CONNECTING THE WIRES TO THE CONTROL BOX
 • Remove a two mounting screw, remove the control box
cover, and then connect the wires by following the
procedure given in the illustration.
Caution Make sure that screws of the terminal are securely
tightened.
10.4.7. Electrical wiring
As to the main power source and cable size of outdoor unit, read the installation manual attached to the outdoor unit.
Warning
The units must be connected to the supply cables for fixed wiring by qualified technician.
Feed the power source to the unit via a diatribution switch board designed for this purpose, the switch should disconnected all
poles with a contact separation of at least 3mm.
When the supply cable is damaged, it must be replaced by qualified technician.
Caution
Be sure to install a current leakage breaker, main switch and fuse to the main power supply, otherwise electric shocks may
result.
Caution
Be sure to connect the unit to secure earth connection.
If the earthing work is not carried out properly, electric shock may result.
Warning
Wiring shall be connected securely using specified cables and fix them securely so that external force of the cables may not
transfer to the terminal connection section. Imperfect connection and fixing leads to fire, etc.
 1. Select a power source that is capable of supplying the current required by the air conditioner.
 2. Be sure to connect the wires correctly to terminal board with connecting the crimp tyre ring terminal to the wires.
 3. Be sure to turn off the main power before installing and connecting the remote controller.
Note
If momentarily turning on the power supply for both the indoor and outdoor units, do not turn the power off after again until at
least 1 minute has passed. (for the system’s automatic setting.)
Turning off the power supply on the way may cause an abnormal operation.
 • Use the standard power cord for Europe (such as HO5RN-F or HO7RN-F which conforms to CENELEC (HAR) rating
specifications) or use the cable based on IEC standard. (245IEC57, 245IEC66)
37
CS-F18DTE5 CU-L34DBE5 /
10.4.8. Settings
Do not operate the remote controller within 1 minute after turning on the power of the indoor unit.
When using group control with the standard type, at least 1 unit must be set at No.1 at the indoor unit.
Check the settings of the indoor unit in a case where there are no display at remote controller. If there is no problem to the settings,
either group control or standard type should be set at No.16 at the indoor unit before turning the power on again.
 • All sets in the group which uses the same remote controller thermistor settings can be controlled by the same remote controller
thermistor.
 • Up to a maximum of 16 indoor units can be connected at the time of group control. (Do not connect heat pump unit with cooling
only unit.)
 • Indoor unit No. will be set automatically at the time of group control. However, which indoor unit uses which number is unknown.
Indoor unit No. is also possible to be set manually with DIP switches. Since manual address setting has priority to automatic
address setting. To perform automatic address settings after doing manual setting, turn off all DIP switches from No.1 to No.4,
and then stop the operation. Then press three switches such as [AIR SWING AUTO] . [MODE]. [A/C No.] at the same time. (Do
not use manual address setting and automatic address setting together.)
 • Centralized control is possible for master unit and slave unit at the time of group control.
(Remote Control Address Setting)
(Refer to the Operation Manual which is provided with the remote controller for details.)
 • Two remote controllers (including the wireless remote controller) can be connected. However, remote control thermistor
setting is not possible.
 • As for [master/slave] setting of remote controller, the automatic setting and manual setting are possible. Since manual
setting is priority.
 • Two remote controllers, which both are wireless, cannot be connected.
10.4.9. As for timer output
 • Connect the timer cord to connector (CN-TIMER) on print circuit board.
10.4.10. Precautions in test run
 • The initial power supply must provide at least 90% of the rated voltage. Otherwise, the air conditioner may not operate.
 • Test operation can be carried out using the remote control unit or at the outdoor unit. (If carrying out test operation at the
outdoor unit, refer to “TEST OPERATION” in the outdoor unit installation manual.)
 • If using the remote control unit to carry out test operation, follow the procedure given below.
38
CS-F18DTE5 CU-L34DBE5 /
Is circulation of air adequate?
Is draining smooth?
Is heat insulation complete (refrigerant and drain piping)?
Is there any leakage of refrigerant?
Is remote controller switch operated?
Is there any faulty wiring?
Are the terminal screws loosened?
M3...69-98 N.cm {7-10 kgf.cm}
M4...157-196 N.cm {16-20 kgf.cm}
M5...196-245 N.cm {20-25 kgf.cm}
 • First, press the OFF/ON ( ) button.
 • Then press the TEST RUN button within 1 minute of pressing the OFF/ON ( )
button.
 • Next, select the operation modes.
 • The temperature of the indoor unit pipes will be shown on the temperature setting
display. (At the start of the test operation, it may take up to 1 minute for air
conditioner number, switching time and other displays to appear.)
 • After operation modes have been selected, stop the compressor for a moment.
 • Press the OFF/ON ( ) button of the TEST RUN button once more to cancel test
operation mode.
