DOWNLOAD JBL SUB 140P Service Manual ↓ Size: 2.06 MB | Pages: 87 in PDF or view online for FREE

Model
SUB 140P
Pages
87
Size
2.06 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-140p.pdf
Date

JBL SUB 140P EMC - CB Certificate ▷ View online

 
 
 
 
Page 65 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
11.2 
(cont.) 
TABLE: summary of fault condition tests 
No. 
component 
No. 
fault 
test 
voltage 
(Vac) 
test time 
fuse 
No. 
input 
current 
(A) 
result 
18 
U2 Pin1 to 
Pin2 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
19 
U2 Pin3 to 
Pin4 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
20 
CN4 Pin1 to 
Pin2 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
21 
CN2 Pin1 to 
Pin2 
264 
10 min. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
22 
CN2 Pin2 to 
Pin3 
264 
< 1 Sec 
F1 
> 5.25 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Current fuse opened with > 2.1 
times fuse current. 
23 
DT1 Pin9 to 
CN3 Pin6 
O/L 
264 
9 hr. 
F1 
0.29 to 
0.32 to 
0.06 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Shut down, when load to 0.11 A 
 
 
 
 
Page 66 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
11.2 
(cont.) 
TABLE: summary of fault condition tests 
No. 
component 
No. 
fault 
test 
voltage 
(Vac) 
test time 
fuse 
No. 
input 
current 
(A) 
result 
24 
T2 Pin10 toT2 
Pin9 after D8 
O/L 
264 
10 hr. 
F1 
0.29 to 
1.26 to 
0.06 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Shut down, when load to 3 A 
25 
T1 Pin4 to 
Pin5 after D1 
O/L 
264 
10 hr. 
F1 
0.29 to 
0.34 to 
0.06 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Shut down, when load to 1 A 
26 
T1 Pin4 to 
Pin3 after D9 
O/L 
264 
9.5 hr. 
F1 
0.29 to 
0.55 to 
0.06 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Shut down, when load to 1.2 A 
27 
T1 Pin4 to 
Pin2 after D4 
O/L 
264 
9.5 hr. 
F1 
0.29 to 
0.57 to 
0.06 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Shut down, when load to 0.5 A 
28 
U2 Pin1 
O/L 
264 
30 mins 
F1 
0.29 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Normal operation, no hazard. 
29 
Ventilation 
openings 
264 
2 hr. 
F1 
0.29 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Normal operation, no hazard. 
30 
Ventilation 
openings 
132 
1 hr. 
F1 
0.52 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Normal operation, no hazard. 
 
 
 
 
Page 67 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
11.2 
(cont.) 
TABLE: summary of fault condition tests 
No. 
component 
No. 
fault 
test 
voltage 
(Vac) 
test time 
fuse 
No. 
input 
current 
(A) 
result 
31 
Output power 
Max. 
253 
3 hr. 
F1 
0.29 to 
0.06 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down, No hazards. 
32 
Output power 
Max. 
132 
4 hr. 
F1 
0.52 to 
0.06 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down, No hazards. 
33 
T2 
(NT1810NL) 
Pin 10 to T2 
Pin 9, after D8 
O/L 
264 
11 hr. 
F1 
0.24 to 
0.59 to 
0.06 
Transformer coil temp. rise: -- K 
Clause 9: Pass 
Hi-pot: Pass 
Shut down, when load to 2.0 A 
34 
T2 
(NT1810NL) 
Pin 9 to T2 
Pin 10 
264 
10 min. 
F1 
0.24 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
35 
T2 
(NT1810NL) 
Pin 7 to T2 
Pin 10 
264 
10 min. 
F1 
0.24 to 
0.06 
Transformer coil temp. rise: - K 
Clause 9: Pass 
Hi-pot: Pass 
Unit shut down immediately, No 
hazards. 
supplementary information 
Note: 
1)  S: Short-circuited; O: Open-circuited; L: Locked 
 
 
 
 
 
Page 68 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
14 
TABLE: list of critical components and materials 
Component 
Manufacturer/ 
trademark 
Type/model 
Value/rating 
Standard 
Approval/ 
reference 
1)
 
Wooden 
enclosure 
various 
various 
Min. 17.5 mm 
thickness 
IEC 60065 
applicable part 
Tested in 
appliance 
Metal enclosure  various 
various 
Min. 2.5 mm 
thickness 
IEC 60065 
applicable part 
Tested in 
appliance 
Speaker 
various 
various 
4 ohms, 50W 
IEC 60065 
applicable part 
Tested in 
appliance 
Plug 
I-Sheng 
SP-021A 
2.5A, 250V 
IEC 60083 
EN 50075 
DIN VDE 0620 
VDE, S 
Alt. 
various 
various 
2.5A, 250V 
IEC 60083 
EN 50075 
DIN VDE 0620 
VDE, S 
Power cord 
I-Sheng 
H03VV-F 
2
×
0.75mm
2
 
IEC 60227 
VDE, S 
Alt. 
various 
H03VV-F 
2
×
0.75mm
2
 
IEC 60227 
VDE, S 
Strain Relief 
Bushing 
Heavy Power 
4K-4 
3.8 mm by 7.6 
mm 
IEC 60065 
applicable part 
Tested in 
appliance 
Power Switch 
Chily 
3024 
16, 250 Vac, 
10E
3
 Cycles 
IEC 61058-1 
VDE 
Primary wire 
various 
UL style 1617 or 
1672 
300 V, VW-1, 18 
AWG, 105 
°
IEC 60065 
applicable part 
Tested in 
appliance 
Primary 
Connector (CN1) 
Weli Sheng 
Px-I39606, 
Mx-I39606 
7A, 250V 
IEC 61984 
TUV 
Fuse (F1) (For 
SUB140P used 
only)  
Walter 
2010 Series 
T4.0A , 250V 
IEC 60127-3 
VDE 
Fuse (F1) (For 
SUB140P/230 
used only)  
Walter 
2010 Series 
T2.5A , 250V 
IEC 60127-3 
VDE 
 
Page of 87
Display

Click on the first or last page to see other SUB 140P service manuals if exist.