JBL SUB 140P EMC - CB Certificate ▷ View online
Page 61 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (M
Ω
)
Required min. R (M
Ω
)
Different polarity of parts directly connected to mains (BI)
> 20
2
Primary and secondary (RI)
> 40
4
Primary and plastic enclosure (RI)
> 40
4
Primary and metal enclosure (RI)
> 40
4
Transformer (DT1) primary and core (RI)
> 40
4
Transformer (T1) primary and core (BI)
> 20
2
Transformer (T1) secondary and core (SI)
> 20
2
Transformer (T2) primary and core (BI)
> 20
2
Transformer (T2) secondary and core (SI)
> 20
2
Two layer of insulation tape (RI)
> 40
4
Note:
1.
1.
BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation.
2.
The core of swtich transformer (DT1) is considered as secondary.
3.
The core of swtich transformer (T1, T2) is considered as free body.
4.
A force of 2 N is applied to the internal components and 30 N is applied to the enclosure for
measuring.
measuring.
5.
CTI<400
10.3
TABLE: dielectric strength measurements
P
Test voltage applied between:
Test voltage (Vac)
Breakdown
Different polarity of parts directly connected to mains (BI)
2120
No
Primary and secondary (RI)
4240
No
Primary and plastic enclosure (RI)
4240
No
Primary and metal enclosure (RI)
4240
No
Transformer (DT1) primary and core (RI)
4240
No
Transformer (T1) primary and core (BI)
2120
No
Transformer (T1) secondary and core (SI)
2120
No
Transformer (T2) primary and core (BI)
2120
No
Transformer (T2) secondary and core (SI)
2120
No
Two layer of insulation tape (RI)
4240
No
Note:
1.
1.
BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation.
2.
The core of swtich transformer (DT1) is considered as secondary.
3.
The core of swtich transformer (T1, T2) is considered as free body.
4.
A force of 2 N is applied to the internal components and 30 N is applied to the enclosure for
measuring.
measuring.
5.
CTI<400
Page 62 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. : Rated voltage: 120 Vac for
Model SUB140P
220-240 Vac for Model
SUB140P/230
SUB140P/230
Test voltage: 264 Vac
—
Ambient temperature (
o
C) ...................................... : 24~27 °C
—
No.
component
No.
fault
test
voltage
(Vac)
test time
fuse
No.
input
current
(A)
result
1
BR1 Pin2 to
Pin
S
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
2
C1
B
264
< 1 Sec
F1
> 5.25
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Current fuse opened with > 2.1
times fuse current.
3
DT1 (Pin 9 to
Pin 8)
S
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
4
DT1 (Pin 3 to
Pin 1)
S
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
5
Q6 (Pin G to
Pin D)
S
264
< 1 Sec
F1
> 5.25
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Current fuse opened with > 2.1
times fuse current.
Page 63 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
11.2
(cont.)
(cont.)
TABLE: summary of fault condition tests
P
No.
component
No.
fault
test
voltage
(Vac)
test time
fuse
No.
input
current
(A)
result
6
Q6 (Pin D to
Pin S)
S
264
< 1 Sec
F1
> 5.25
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Current fuse opened with > 2.1
times fuse current.
7
Q6 (Pin G to
Pin S)
S
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
8
Q7 Pin G to
Pin D
S
264
< 1 Sec
F1
> 5.25
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Current fuse opened with > 2.1
times fuse current.
9
Q7 Pin D to
Pin S
S
264
< 1 Sec
F1
> 5.25
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Current fuse opened with > 2.1
times fuse current.
10
Q7 Pin G to
Pin S
S
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
11
T2 Pin9 to
Pin10
O
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
Page 64 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
11.2
(cont.)
(cont.)
TABLE: summary of fault condition tests
P
No.
component
No.
fault
test
voltage
(Vac)
test time
fuse
No.
input
current
(A)
result
12
T2 Pin7 to
Pin10
O
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
13
U1 Pin5 to
Pin2
S
264
< 1 Sec
F1
> 5.25
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Current fuse opened with > 2.1
times fuse current.
14
T1 Pin5 to
Pin4
S
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
15
T1 Pin3 to
Pin4
S
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
16
T1 Pin2 to
Pin1
S
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
17
T1 Pin8 to
Pin9
O
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
Click on the first or last page to see other SUB 140P service manuals if exist.