NOTE 1
These units are equipped with connection error prevention circuits. If the units do not operate, it is possible that the
connection error prevention circuits have operated. In such cases, check that the power wires (connected to terminals
and
) and the control wires
) are connected correctly. If they are connected incorrectly, connect them correctly.
Normal operation should then commence.
NOTE 2
Do not short the remote control unit wires to each other. (The protection circuit will be activated and the units will not operate.)
Once the cause of the short is eliminated, normal operation will then be possible.
NOTE 3
When running the units in heating mode during test operation, be sure to run the units in cooling mode first before selecting
this mode. If heating mode is selected first, it may cause problems with operation of the compressor. (Heat pump model only.)
NOTE 4
Test operation should be carried out for a minimum of 5 minutes. (Test operation will be cancelled automatically after 30
minutes.)
NOTE 5
Test operation mode should always be cancelled once test operation itself has been completed.
10.4.11. Check the following items when installation is complete
 • After completing work, be sure to measure and record trial run properties, and store measuring data, etc.
 • Measuring items are room temperature, outside temperature, suction temperature, blow out temperature, wind velocity, wind
volume, voltage, current, presence of abnormal vibration and noise, operating pressure, piping temperature, compressive
pressure, airtight pressure.
 • As to the structure and appearance, check the following items .
10.4.12. Hand over
 • Teach the customer the operation and maintenance procedures, using the operation manual (air filter cleaning, temperature
control, etc.)
As to parts to be sold separately
 • With regards to installation of the parts sold separately, follow the installation manual which is provided with the parts sold
separately
As for work specifications of the outdoor unit, read the OUTDOOR UNIT INSTALLATION MANUAL attached to the outdoor
unit.
39
CS-F18DTE5 CU-L34DBE5 /
This mark means “Caution” or “Warning”.
This mark means “Earth”.
10.5. Outdoor unit installation
AIR CONDITIONERS OUTDOOR UNIT INSTALLATION INSTRUCTIONS
Precautions in terms of safety
Carry out installation work with reliability after thorough reading of this “Precautions in terms of safety”.
 • Precautions shown here are differentiated between
Warnings
and
Cautions . Those that have much chances for
leading to significant result such as fatality or serious injury if wrong installation would have been carried out are listed compiling
them especially into the column of
Warnings .
However, even in the case of items which are listed in the column of
Cautions , such items also have a chance for leading
to significant result depending on the situations.
In either case, important descriptions regarding the safety are listed, then observe them without fail.
 • As to indications with illustration
 • After installation work has been completed, do not only make sure that the unit is free from any abnormal condition through the
execution of try run but also explain how to use and how to perform maintenance of this unit to the customer according to the
instruction manual.
In addition, request the customer to keep this manual for installation work together with instruction manual.
Warnings
The appliance must be installed by technician, who takes into
account the requirements given by ISO5149 or eventual
equivalent requirements.
If installing inside a small room, measures should be taken to
prevent refrigerant levels from building up to critical
concentrations in the event of a refrigerant leak occurring.
Please discuss with the place of purchase for advice on what
measures may be necessary to prevent critical concentrations
being exceeded. If the refrigerant leaks and reaches critical
concentration levels, there is the danger that death from
suffocation may result.
As to installation, request the distributor or vendor to perform it.
Imperfection in installation caused by that having been carried
out by the customer himself may lead to water leakage, electric
shock, fire, etc.
Securely attach the protective covers for the outdoor unit
connection cables and power cord so that they do not lift up
after installation. If the covers are not properly attached and
installed, the terminal connections may overheat, and fire or
electric shock may result.
Carry out the installation work with reliability according to this
manual for installation work.
Imperfection in installation leads to water leakage, electric
shock, fire, etc.
Switch off all supplies before accessing any electrical part.
Carry out the installation work with reliability on the place that
can bear the weight of this unit sufficiently. Insufficient strength
leads to injury due to falling of the unit.
If refrigerant gas escapes during installation, ventilate the
affected area. If the refrigerant gas comes into contact with
sparks or naked flames, it will cause toxic gases to be
generated.
Carry out predetermined installation work in preparation for
strong wind such as typhoon, earthquake.
Imperfection in installation work may lead to accidents arisen
from overturn, etc.
Once installation work is completed, check that there are no
refrigerant gas in the room that can come into contact with
sparks or flames from a fan heater, stove or kitchen range,
which will cause toxic gases to be generated.
The unit must be installed in accordance with applicable national
and local regulations.
Any electrical work should only be carried out by qualified
technician and use exclusive circuits without fail.
Presence of insufficient capacity in power circuit or imperfection
in execution leads to electric shock, fire, etc.
When performing piping work do not mix air except for specified
refrigerant (R410A) in refrigeration cycle. It causes capacity
down, and risk of explosion and injury due to high tension inside
the refrigerant cycle.
40
CS-F18DTE5 CU-L34DBE5 /
Page of 127
Display

Click on the first or last page to see other CS-F18DTE5 / CU-L34DBE5 service manuals if exist.