Page 61 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
10.3 
TABLE: insulation resistance measurements 
Insulation resistance R between: 
R (M
Required min. R (M
Different polarity of parts directly connected to mains (BI) 
> 20 
Primary and secondary (RI) 
> 40 
Primary and plastic enclosure (RI) 
> 40 
Primary and metal enclosure (RI) 
> 40 
Transformer (DT1) primary and core (RI) 
> 40 
Transformer (T1) primary and core (BI) 
> 20 
Transformer (T1) secondary and core (SI) 
> 20 
Transformer (T2) primary and core (BI) 
> 20 
Transformer (T2) secondary and core (SI) 
> 20 
Two layer of insulation tape (RI) 
> 40 
Note: 
1. 
BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation. 
2. 
The core of swtich transformer (DT1) is considered as secondary. 
3. 
The core of swtich transformer (T1, T2) is considered as free body. 
4. 
A force of 2 N is applied to the internal components and 30 N is applied to the enclosure for 
measuring. 
5. 
CTI<400 
 
10.3 
TABLE: dielectric strength measurements 
Test voltage applied between: 
Test voltage (Vac) 
Breakdown 
Different polarity of parts directly connected to mains (BI) 
2120 
No 
Primary and secondary (RI) 
4240 
No 
Primary and plastic enclosure (RI) 
4240 
No 
Primary and metal enclosure (RI) 
4240 
No 
Transformer (DT1) primary and core (RI) 
4240 
No 
Transformer (T1) primary and core (BI) 
2120 
No 
Transformer (T1) secondary and core (SI) 
2120 
No 
Transformer (T2) primary and core (BI) 
2120 
No 
Transformer (T2) secondary and core (SI) 
2120 
No 
Two layer of insulation tape (RI) 
4240 
No 
Note: 
1. 
BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation. 
2. 
The core of swtich transformer (DT1) is considered as secondary. 
3. 
The core of swtich transformer (T1, T2) is considered as free body. 
4. 
A force of 2 N is applied to the internal components and 30 N is applied to the enclosure for 
measuring. 
5. 
CTI<400 
 
 
 
 
Page 62 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage  ............. :  Rated voltage: 120 Vac for 
Model SUB140P 
220-240 Vac for Model 
SUB140P/230 
Test voltage: 264 Vac 
— 
 
Ambient temperature (
o
C)  ...................................... :   24~27 °C         
— 
No. 
component 
No. 
fault 
test 
voltage 
(Vac) 
test time 
fuse 
No. 
input 
current 
(A) 
result 
BR1 Pin2 to 
Pin 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
C1 
264 
< 1 Sec 
F1 
> 5.25 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Current fuse opened with > 2.1 
times fuse current. 
DT1 (Pin 9 to 
Pin 8) 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
DT1 (Pin 3 to 
Pin 1) 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
Q6 (Pin G to 
Pin D) 
264 
< 1 Sec 
F1 
> 5.25 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Current fuse opened with > 2.1 
times fuse current. 
 
 
 
 
Page 63 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
11.2 
(cont.) 
TABLE: summary of fault condition tests 
No. 
component 
No. 
fault 
test 
voltage 
(Vac) 
test time 
fuse 
No. 
input 
current 
(A) 
result 
Q6 (Pin D to 
Pin S) 
264 
< 1 Sec 
F1 
> 5.25 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Current fuse opened with > 2.1 
times fuse current. 
Q6 (Pin G to 
Pin S) 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
Q7 Pin G to 
Pin D 
264 
< 1 Sec 
F1 
> 5.25 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Current fuse opened with > 2.1 
times fuse current. 
Q7 Pin D to 
Pin S 
264 
< 1 Sec 
F1 
> 5.25 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Current fuse opened with > 2.1 
times fuse current. 
10 
Q7 Pin G to 
Pin S 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
11 
T2 Pin9 to 
Pin10 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
 
 
 
 
Page 64 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
11.2 
(cont.) 
TABLE: summary of fault condition tests 
No. 
component 
No. 
fault 
test 
voltage 
(Vac) 
test time 
fuse 
No. 
input 
current 
(A) 
result 
12 
T2 Pin7 to 
Pin10 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
13 
U1 Pin5 to 
Pin2 
264 
< 1 Sec 
F1 
> 5.25 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Current fuse opened with > 2.1 
times fuse current. 
14 
T1 Pin5 to 
Pin4 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
15 
T1 Pin3 to 
Pin4 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
16 
T1 Pin2 to 
Pin1 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
17 
T1 Pin8 to 
Pin9 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 