,
Beep, Beep”
Press
for 5 seconds, using the remote control select and
operate the Heating • Cooling • Dry • Air circulation modes. (There will
be “Beep, Beep, Beep, Beep” sound to confirm the command is
received).
be “Beep, Beep, Beep, Beep” sound to confirm the command is
received).
50
CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P
Helpful Information
■
When the remote control is not available and the batteries are out.
It is still possible for emergency operations. In this case, the unit will operate on the default temperature of 25°C.
Adjustment to the default temperature is not allowed.
Adjustment to the default temperature is not allowed.
Auto operation
button
button
1
Switch on the power supply
2
Press the auto operation button.
■
To stop operation, press the button once more.
Helpful Information
Cassette Type
Duct Type
AUTO
OFF/ON
POWER
TIMER
ODOUR
WASH
AUTO
OFF/ON
Auto operation button
■
Placing things around the indoor unit:
Allow a lot of spacing if you wish to place things around the indoor unit.
If tall furniture are placed near the unit, it may hinder the air flow which will reduce the efficiency of the unit.
If tall furniture are placed near the unit, it may hinder the air flow which will reduce the efficiency of the unit.
■
When the unit is not operated for an extended period of time:
■
When there is a power failure
●
During operation:
All operations stopped. When power supply is restored, run operations all over again.
All operations stopped. When power supply is restored, run operations all over again.
●
During preset timer mode:
The timer mode is cancelled. (The indoor unit TIMER lamp will be off) When power supply is restored, reset TIMER
once again.
The timer mode is cancelled. (The indoor unit TIMER lamp will be off) When power supply is restored, reset TIMER
once again.
■
When there is thunder in the vicinity:
To avoid lightning strikes, stop all operations and switch off the power supply. (To protect the air conditioner)
■
After you have used wax:
Be sure the furniture wax is fully dried before starting the air conditioner.
Operate the AIR CIRCULATION
mode for 2 to 3 hours
mode for 2 to 3 hours
(To dry the interior sections of the
indoor unit)
indoor unit)
Stop the operations
and switch off the
power supply.
and switch off the
power supply.
Remove all batteries from the
remote control.
remote control.
(To prevent electrolyte leakage)
51
CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P
1) This appliance must be earthed.
2) If the supply cord is damaged or needed to be replaced, it must be replaced by authorized
service agent or a similarly qualified person in order to avoid a hazard.
3) Remove power plug or disconnect from the main power supply before servicing this
appliance.
4) Do not repair by yourself.
In case of malfunction of this appliance, do not repair by yourself.
Contact to the sales dealer or service dealer for a repair.
Contact to the sales dealer or service dealer for a repair.
5) Do not use in an explosive atmosphere.
Do not use this appliance in a potentially explosive atmosphere.
6) Turn off the power (Isolation from main power supply).
Pull off the power plug from the receptacle, or switch off the breaker, or switch off power
disconnecting mean to isolate the equipment from the main power supply in case of an
emergency.
disconnecting mean to isolate the equipment from the main power supply in case of an
emergency.
■
Notes
• If the unit is not going to be used for an extended period of time, turn off the main Power
supply. If it is left at the ON position, approximately 14 W of electricity will be used even if
the indoor unit has been turned off with the remote control.
the indoor unit has been turned off with the remote control.
• If operation is stopped, then restart immediately, the unit will resume operation only after 3
minutes.
Use under the following conditions
DBT:Dry Bulb Temp
WBT:Wet Bulb Temp
Maximum Temperature
Minimum Temperature
Cooling
Indoor
DBT
WBT
32
23
16
11
DBT
WBT
43
26
16
11
Outdoor
Indoor
DBT
WBT
WBT
30
–
2
–
DBT
24
18
-5
-6
Outdoor
Heating
(Unit in
°
C)
* Airborne noise.
A-weighted sound pressure level of this appliance is less than 70dB (A) under the JIS
C 9612 test conditions.
C 9612 test conditions.
Maximum cooling operation 1 m from the unit
Safety Precaution
WARNING
52
CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P
Click on the first or last page to see other CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P service manuals if exist.