JBL SUB 140P EMC - CB Certificate ▷ View online
Page 65 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
11.2
(cont.)
(cont.)
TABLE: summary of fault condition tests
P
No.
component
No.
fault
test
voltage
(Vac)
test time
fuse
No.
input
current
(A)
result
18
U2 Pin1 to
Pin2
O
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
19
U2 Pin3 to
Pin4
S
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
20
CN4 Pin1 to
Pin2
S
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
21
CN2 Pin1 to
Pin2
S
264
10 min.
F1
0.29 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
22
CN2 Pin2 to
Pin3
S
264
< 1 Sec
F1
> 5.25
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Current fuse opened with > 2.1
times fuse current.
23
DT1 Pin9 to
CN3 Pin6
O/L
264
9 hr.
F1
0.29 to
0.32 to
0.32 to
0.06
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Shut down, when load to 0.11 A
Page 66 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
11.2
(cont.)
(cont.)
TABLE: summary of fault condition tests
P
No.
component
No.
fault
test
voltage
(Vac)
test time
fuse
No.
input
current
(A)
result
24
T2 Pin10 toT2
Pin9 after D8
O/L
264
10 hr.
F1
0.29 to
1.26 to
1.26 to
0.06
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Shut down, when load to 3 A
25
T1 Pin4 to
Pin5 after D1
O/L
264
10 hr.
F1
0.29 to
0.34 to
0.34 to
0.06
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Shut down, when load to 1 A
26
T1 Pin4 to
Pin3 after D9
O/L
264
9.5 hr.
F1
0.29 to
0.55 to
0.55 to
0.06
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Shut down, when load to 1.2 A
27
T1 Pin4 to
Pin2 after D4
O/L
264
9.5 hr.
F1
0.29 to
0.57 to
0.57 to
0.06
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Shut down, when load to 0.5 A
28
U2 Pin1
O/L
264
30 mins
F1
0.29
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Normal operation, no hazard.
29
Ventilation
openings
B
264
2 hr.
F1
0.29
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Normal operation, no hazard.
30
Ventilation
openings
O
132
1 hr.
F1
0.52
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Normal operation, no hazard.
Page 67 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
11.2
(cont.)
(cont.)
TABLE: summary of fault condition tests
P
No.
component
No.
fault
test
voltage
(Vac)
test time
fuse
No.
input
current
(A)
result
31
Output power
Max.
253
3 hr.
F1
0.29 to
0.06
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Unit shut down, No hazards.
32
Output power
Max.
132
4 hr.
F1
0.52 to
0.06
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Unit shut down, No hazards.
33
T2
(NT1810NL)
Pin 10 to T2
Pin 9, after D8
O/L
264
11 hr.
F1
0.24 to
0.59 to
0.59 to
0.06
Transformer coil temp. rise: -- K
Clause 9: Pass
Hi-pot: Pass
Shut down, when load to 2.0 A
34
T2
(NT1810NL)
Pin 9 to T2
Pin 10
S
264
10 min.
F1
0.24 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
35
T2
(NT1810NL)
Pin 7 to T2
Pin 10
S
264
10 min.
F1
0.24 to
0.06
Transformer coil temp. rise: - K
Clause 9: Pass
Hi-pot: Pass
Unit shut down immediately, No
hazards.
supplementary information
Note:
1) S: Short-circuited; O: Open-circuited; L: Locked
Page 68 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
14
TABLE: list of critical components and materials
P
Component
Manufacturer/
trademark
trademark
Type/model
Value/rating
Standard
Approval/
reference
reference
1)
Wooden
enclosure
various
various
Min. 17.5 mm
thickness
IEC 60065
applicable part
Tested in
appliance
Metal enclosure various
various
Min. 2.5 mm
thickness
IEC 60065
applicable part
Tested in
appliance
Speaker
various
various
4 ohms, 50W
IEC 60065
applicable part
Tested in
appliance
Plug
I-Sheng
SP-021A
2.5A, 250V
IEC 60083
EN 50075
DIN VDE 0620
VDE, S
Alt.
various
various
2.5A, 250V
IEC 60083
EN 50075
DIN VDE 0620
VDE, S
Power cord
I-Sheng
H03VV-F
2
×
0.75mm
2
IEC 60227
VDE, S
Alt.
various
H03VV-F
2
×
0.75mm
2
IEC 60227
VDE, S
Strain Relief
Bushing
Bushing
Heavy Power
4K-4
3.8 mm by 7.6
mm
mm
IEC 60065
applicable part
Tested in
appliance
Power Switch
Chily
3024
16, 250 Vac,
10E
3
Cycles
IEC 61058-1
VDE
Primary wire
various
UL style 1617 or
1672
300 V, VW-1, 18
AWG, 105
°
C
IEC 60065
applicable part
Tested in
appliance
Primary
Connector (CN1)
Weli Sheng
Px-I39606,
Mx-I39606
7A, 250V
IEC 61984
TUV
Fuse (F1) (For
SUB140P used
only)
Walter
2010 Series
T4.0A , 250V
IEC 60127-3
VDE
Fuse (F1) (For
SUB140P/230
used only)
Walter
2010 Series
T2.5A , 250V
IEC 60127-3
VDE